DESCRIPTION MLH Series pressure sensors combine Application Specific Integrated Circuit (ASIC) technology with a media isolated, metal diaphragm design. This digitally compensated sensor offers value and performance, making it the ideal pressure sensing solution for demanding applications. Fully temperature compensated, calibrated and amplified, the MLH is available in 50 psi to 8,000 psi pressure ranges. The MLH has six standard output options: A. 0.5 Vdc to 4.5 Vdc ratiometric from 5 Vdc excitation B. 4 mA to 20 mA C. 1 Vdc to 6 Vdc regulated D. 0.25 Vdc to 10.25 Vdc regulated E. 0.5 Vdc to 4.5 Vdc regulated G. 1 Vdc to 5 Vdc regulated MLH sensors deliver 0.25% full scale accuracy Best Fit Straight Line (BFSL) and as low as 2% total error over a temperature range of -40 C to 125 C [-40 F to 257 F]. Industry standard connectors and process ports are offered for enhanced reliability and user flexibility. FEATURES All metal wetted parts for use in wide variety of fluid applications No internal elastomeric seals mean no o-ring compatibility issues Amplified outputs eliminate cost of external amplifiers Input reverse voltage protection guards against mis-wiring Less than 2 ms response time provides accurate, high speed measurement Rated IP65 or better for protection from harsh environments POTENTIAL APPLICATIONS Compressors Refrigeration and HVAC/R General industrial General hydraulics Multiple transportation applications including braking and alternate fuels Medical Table 1. Pressure Range Specifications1 (At 25 C [77 F] and at rated excitation unless otherwise specified.) psi Pressure 50 100 150 200 Proof pressure 150 300 450 600 Burst pressure 500 1000 1500 2000 250 300 500 1000 2000 750 900 1500 2000 4000 2500 3000 5000 10000 20000 3000 5000 8000 6000 7500 12000 30000 30000 30000 bar Pressure 6 10 16 25 40 60 100 160 250 350 500 550 Proof pressure 18 30 48 75 80 120 200 320 500 700 750 825 Burst pressure 60 100 160 250 400 600 1000 1600 2068 2068 2068 2068 Note: 1. Comparable metric units follow same proof and burst specifications. Table 2. Physical and Environmental Specifications Parameter Characteristic Material in contact with media port: stainless steel 304L; diaphragm: Haynes 214 alloy Housing material black plastic - Amodel AS-4133 HS - PPA Weight 57.0 g [2.0 oz] (typical for Delphi Metri-Pack 150 and 1/8 NPT port) Shock 100 g peak [11 ms] Vibration MIL-STD-810C, Figure 514.2-5, Curve AK, Table 514.2-V, Random Vibration Test [overall g rms = 20.7 min.] Compensated and operating temperature range: 0.5 Vdc to 4.5 Vdc ratiometric output -40 C to 125 C [-40 F to 257 F] all regulated and 4 mA to 20 mA outputs -40 C to 125 C [-40 F to 257 F] See Figures 2 and 3 for operating area details. Storage temperature range -40 C to 125 C [-40 F to 257 F] Approvals UL Component Recognition for USA and Canada: File No. E258956 Table 3. Electrical Specifications (At 25 C [77 F] and at rated excitation unless otherwise specified.) Ratiometric (A) Current (B) Regulated (C) Regulated (D) Regulated (E) Regulated (G) Zero output 0.5 Vdc 4 mA 1 Vdc 0.25 Vdc 0.5 Vdc 1 Vdc Full scale span (FSS) 4 Vdc (0.5 Vdc to 4.5 Vdc) 16 mA (4 mA to 20 mA) 5 Vdc (1 Vdc to 6 Vdc) 10 Vdc (0.25 Vdc to 10.25 Vdc) 4 Vdc (0.5 Vdc to 4.5 Vdc) 4 Vdc (1 Vdc to 5 Vdc) Excitation 5 Vdc (6 Vdc max.)1 9.5 Vdc to 30 Vdc2 8 Vdc to 30 Vdc2 14 Vdc to 30 Vdc2 7 Vdc to 30 Vdc2 8 Vdc to 30 Vdc2 Supply current 4 mA typ. (8 mA max.) N/A 5 mA typ. (17 mA max.) 5 mA typ. (17 mA max.) 5 mA typ. (17 mA max.) 5 mA typ. (17 mA max.) Source (nominal) 1 mA N/A 1 mA 1 mA 1 mA 1 mA Sink (nominal) 1 mA at zero output N/A 1 mA at zero output 1 mA at zero output 1 mA at zero output 1 mA at zero output 90 dB 90 dB 90 dB 90 dB 90 dB 90 dB Parameter Supply rejection ratio Output impedance 25 max. N/A 25 max. 25 max. 25 max. Notes: 1. Maintains ratiometricity at 5 0.25 Vdc excitation. Product can tolerate 6 Vdc excitation without damage. 2. See Figures 2 and 3 for more information regarding maximum excitation voltage vs. operating temperature. 