www.recom-power.com REV.: 1/2018 PA-6
AC/DC Converter
Specifications (measured at Ta= 25°C, nominal input voltage, full load otherwise noted)
RAC01-C
RAC02-C
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
Information Technology Equipment - General Requirments for Safety 1606038 EN60950-1:2006 + A2:2013
IEC60950-1:2005, 2nd Edition + A2:2013
Information Technology Equipment - General Requirments for Safety (CB Scheme) L0339m10-CB-1-B1
IEC60950-1:2005, 2nd Edition + A2:2013
Information Technology Equipment, General Requirements for Safety E224736-A5 UL60950-1, 2nd Edition, 2007
CSA C22.2 60950-1, 2nd Edition, 2007
Household and similar electrical appliances - Safety - Part 1: General requirements (10)
L0339L26-B2-L EN60335-1:2012 + A11:2014
EAC Safety of Low Voltage Equipment RU-AT.49.09571 TP TC 004/2011
RoHS2 RoHS-2011/65/EU + AM-2015/863
EMC Compliance (Industrial) Condition Standard / Criterion
Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55032:2015
Information technology equipment - Immunity characteristics - Limits and methods
of measurement EN55024:2010 + A1:2015
ESD Electrostatic discharge immunity test ±8kV air, ±4kV contact IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1.0kV IEC61000-4-4:2012, Criteria A
Surge Immunity AC Power Port: L-N ±1.0kV IEC61000-4-5:2005, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3Vr.m.s. IEC61000-4-6:2008, Criteria A
Voltage Dips and Interruptions Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria C
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
EMC Compliance (Household) only 2Watt version Condition Standard / Criterion
Electromagnetic compatibility - Requirements for household appliances, electric
tools and similar apparatus - Part 1: Emission EN55014-1:2006+A2:2011
Information technology equipment - Immunity characteristics - Limits and methods
of measurement EN55014-2:2015
ESD Electrostatic discharge immunity test ±8kV air, ±4kV contact IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test 3V/m IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity AC Power Port: ±1kV
DC Output: ±0.5kV EC61000-4-4:2012, Criteria A
Surge Immunity AC Power Port:L to N ±2kV
DC Output: L to N ±1kV IEC61000-4-5:2014, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields
3 Vr.m.s. IEC61000-4-6:2013, Criteria A
Voltage Dips and Interruptions Voltage Dips >95%
Voltage Dips 30%
Voltage Interruptions >95%
IEC61000-4-11:2004, Criteria B
IEC61000-4-11:2004, Criteria C
IEC61000-4-11:2004, Criteria C
Limits of Harmonic Current Emissions EN61000-3-2:2014
Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013
Notes:
Note10: RAC01-C series is excluded