XCKJ10511H7 Product data sheet Characteristics limit switch XCKJ - thermoplastic roller lever 1NC+1NO - snap action - 1/2NPT Product availability : Stock - Normally stocked in distribution facility Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications Price* : 104.00 USD Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKJ Sensor design Form A conforming to CENELEC EN 50041 Body type Fixed Head type Rotary head Material Metal Body material Zamak Head material Zamak Fixing mode By the body Movement of operating head Rotary Type of operator Spring return roller lever thermoplastic Type of approach Lateral approach 1 or 2 programmable direction Cable entry 1 entry tapped for 1/2" NPT cable gland Number of poles 2 Contacts type and composition 1 NC + 1 NO Contact operation Snap action Complementary Switch actuation By 30 cam Electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm Contacts insulation form Zb Number of steps 1 Positive opening With Positive opening minimum torque 4.42 lbf.in (0.5 N.m) Jan 27, 2019 1 Minimum torque for tripping 2.21 lbf.in (0.25 N.m) Maximum actuation speed 4.92 ft/s (1.5 m/s) [Ie] rated operational current 3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A 0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A [Ithe] conventional enclosed thermal current 10 A [Ui] rated insulation voltage 300 V conforming to CSA C22.2 No 14 500 V degree of pollution 3 conforming to IEC 60947-1 300 V conforming to UL 508 Resistance across terminals <= 25 MOhm conforming to IEC 60255-7 category 3 [Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 Short-circuit protection 10 A by gG cartridge fuse Electrical durability 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate: <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C Mechanical durability 30000000 cycles Width 1.57 in (40 mm) Height 3.03 in (77 mm) Depth 1.73 in (44 mm) Product weight 1.06 lb(US) (0.48 kg) Terminals description ISO n1 (13-14)NO (21-22)NC Environment Shock resistance 50 gn (duration = 11 ms) conforming to IEC 60068-2-27 Vibration resistance 25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6 IP degree of protection IP66 conforming to IEC 60529 IK degree of protection IK07 conforming to EN 50102 Overvoltage category Class I conforming to NF C 20-030 Class I conforming to IEC 61140 Ambient air temperature for operation -13...158 F (-25...70 C) Ambient air temperature for storage -40...158 F (-40...70 C) Protective treatment TC Product certifications CCC CSA UL Standards CENELEC EN 50041 EN 60204-1 EN 60947-5-1 IEC 60204-1 IEC 60947-5-1 UL 508 CSA C22.2 No 14 Ordering and shipping details Category 22411 - LIMIT SWITCHES,IEC,XCKJ Discount Schedule T GTIN 00785901451563 Nbr. of units in pkg. 1 Package weight(Lbs) 1.0800000000000001 Returnability Y Country of origin FR 2 Offer Sustainability Sustainable offer status Green Premium product RoHS (date code: YYWW) Compliant - since 1136 - Schneider Electric declaration of conformity Schneider Electric declaration of conformity REACh Reference not containing SVHC above the threshold Reference not containing SVHC above the threshold Product end of life instructions Need no specific recycling operations California proposition 65 WARNING: This product can expose you to chemicals including: - - - - - - - Substance 1 Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and - - - - - - - Substance 2 Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. - - - - - - - More information For more information go to www.p65warnings.ca.gov Contractual warranty Warranty period 18 months 3 Product data sheet Dimensions Drawings Dimensions (1) 1 tapped entry 1/2" NPT 4 XCKJ10511H7 Product data sheet Mounting and Clearance XCKJ10511H7 Mounting with Cable Entry Position of Cable Gland (1) (2) Recommended To be avoided 5 Product data sheet Mounting and Clearance Mounting with Rotary Heads and Levers Type of Cam (1) (2) Recommended To be avoided 6 XCKJ10511H7 Product data sheet Mounting and Clearance XCKJ10511H7 Setting-up with Lever Head (1) (2) (a) 5 steps throughout 360 / Tightening torque (Min : 1) (Max : 1.5) 45 steps throughout 360 / Tightening torque (Min : 1) (Max : 1.5) Tightening torque (Min : 1) (Max : 1.5) 7 Product data sheet Mounting and Clearance Setting-up with Head ZCKE05 Direction of Actuation Programming 8 XCKJ10511H7 Product data sheet Connections and Schema XCKJ10511H7 Wiring Diagram 2-pole NC + NO Snap Action 9 Product data sheet Technical Description Characteristics of Actuation Switch Actuation on End 10 XCKJ10511H7 Product data sheet Technical Description XCKJ10511H7 Functionnal Diagram (P) (1) (2) (3) (4) (5) Positive opening point NC contact with positive opening operation Closed Open Tripping Resetting XCKJ10511H7 is replaced by the following group of products: Industrial range ZCKE05 limit switch head ZCKE - without lever left and right actuation Qty 1 Industrial range ZCKJ1H7 limit switch body ZCKJ - fixed - w/o display - 1NC+1NO - snap action - 1/2"NPT Qty 1 Industrial range ZCKY11 limit switch lever ZCKY - thermoplastic roller lever - -40..70C - -40..70C Qty 1 Reason for Substitution: end of life | Substitution date: 01 January 2017 11