FRS1A........FRS1M
Current
1.0 A
Voltage
50 V to 1000 V
MECHANICAL DATA
DO-214AC (SMA)

Ideal for automated placement
Low profile package
Low power losses, high efficiency
1.0 Amp. Surface Mounted Glass Passivated Fast Recovery Rectifier
TYPICAL APPLICATIONS
FEATURES
High surge current capability
Solder dip 260ºC, 10s
Component in accordance to RoHS 2011/65/EU
and WEEE 2002/96/EC
Maximum Ratings and Electrical Characteristics at 25 ºC
Meets MSL level 1, per J-STD-020, LF maximum
peak of 260º C
Cavity-free glass-passivated junction
Low forward voltage drop
Fast switching for high efficiency
For use in fast switching rectification of power supply,
inverters, converters, and freewheeling diodes for consumer,
and telecommunication.
AEC
-Q101 qualified
Maximum Recurrent Peak Reverse Voltage (V)
Maximum RMS Voltage (V)
Maximum DC Blocking Voltage (V)
V
RRM
V
RMS
V
DC
I
F(AV)
Marking Code
Typical Junction Capacitance (1MHz; -4V)
C
j
Temperature Range
1.0 A
27 °C/W
75 °C/W
30 A
250 ns
I
FSM
V
F
I
R
Maximum Instantaneous Forward Voltage at 1.0 A
Maximum Reverse Recovery Time (0.5/1/0.25A)
T
rr
1.3 V
8 pF
150 ns 500 ns
-55 to + 150 °C
FRS1G
F4
280
400
FRS1D
F3
140
200
FRS1J
F5
420
600
FRS1K
F6
560
800
FRS1M
F7
700
1000
400200 600 800 1000
5 µA
50 µA
FRS1B
F2
70
100
FRS1A
F1
35
50
10050
Typical thermal resistance
(5x5 mm
2
x 130 µm Copper Area)
Rth (j-a)
Rthj-l
Operating Junction and Storage
T
j
- T
stg
Forward current at T
L
= 110 °C
8.3 ms. peak forward surge current
(Jedec Method)
Maximum DC Reverse Current
at Rated DC Blocking Voltage
Tj = 25 °C
Tj = 125 °C
R
www.fagorelectronica.com
Document Name: frs1 Version: May-16
Page Number: 1/4

Case: DO-214AC (SMA). Epoxy meets UL 94V-0
flammability rating.

Polarity: Color band denotes cathode end.

Terminals:
Matte tin plated leads, solderable per
MIL-STD-750 Method 2026, J-STD-002 and JESD22-B102.
Consumer grade, meets JESD 201 class 1A whisker test
Revision: 1

HE3 suffix
for high reliability grade, meets JESD 201
class 2 whisker test.
Package Outline Dimensions
:
(mm)
FRS1A........FRS1M
1.0 Amp. Surface Mounted Glass Passivated Fast Recovery Rectifier
Ordering information
TRTB 13" diameter tape and reel 7,500 0.060
FRS1J TRTB
DO-214AC (SMA)
TRTB 13" diameter tape and reel 7,500 0.060
FRS1J HE3 TRTB
www.fagorelectronica.com
Document Name: frs1 Version: May-16
Page Number: 2/4
PREFERRED P/N PACKAGE CODE DELIVERY MODE BASE QUANTITY UNIT WEIGHT (g)
5.1
±0.3
1.05
±0.2
1.25
±0.25
2.2
±0.3
0.15
±0.1
0.2
+0.1
-0.05
1.4
+0.2
-0.1
2.6
±0.3
2
2
4.2
1.25
±0.25
Year code
Marking code
Week code
Mounting Pad Layout
MC
WW
Y
Revision: 1
FRS1A........FRS1M
Ratings and Characteristics (Ta 25 ºC unless otherwise noted)
1.0 Amp. Surface Mounted Glass Passivated Fast Recovery Rectifier
FORWARD CURRENT DERATING CURVE
Lead temperature (ºC)
0 50 17525 75 150125100
1.4
1.2
1
0.8
0.6
0.4
0.2
0
F(AV)
I , average forward rectified current (A)
5x5mm2 x 130 mm
Thick Copper Land Areas
TYPICAL REVERSE CHARACTERISTIC
20 60
10
IR, Reverse current (mA)
Percent of rated peak
reverse voltage
1
0.1
0.01
40 80 100 120
T = 25 ºC
j
T = 75 ºC
j
T = 125 ºC
j
MAXIMUM NON REPETITIVE
PEAK FORWARD SURGE CURRENT
1
Number of cycles at 60 Hz
2 4 6 10 1004020
30
25
20
15
10
5
I , peak forward surge current (A)
FSM
TYPICAL JUNCTION
CAPACITANCE
0.1 0.4 1.0 10 40 100
1
4
6
8
4
20
10
Cj , junction capacitance (pF)
2
T = 25 ºC
j
f = 1 MHz
TYPICAL FORWARD CHARACTERISTIC
0.6 0.8 1 1.2 1.4 1.6
10
I , instantaneous forward current (A)
F
V
F
, instantaneous forward
voltage (V)
T = 25 ºC
j
2
1
0.2
0.1
0.01
V
R
, reverse voltage (V)
www.fagorelectronica.com
Document Name: frs1
Version: May-16
Page Number: 3/4
Revision: 1
FRS1A........FRS1M
Disclaimer
1.0 Amp. Surface Mounted Glass Passivated Fast Recovery Rectifier
0
15-Feb-2013 Original Data Sheet
1
2-May-2016 Included HE3
www.fagorelectronica.com
Document Name: frs1 Version: May-16
Page Number: 4/4
All product, product specifications and data are subject to change without notice to improve reliability,
function or design or otherwise.
Fagor Electrónica, S.Coop., its affiliates, agents, and employees, and all persons acting on its or their
behalf (collectively, "Fagor"), disclaim any and all liability for any errors, inaccuracies or incompleteness contained
in any datasheet or in any other disclosure relating to any product.
Fagor makes no warranty, representation or guarantee regarding the suitability of the products for any particular
purpose or the continuing production of any product. To the maximum extent permitted by applicable law,
Fagor disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all
liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied
warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Fagor's knowledge
of typical requirements that are often placed on Fagor products in generic applications. Such statements are not
binding statements about the suitability of products for a particular application. It is the customer's responsibility
to validate that a particular product with the properties described in the product specification is suitable for use in a
particular application. Parameters provided in datasheets and/or specifications may vary in different applications
and performance may vary over time. All operating parameters, including typical parameters, must be validated
for each customer application by the customer's technical experts. Product specifications do not expand or
otherwise modify Fagor's terms and conditions of purchase, including but nos limited to the warranty expressed
therein.
Except as expressly indicated in writing. Fagor products are not designed for use in medical, life-saving, or
life-sustaining applications or for any other application in which the failure of the Fagor product could result in
personal injury or death. Customers using or selling Fagor products not expressly indicated for use in such
applications do so at their own risk and agree to fully indemnify and hold Fagor and its distributors harmless from
and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use
or sale, including attomeys fees, even if such claim alleges that Fagor or its distributor was negligent regarding
the design or manufacture of the part. Please contact authorized Fagor personnel to obtain written terms and
conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Fagor, Product names and markings noted herein may be trademarks of their
respective owners.
Revision: 1
Date Revision Description of Changes
Revision History