279
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly
Assembly Instructions-C7R Amphenol®
BNC
2-PIECE CRIMP PLUGS
Step 1 Strip cable jacket, braid, and dielectric to dimensions
in table above. All cuts are to be sharp and square.
Important: Do not nick braid, dielectric, and center
conductor. Slide outer ferrule onto cable as shown.
Step 2 Flare slightly end of cable braid as shown to facilitate
insertion of inner ferrule of connector. Important: Do not
comb out braid.
Step 3 Install cable assembly into body assembly so that inner
ferrule portion slides under braid. Slide outer ferrule over
braid and up against connector body. Crimp outer ferrule
using Die Set Cavity specified in table above.
Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm)
Number Type RG-/U
Cavity for Die Set for CTL Series
Outer Ferrule Tool 227-944* Tool Number abcd
31-5556-RFX BNC Plug 59, 62 .324(8.2) 227-1221-32 CTL-2 .437(11.1) .312(7.9) .248(6.3) .125(3.2)
31-5557-RFX BNC Plug 58 .324(8.2) 227-1221-32 CTL-2 .437(11.1) .312(7.9) .248(6.3) .125(3.2)
31-5560-RFX BNC Plug Plenum 59, 62 .324(8.2) 227-1221-32 CTL-2 .437(11.1) .312(7.9) .248(6.3) .125(3.2)
outer ferrule plug body assembly
Step 1
Step 2
Step 3
a
bc
299
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly
CLAMP CONNECTORS
Step 1
Step 2
Step 3
Step 4
Step 5
For angle plugs only: (except 31-204) Solder center
conductor to preassembled contact. Assemble cap and
lightly punch center of cap for retention in body, or solder in
place.
Step 1 Place nut, washer (when supplied) and gasket over cable
and strip jacket to dimension ashown in table above.
Step 2 Comb out braid and fold out. Trim insulation off center
conductor to dimension cshown in table above. [For RG-62,
71 and 210/U cable, trim an additional .032"(0.8mm) of
insulation off center conductor and add bushing.] Tin
center conductor.
Step 3 Pull braid wires forward and taper toward center conductor.
Place clamp over braid and push back against cable
jacket.
Step 4 Fold back braid wires as shown, trim to proper length
[approximately .125" (3.2mm) long] and form over clamp
as shown. Braid wire should not extend beyond step of
braid clamp. Solder contact to center conductor, sliding
bushing first (when supplied) over center conductor.
Step 5 Insert cable and parts into connector body. Make sure
sharp edge of clamp seats properly in gasket. Tighten nut
to approximately 15 inch pounds.
nut washer* gasket clamp bushing‡ female contact jack body male contact plug body
* Not supplied on all items ‡ For use on RG-62, 71, 122, 178, 180, 196, 210
Amphenol
Connector Cable Stripping Dims,
Number Type RG-/U Inches (Millimeters)
ac
6775 BNC Plug 8, 9, 11, 213, 214 .490(12.4) .200(5.1)
6775-75 75BNC Plug 11 .490(12.4) .200(5.1)
8525 BNC Angle Plug 58, 141, 142, 400 .343(8.7) .187(4.7)
8575 BNC Angle Plug 59, 62, 140, 210 .297(7.5) .094(2.4)
9350 BNC Plug 6 .405(10.3) .094(2.4)
15875 BNC Plug 178, 196 .156(3.96) .078(1.98)
16300 BNC Plug 180 .250(6.4) .094(2.4)
33275 BNC Angle Plug 174, 179, 187, 188, 316 .540(13.7) .156(3.96)
69475 BNC Plug 174, 179, 187, 188, 316 .281(7.1) .172(4.4)
84975 BNC Plug 122 .281(7.1) .172(4.4)
86350 BNC Bulkh. Jack 174, 179, 187, 188, 316 .265(6.73) .156(3.96)
86425 BNC Panel Jack 174, 179, 187, 188, 316 .313(7.95) .203(5.15)
86850 BNC Bulkh. Jack 178, 196 .266(6.75) .109(2.76)
31-2 BNC Plug 58, 141, 142, 400 .312(7.9) .094(2.4)
31-2-RFX BNC Plug 58, 141, 142A .315(8.0) .118(3.0)
31-15 BNC Jack 59, 62, 71, 140, 210 .297(7.54) .109(2.75)
31-202 BNC Plug 55, 58, 141, 142, 223, 400 .274(6.95) .094(2.4)
31-204 BNC Angle Plug 55, 58, 141, 142, 223, 400 .297(7.54) .109(2.8)
31-206 BNC Bulkhead Jack 58, 141, 142, 400 .297(7.5) .109(2.8)
31-207 BNC Bulkhead Jack 59, 62, 71, 140, 210 .297(7.54) .209(2.75)
