MIL-C-20/Axial Leads HOW TO ORDER Military Type Designation: Established Reliability = CCR75, CCR76, CCR77, CCR78, CCR79 Non-Established Reliability = CC75, CC76, CC77, CC78, CC79 Part Number Example CCR76 CG 102 J R Style Temperature Characteristic Capacitance Code Capacitance Tolerance Military Failure Rate MIL Part No. Codes L 1.25 MIN. D L.D. Style: CC = Identifies temperature compensating, ceramic dielectric, fixed capacitors. R = Identifies Established Reliability parts. 76 = Numbers identify shape and dimension. Temperature Characteristic: SIZE SPECIFICATIONS Permissible capacitance change from capacitance at +25C in ppm/C Temp. Characteristic CX +125C -55C 2/ 1/ 1/ CK 250 ppm/C 120 ppm/C +246.25 -326.25 Dimensions: Millimeters (Inches) CJ +116.25 -166.25 CH CG 60 ppm/C 30 ppm/C +55.00 -91.25 +27.50 -53.75 Per MIL Spec Case Size MIL-C-20 Length (L) Diameter (D) Lead Diameter (L.D.) CCR75 CC75 4.07.25 (.160.010) 2.29.25 (.090.010) .48.05 (.019.002) CCR76 CC76 6.35.25 (.250.010) 2.29.25 (.090.010) .48.05 (.019.002) CCR77 CC77 9.91.25 (.390.010) 3.56.25 (.140.010) .63.05 (.025.002) CCR78 CC78 12.7.51 (.500.020) 6.35.38 (.250.015) .63.05 (.025.002) CCR79 CC79 17.53.51 (.690.020) 8.89.51 (.350.020) .63.05 (.025.002) 1/ Not practically measurable. Capacitance Code: First two digits are the significant figures of capacitance. Third digit indicates the additional number of zeros. For example, order 1,000 pF as 102. (For values below 10 pF, use "R" in place of decimal point, e.g., 1R8 - 1.8pF). Capacitance Tolerance: C = 0.25 pF, D = 0.5 pF, F = 1%, G = 2%, J = 5%, K = 10% Military Failure Rate: M = 1% per 1000 hours, P = 0.1% per 1000 hours, R = 0.01% per 1000 hours, S = 0.001% per 1000 hours. PACKAGING REQUIREMENTS Packaging: Bulk CCR75/CC75, CCR76/CC76, CCR77/CC77, CCR78/CC78, CCR79/CC79 Tape & Reel CCR75/CC75, CCR76/CC76 CCR77/CC77 CCR78/CC78 CCR79/CC79 100 pcs/bag 50 pcs/bag 59 5000 pcs/reel 3000 pcs/reel 950 pcs/reel 650 pcs/reel MIL-C-20/Axial Leads Military Part Number Identification CC75 thru CC79 and CCR75 thru CCR79 Military Type Designation Capacitance Capacitance (pF) Tolerance Military Type Designation WVDC Capacitance Capacitance (pF) Tolerance CC75-CCR75 CCR75CX1R0_ CCR75CX1R1_ CCR75CX1R2_ CCR75CX1R3_ CCR75CX1R5_ CCR75CX1R6_ CCR75CX1R8_ CCR75CX2R0_ CCR75CK2R2_ CCR75CK2R4_ CCR75CK2R7_ CCR75CK3R0_ CCR75CK3R3_ CCR75CK3R6_ CCR75CK3R9_ CCR75CJ4R3_ CCR75CJ4R7_ CCR75CJ5R1_ CCR75CJ5R6_ CCR75CJ6R2_ CCR75CJ6R8_ CCR75CJ7R5_ CCR75CH8R2_ CCR75CH9R1_ CCR75CH100_ CCR75CH110_ CCR75CH120_ CCR75CH130_ CCR75CH150_ CCR75CH160_ CCR75CH180_ CCR75CG200_ CCR75CG220_ CCR75CG240_ CCR75CG270_ CCR75CG300_ 1.0 1.1 1.2 1.3 1.5 1.6 1.8 2.0 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1 10 11 12 13 15 16 18 20 22 24 27 30 C C C C C C C C C C C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D G, J