10) Apply an input signal in the 0 to VREF (4.096V)
range between AIN2 and GND. Observe the read-
out on the screen.
11) To view a graph of the measurements, pull down
the View menu and click Graph.
Detailed Description of Software
Main Window
The evaluation software’s main window shows a block
diagram of the MAX1253/MAX1254, with many click-
able features. Each feature can be operated from the
block diagram tab sheet or from the other tab sheets
(see Figure 1.)
Press function key F1 at any time to return to the block
diagram tab sheet. Press function key F2 to pop up a
window containing the most recent data readings. The
software reads the data registers every 300ms, unless
disabled by unchecking Poll All Data Registers under
the Device menu (see Figure 3.)
At startup, the evaluation software reads the device con-
figuration. To initialize the MAX1254 for the evaluation kit
board, press function key F10. This enables the internal
reference, with AIN0 and AIN1 for differential temperature
measurement, enables AIN2 through AIN5 for single-
ended voltage inputs, and disables AIN6 and AIN7 (see
Figure 2.)
The Data Regs tab sheet provides read and write
access to all channel data registers. Individual measure-
ments must be triggered unless scanning mode has
been enabled. The data write commands are useful for
preloading nominal initial values into the channel averag-
ing filters. The Reference Voltage value only affects the
displayed voltages, not the raw measurement codes
(see Figure 4.)
The Global Registers tab sheet covers the global con-
figuration registers in three groups: channel enable,
input configuration, and setup. The Input Configuration
tab sheet determines how each pair of inputs is connect-
ed. The Setup Register tab sheet configures internal or
external reference voltage, interrupt output level, and
scanning. All three of these subgroups require clicking
the Apply button to write the new configuration into the
device (see Figures 5, 6, 7.)
The INT pin status is normally shown in the status bar,
unless disabled by unchecking Poll INT Pin under the
Device menu.
The Alarm Register tab sheet reads and clears the alarm
register. Alarm fault status is normally displayed in the
status bar, unless disabled by unchecking Poll Alarm
Status under the Device menu (see Figure 8.)
The Channel Configuration tab sheet configures each
channel’s fault detection and averaging. After changing
any channel’s settings, click the Apply button to write
the new configuration into the device (see Figure 9.)
Graph Window
To view recently measured data, drop down the View
menu and choose Graph. Data may be viewed as a time
sequence plot, a histogram plot, or as a table of raw
numbers. See Table 5 for available graph commands.
Graph
The evaluation software has two options for graphing
data. A graph of recent data can be displayed by select-
ing the View menu and then Graph. To control the size
and timing of the data runs, activate the sampling tool by
clicking the main window’s Collect Samples button.
Sampled data can be saved into a file in comma-delim-
ited or tab-delimited format. Line numbers and a
descriptive header line are optional.
Graph channel 0 plots the internal temperature of the
MAX1254. Channel 1 is VDD. Channels 2 through 9 are
MAX1254 AIN0 through AIN7.
Evaluating the MAX1253
With power off, replace U1 with a MAX1253BEUA.
Follow the Quick Start instructions, except in step 1
select VDD = 3V by setting JU1 to 2-3 position. Tell the
software the reference voltage is 2.5V.
Diagnostics Window
The diagnostics window is used for factory testing
prior to shipping the evaluation kit. It is not intended for
customer use.