31-212 BNC Plug 59, 62, 71, 140, 210, 302 .250(6.4) .094(2.4)
31-212-1005 BNC Plug 59 (20GA CC) .250(6.4) .094(2.4)
31-850 BNC Angle Plug 59, 62, 71, 140, 210 .375(9.52) .125(3.17)
31-3202 BNC Plug 55, 58, 141, 142, 223, 400 .250(6.4) .094(2.4)
31-3301 BNC Plug 58, 141, 142, 223 .250(6.4) .094(2.4)
31-3302 BNC Plug 59, 62, 71, 140, 210 .250(6.4) .094(2.4)
a
c
Assembly Instructions-C25 Amphenol®
BNC
300
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
3-PIECE CRIMP PLUGS
Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm)
Number Type RG-/U
Cavity for Cavity for Die Set for CTL Series
Contact Outer Ferrule Tool 227-944* Tool Number ab c
36650-1003 BNC Plug Belden 82907, 88240 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
89907, Plenum 58
36650-3RFX BNC Plug Plenum 58 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .630(16.0) .319(8.1) .157(4.0)
36875 BNC Plug 55, 142, 223, 400 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
68175-1003 BNC Plug Belden 9259 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
68175-1005 BNC Plug 59 (20AG CC) .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
68175-1011 BNC Plug Belden 1560A, 82259, .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
89259, Plenum 59, 62
68175-11RFX BNC Plug Plenum 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .157(4.0)
68175-5RFX BNC Plug 59 (20GA CC) .068(1.7) .255(6.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .157(4.0)
31-242 BNC Plug 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-242-RFX BNC Plug 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .590(15.0) .323(8.2) .118(3.0)
31-315 BNC Plug 174, 188, 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-315-RFX BNC Plug 174, 188, 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-315-1005 BNC Plug Dbl. Br. 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-320 BNC Plug 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-320-RFX BNC Plug 58A, 141, 142A .068(1.7) .213(5.4) 227-1221-11 CTL-1 .630(16.0) .303(7.7) .156(4.0)
31-320-1006 BNC Plug Belden 9907, 89907 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-321 BNC Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-321-RFX BNC Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .156(4.0)
31-321-1000 BNC Plug Belden 8281, 88281 .068(1.7) .324(8.2) 227-1221-32 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-321-10RFX BNC Plug Belden 8281 .068(1.7) .324(8.2) 227-1221-32 CTL-2 .630(16.0) .303(7.7) .156(4.0)
31-325 BNC Plug Belden 8218 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-326 BNC Plug 55, 142, 223 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-326-RFX BNC Plug 55, 142, 223, 400 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-4320 BNC Plug 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-4321 BNC Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-4411 BNC Plug Belden 8213 .100(2.5) .429(10.9) 227-1221-25 CTL-3 .650(16.5) .250(6.4) .156(4.0)
31-4427 BNC Plug 142, 400 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-5558-RFX BNC Plug 6 Type (.314OD) .068(1.7) .324(8.2) 227-1221-32 CTL-2 .630(16.0) .303(7.7) .156(4.0)
31-5800 BNC Plug 58, 141, PL-58 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-5900 BNC Plug 59, 62, 59 (20GA CC), .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
Plenum -59, 62
* for pneumatic crimp tool 227-60, use die sets indicated in this column.
outer ferrule bushing male contact plug body assembly
used with RG-62, 71, 210 cable only
Assembly Instructions-C26 Amphenol®
BNC
■ ▲
For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm)
as shown. Before attaching center contact, slide metal spacer/TFE sleeve
(not shown) over cable dielectric and under braid. The center contact
should butt against the dielectric and TFE sleeve.
