Input
Output - Main Output
Characteristic Minimum Typical Maximum Units Notes & Conditions
Output Voltage 12 48 VDC See Models and Ratings table
Initial Set Accuracy ±1 % 50% load, 115/230 VAC
Output Voltage Adjustment % None
Minimum Load 0ANo minimum load required
Start Up Delay 2s115/230 VAC full load.
Hold Up Time 10 15/11 ms Min at full load, 115 VAC. Typical at 100W/ 130W
Drift ±0.02 % After 20 min warm up
Line Regulation ±0.5 % 90-264 VAC
Load Regulation ±0.5 % 0-100% load.
Transient Response 4%
Recovery within 1% in less than 500 µs
for a 50-75% and 75-50% load step
Over/Undershoot 7%Full load
Ripple & Noise 1 % pk-pk
<2% from no load to 10% load, <1% above 10% load.
20 MHz bandwidth and 10 µF electrolytic capacitator in
parallel with 0.1 µF ceramic capacitator.
Overvoltage Protection 110 140 % Vnom, recycle input to reset
Overload Protection 110 170 % I nom
Short Circuit Protection Trip & Restart
Temperature Coefficient 0.02 %/˚C
ECP130 Series
www.xppower.com 2
AC-DC Power Supplies
General
Characteristic Minimum Typical Maximum Units Notes & Conditions
Efficiency 95 % 230 VAC (see fig. 1 & 2)
Isolation: Input to Output
Input to Ground
Output to Ground
4000 VAC 2 MOPP
1500 VAC 1 MOPP
1500 VAC 1 MOPP
Switching Frequency 40 130 kHz PFC
50 135 kHz Main converter
Power Density 19.7/15.1 W/in3Forced/convection-cooled
Mean Time Between Failure 680 kHrs MIL-HDBK-217F, Notice 2 +25 °C GB
Weight 0.43(195) lb(g)
Characteristic Minimum Typical Maximum Units Notes & Conditions
Input Voltage - Operating 85115/230 264 VAC Derate output from 100% at 90 VAC to 85% at 85 VAC
Input Frequency 4750/60 63 Hz Agency approval, 47-63 Hz
Power Factor 0.8 230 VAC, 100% load EN61000-3-2 class A
Input Current - Full Load 1.3/0.65 A 115/230 VAC
Inrush Current 120 A 230 VAC cold start, 25 ºC
Earth Leakage Current 20/40 50 µA 115/230 VAC/50 Hz (Typ), 264 VAC/60 Hz (Max)
No load Input Power 0.5 W
Input Protection F3.15 A/250 V Internal fuse fitted in line and neutral.