G, J G, J G, J G, J G, J G, J F, G, J F, G, J F, G, J F, G, J F, G, J WVDC CC75-CCR75 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 CCR75CG330_ CCR75CG360_ CCR75CG390_ CCR75CG430_ CCR75CG470_ CCR75CG510_ CCR75CG560_ CCR75CG620_ CCR75CG680_ CCR75CG750_ CCR75CG820_ CCR75CG910_ CCR75CG101_ CCR75CG111_ CCR75CG121_ CCR75CG131_ CCR75CG151 CCR75CG161_ CCR75CG181_ CCR75CG201_ CCR75CG221_ CCR75CG241_ CCR75CG271_ CCR75CG301_ CCR75CG331_ CCR75CG361_ CCR75CG391_ CCR75CG431_ CCR75CG471_ CCR75CG511_ CCR75CG561_ CCR75CG621_ CCR75CG681_ 33 36 39 43 47 51 56 62 68 75 82 91 100 110 120 130 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J 200 200 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 50 50 50 50 50 50 50 Add appropriate failure rate level (M, P, R or S) Add appropriate cap. tolerance letter Add appropriate failure rate level (M, P, R or S) Add appropriate cap. tolerance letter Note: For marking information, see page 63. 60 MIL-C-20/Axial Leads Military Part Number Identification CC75 thru CC79 and CCR75 thru CCR79 Military Type Designation Capacitance Capacitance (pF) Tolerance Military Type Designation WVDC Capacitance Capacitance (pF) Tolerance CC76, CCR76 CCR76CG820_ CCR76CG910_ CCR76CG101_ CCR76CG111_ CCR76CG121_ CCR76CG131_ CCR76CG271_ CCR76CG301_ CCR76CG331_ CCR76CG361_ CCR76CG391_ CCR76CG431_ CCR76CG471_ CCR76CG511_ CCR76CG561_ CCR76CG621_ CCR76CG681_ CCR76CG751_ CCR76CG821_ CCR76CG911_ CCR76CG102_ 82 91 100 110 120 130 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1,000 CCR77CG151_ CCR77CG161_ CCR77CG181_ CCR77CG201_ CCR77CG221_ CCR77CG241_ CCR77CG271_ CCR77CG301_ CCR77CG331_ CCR77CG361_ CCR77CG391_ CCR77CG431_ CCR77CG471_ CCR77CG511_ CCR77CG561_ CCR77CG621_ CCR77CG681_ CCR77CG751_ CCR77CG821_ CCR77CG911_ CCR77CG102_ CCR77CG112_ CCR77CG122_ CCR77CG132_ CCR77CG152_ CCR77CG162_ CCR77CG182_ CCR77CG202_ CCR77CG222_ CCR77CG242_ CCR77CG272_ 150 160 180 200 220 240 270 300 330 360 390 430 470 510 560 620 680 750 820 910 1,000 1,100 1,200 1,300 1,500 1,600 1,800 2,000 2,200 2,400 2,700 F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 50 50 50 50 CCR77CG302_ CCR77CG332_ CCR77CG362_ CCR77CG392_ CCR77CG432_ CCR77CG472_ CCR77CG512_ CCR77CG562_ 3,000 3,300 3,600 3,900 4,300 4,700 5,100 5,600 CCR78CG821_ CCR78CG102_ CCR78CG122_ CCR78CG152_ CCR78CG182_ CCR78CG222_ CCR78CG272_ CCR78CG332_ CCR78CG392_ CCR78CG472_ CCR78CG562_ CCR78CG682_ CCR78CG822_ CCR78CG103_ CCR78CG123_ CCR78CG153_ CCR78CG183_ CCR78CG223_ CCR78CG273_ 820 1,000 1,200 1,500 1,800 2,200 2,700 3,300 3,900 4,700 5,600 6,800 8,200 10,000 12,000 15,000 18,000 22,000 27,000 CCR79CG392_ CCR79CG472_ CCR79CG562_ CCR79CG682_ CCR79CG822_ CCR79CG103_ CCR79CG153_ CCR79CG183_ CCR79CG223_ CCR79CG273_ CCR79CG333_ CCR79CG393_ CCR79CG473_ CCR79CG563_ CCR79CG683_ CCR79CG823_ 3,900 4,700 5,600 6,800 8,200 10,000 15,000 18,000 22,000 