Step 1 Step 2 Step 3
contact must butt against cable dielectric
abc
Step 1 Strip cable jacket, braid, and dielec-
tric to dimensions in table above. [for RG-
62,71,210/U cable, trim an additional
.039"(1.0mm) of insulation off center conduc-
tor and add bushing] All cuts are to be sharp
and square.
Important: Do not nick braid, dielectric, and
center conductor. Slide outer ferrule onto
cable as shown.
Step 2 Flare slightly end of cable braid as
shown to facilitate insertion of inner ferrule.
Important: Do not comb out braid .
Place contact on cable center conductor so
that it butts against cable dielectric. Crimp
contact in place using Die Set Cavity indicat-
ed in table above. When using RG-62, 71,
210 cable, install bushing over center con-
ductor before installing contact.
Step 3 Install cable assembly into body
assembly so that inner ferrule portion slides
under braid. Push cable assembly forward
until contact snaps into place in insulator.
Slide outer ferrule over braid and up against
connector body. Crimp outer ferrule using
Die Set Cavity specified in table above.
cable dielectric must butt insulator
outer ferrule should butt here
crimp here
3-PIECE CRIMP ANGLE PLUGS & BULKHEAD JACKS
outer ferrule bushing male contact plug body assembly
used with RG-62, 71, 210 cable only
Step 1
■ ▲
For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm)
as shown. Before attaching center contact, slide metal spacer/TFE sleeve
(not shown) over cable dielectric and under braid. The center contact
should butt against the dielectric and TFE sleeve.
Step 2 contact must butt against cable dielectric
Step 3
abc
cable dielectric must butt insulator
outer ferrule should butt here
crimp here
301
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly
Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm)
Number Type RG-/U
Cavity for Cavity for Die Set for CTL Series
Contact Outer Ferrule Tool 227-944* Tool Number ab c
36800 BNC Jack 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
36800-RFX BNC Jack 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .630(16.0) .303(7.7) .156(4.0)
68150 BNC Jack 59, 62, 140 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
95700 BNC Bulkh. Jack 55, 142, 223 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-245 BNC Bulkh. Jack 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-316 BNC Angle Plug 174, 188, 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .578(14.6) .328(8.3) .125(3.1)
31-317 BNC Jack 174, 188, 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-318 BNC Bulkh. Jack 174, 188, 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-318-RFX BNC Bulkh. Jack 174, 188, 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .630(16.0) .362(9.2) .156(4.0)
31-318-1001 BNC Bulkh. Jack Dbl. Br. 316 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-245-RFX BNC Bulkh. Jack 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .630(16.0) .362(9.2) .156(4.0)
31-334 BNC Angle Plug 55, 142, 223, 400 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .578(14.6) .328(8.3) .125(3.1)
31-335 BNC Angle Plug 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .578(14.7) .328(8.3) .125(3.2)
31-335-RFX BNC Angle Plug 58, 144 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .677(17.2) .350(8.9) 156(4.0)
31-336 BNC Angle Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .578(14.7) .328(8.3) .125(3.2)
31-336-RFX BNC Angle Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .677(17.2) .350(8.9) .156(4.0)