2 www.honeywell.com/sensing 25 max. Table 4. Performance Specifications (At 25 C [77 F] and at rated excitation unless otherwise specified.) Parameter Characteristic Response time 2 ms Accuracy1: >100 psi 0.25% FSS <100 psi 0.50% FSS Total error band2: Gage: <300 psig 3% FSS >300 psig 2% FSS Seal gage: >300 psis 2% FSS Seal gage without L, M, P termination: 100 psis to 299 psis (-40 C to 85 C [-40 F to 185 F]) 3% FSS 100 psis to 299 psis (>85 C to 125 C [>185 F to 257 F]) 10% FSS >300 psis (-40 C to 125 C [-40 F to 257 F]) 2% FSS Seal gage with L, M, P termination: 100 psis to 299 psis (-40 C to 65 C [-40 F to 149 F]) 10% FSS 100 psis to 299 psis (>65 C to 125 C [>149 F to 257 F]) 15% FSS >300 psis (-40 C to 65 C [-40 F to 149 F]) 5% FSS >300 psis (>65 C to 125 C [>149 F to 257 F]) 15% FSS Notes: 1. Includes pressure non-linearity (BFSL), pressure hysteresis and non-repeatability. Thermal errors are not included. 2. Includes zero error, span error, thermal effect on zero, thermal effect on span, thermal hysteresis, pressure-non-linearity, pressure hysteresis and non-repeatability. 125 124 123 122 121 120 119 118 117 116 Figure 3. Operating and Temperature Compensated Area for 4 mA to 20 mA Output Operating Temperature (C) Operating Temperature (C) Figure 2. Operating and Temperature Compensated Area for All Regulated Output Options Operating and Temperature Compensated Area for Regulated Output 6 8 10 12 14 16 18 20 22 24 Supply Voltage (Vdc) 26 28 30 Note: The dashed line indicates the operating and temperature compensated area with a 24 V supply. 125 120 115 110 105 100 95 90 85 80 75 70 65 60 10 Ohm Load 250 Ohm Load Operating and Temperature Compensated Area for 4 mA to 20 mA Output 6 8 10 12 14 16 18 20 22 Supply Voltage (Vdc) 24 26 28 30 Note: The operating area is extended with a 250 Ohm resistor. Higher loads extend the operating area. The dashed line indicates the operating and temperature compensated area with a 24 V supply using a 250 Ohm load. Figure 4. Mounting Dimensions (For reference only. mm/(in).) Pin and Wire Codes (Option B - Packard) Pin Voltage Current a + excitation + excitation b output - excitation c common no connection A variety of pressure ports and electrical termination connection options are available. Refer to the "How to Order" on previous page for possible combinations. Contact your Honeywell representative for details. Honeywell Sensing and Control 3 Nomenclature and Order Guide1 MLH _ _ _ _ _ psi 050 500 100 01K 150 02K 200 03K 250 05K 300 08K _ Output Signal A = 0.5 Vdc to 4.5 Vdc ratiometric from 5 Vdc excitation B = 4 mA to 20 mA C = 1 Vdc to 6 Vdc regulated D = 0.25 Vdc to 10.25 Vdc regulated E = 0.5 Vdc to 4.5 Vdc regulated G = 1 Vdc to 5 Vdc regulated Series Pressure Range _ __ bar 006 100 010 160 016 250 025 350 040 500 060 550 Unit P = psi B = bar Measurement Type G = Gage (psi) S = Sealed gage (psi)4 Electrical Termination B = Delphi Metri-Pack 150 C = Hirschmann (mates with G4W1F) D = M12 x 1 (Brad Harrison micro) G = DIN 43650-C, 8 mm-male H = Amp Superseal 1.52 L = Cable (1 m) M = Cable (3 m) P = Flying leads (20 AWG - 6 in) T = Deutsch DTM04-3P (integral) (Mating connectors are not supplied.) Pressure 01 = 1/4-18 NPT Connection 02 = M12 x 1.5 (ISO 6149)3 03 = M14 x 1.5 (ISO 6149)3 04 = 3/8-24 UNF (SAE-3 O-ring boss)3 05 = M18 x 1.5 (ISO 6149)3 06 = 1/8 in-27 NPT 07 = 1/2 in-20 UNF (SAE-5 O-ring boss)3 08 = M10 x 1 (ISO 6149)3 09 = 1/4 in SAE female Schrader (7/16-20 UNF-2B internal thread) 10 = 7/16-20 UNF (SAE-4 O-ring boss)3 11 = 1/2 in NPT 12 = 9/16-18 UNF (SAE-6 O-ring boss)3 13 = R 1/4-19 BSPT (ISO 7-1 tapered thread) 14 = G 1/4-19 (DIN 3852-2)3 15 = G 1/8 with O-ring groove3 16 = M16 x 1.5 (ISO 6149)3 17 = G 1/4 with O-ring groove3 18 = G 1/8 (DIN 3852-2)3 19 = R 1/8-28 BSPT (ISO 7-1 tapered thread) 20 = M20 x 1.5 (ISO 6149)3 21 = 1/2-20 (SAE J514)3 WARNING WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com/sensing Notes: 1. Not all combinations are available. Minimum quantity orders apply. Additional pressure ranges, port styles and special calibration versions are available. Contact your local sales representative for assistance. 2. Available with "A" output only. 3. Supplied with O-ring. 4. Sealed gage devices are not available for pressure ranges below 100 psi. 008118-7-EN IL50 GLO Printed in USA February 2011 Copyright (c) 2011. Honeywell International Inc. All rights reserved.