27,000 33,000 39,000 47,000 56,000 68,000 82,000 F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J, K F, G, J, K 50 50 50 50 50 50 50 50 CC78, CCR78 CC77, CCR77 F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J F, G, J WVDC CC77, CCR77 (cont) 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 100 100 100 100 100 50 50 F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100 50 50 50 50 CC79, CCR79 F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K F, G, J, K 200 200 200 200 200 200 100 100 100 100 100 100 50 50 50 50 Add appropriate failure rate level (M, P, R or S) Add appropriate cap. tolerance letter Add appropriate failure rate level (M, P, R or S) Add appropriate cap. tolerance letter Note: Complete type designation will include the appropriate capacitance tolerance in the 11th digit. For CC styles, delete 3rd and 12th digits. Note: For marking information, see page 62. 61 MIL-C-20 MARKING Radials Axials CC05 & CC09 CC05 CH 100G 9910 A0 4222 FRONT BACK CC75, CC76 Date Code A=Lot Letter 0=1st Digit of AVX FSCM # 4222=Last four digits of AVX FSCM # CG 101 G99 10AAA CCR05 & CCR09 CCR0 5CH1 00GM 9910 AJ0 4222 FRONT BACK CCR75, CCR76 Date Code A=Lot Letter J="J" or "JAN" Brand 0=1st Digit of AVX FSCM # 4222=Last four digits of AVX FSCM # JCG 101 GM99 10AAA CC06 CC06 CG 102F 9910A 200V 04222 FRONT BACK Characteristic Capacitance Value Cap. Tolerance & 2 digit Year Code 2 digit Week, 2 digit Lot Code, A for AVX "J" Brand (J) and Characteristic (CG) Capacitance Value Cap. Tolerance (G) FR Level (M), & 2 digit Year Code 2 digit Week, A for AVX CC77 Date Code & Lot Letter 200V=Rated Voltage 04222=AVX FSCM # CC77C G151F 04222 9910AA Type Designation FSCM 4 digit Date Code, 2 digit Lot Code CCR06 CCR06 CG102 FM 9910A J200V 04222 FRONT BACK Date Code & Lot Letter J="J" or "JAN" Brand 200V=Rated Voltage 04222=AVX FSCM # CCR77 CCR77C G151FM JO4222 9910AA Type Designation "J" Brand and FSCM 4 digit Date Code, 2 digit Lot Code CC07 CG 103 G9 AAVX Characteristic Capacitance Value Cap. Tolerance & Year Code (9 for 1999) Lot Code & Trademark CC78, CC79 CCR07 JCG 103 GM9 AAVX "J" Brand (J) and Characteristic (CG) Capacitance Value Cap. Tolerance (G) FR Level (M), & Year Code (9 for 1999) Lot Code (A); and Trademark (AVX) Trademark or Manufacturer's Name Source Code (FSCM) Voltage, Date Code and Lot Symbol CCR08 CCR08CG 392KM JAN AVX 96095 200V 9910A "JAN" Brand & Trademark or Manufacturer's Name Source Code (FSCM) Voltage, Date Code and Lot Symbol 62 Type Designation Trademark or Manufacturer's Name Source Code (FSCM) Voltage 4 digit Date Code CCR78, CCR79 CCR78 CG 821KM JAN A 04222 200V 9910AA CC08 CC08CG 392K AVX 96095 200V 9910A CC78CG 821K AVX 04222 200V 9910AA Type Designation TC Capacitance Tolerance, Failure Rate "JAN" Brand, A for AVX FSCM Voltage 4 digit Date Code, 2 digit Lot Code