31-342 BNC Bulkh. Jack 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-342-RFX BNC Bulkh. Jack 58, 141, 142, 223 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .689(17.5) .362(9.2) .157(4.0)
31-343-1002 BNC Bulkh. Jack Pl. 59 (20 AWG) .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-343-RFX BNC Bulkh. Jack 59, 62, 140, 210 .068(1.7) .255(6.5) 227-1221-11 CTL-1 .689(17.5) .362(9.2) .157(4.0)
31-4327 BNC Jack 58, 141 .068(1.7) .213(5.4) 227-1221-11 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-5911-RFX BNC Angle Plug 58,141 Solder .213 227-1221-11 CTL-1,3,5 .709(18.0) .382(9.7) .161(4.1)
31-5914-RFX BNC Angle Plug 59 Solder .255 227-1221-13 CTL-1,5,6,8 .709(18.0) .382(9.7) .161(4.1)
31-5991-RFX BNC Angle Plug 316 Solder .128 227-1221-3 CTL-9,13 .618(15.7) .350(8.9) .157(4.0)
31-316-RFX BNC Angle Plug 316 Solder .128 227-1221-3 CTL-9,13 .618(15.7) .350(8.9) .157(4.0)
31-70239 BNC Angle Plug 734A .042 .255 CTL-14 .630 (16.0) .303 (7.7) .157 (4.0)
31-70240 BNC Angle Plug 735A .042 .187 CTL-15 .630 (16.0) .303 (7.7) .157 (4.0)
31-70234 BNC Plug Beld 1694 .042 .319 CTL-14 .630 (16.0) .303 (7.7) .157 (4.0)
31-70235 BNC Plug Beld 8281 .042 .324 CTL-14 .630 (16.0) .303 (7.7) .157 (4.0)
31-70236 BNC Plug Beld 8218 .042 .178 CTL-15 .630 (16.0) .303 (7.7) .157 (4.0)
31-70237 BNC Plug 734A .042 .255 CTL-14 .630 (16.0) .303 (7.7) .157 (4.0)
31-70238 BNC Plug 735A .042 .187 CTL-15 .630 (16.0) .303 (7.7) .157 (4.0)
31-315-RFX BNC Plug 174,188,316 .068 .178 227-1221-9 CTL-2 .593 (15.1) .250 (6.4) .156 (4.0)
31-317-RFX BNC Jack 174,188,316 .068 .178 227-1221-9 CTL-2 .634 (16.1) .303 (7.7) .156 (4.0)
31-335-RFX BNC Angle Plug 58,141,142 .068 .213 227-1221-11 CTL-1,5 .677 (17.2) .350 (8.9) .157 (4.0)
31-5998-RFX BNC Plug
B8214,B9913,B9914
.118 .429 227-1221-61 CTL-11 .630 (16) .303 (7.7) .157 (4.0)
31-5999-RFX BNC Plug 8x,LMR240 .068 .255 227-1221-13 CTL-1,5 .630 (16) .303 (7.7) .157 (4.0)
31-6004-RFX BNC Angle Plug B9913,B9914 Solder .429 227-1221-25 CTL-4 .728 (18.5) .401 (10.2) .244 (6.2)
31-6005-RFX BNC Angle Plug 8x,LMR240 Solder .255 227-1221-13 CTL-1,5 .728 (18.5) .401 (10.2) .244 (6.2)
31-6006 BNC Plug 8x,LMR240 .068 .255 227-1221-13 CTL-1,5 .593 (15.1) .250 (6.4) .156 (4.0)
Step 1 Strip cable jacket, braid, and dielectric to dimensions in table above. [for
RG-62,71,210/U cable, trim an additional .039"(1.0mm) of insulation off
center conductor and add bushing] All cuts are to be sharp and square.
Important: Do not nick braid, dielectric, and center conductor. Slide
outer ferrule onto cable as shown.
Step 2 Flare slightly end of cable braid as shown to facilitate insertion of inner fer-
rule. Important: Do not comb out braid .Place contact on cable center
conductor so that it butts against cable dielectric. Crimp contact in place
using Die Set Cavity indicated in table above. When using RG-62, 71,
210 cable, install bushing onto center conductor before installing contact.
Step 3 Install cable assembly into body assembly so that inner ferrule portion
slides under braid. Push cable assembly forward until contact snaps into
place in insulator. Slide outer ferrule over braid and up against connector
body. Crimp outer ferrule using Die Set Cavity specified in table
above.
* for pneumatic crimp tool 227-60, use die sets indicated in this column
Assembly Instructions-C26a Amphenol®
BNC
302
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
ORIGINAL CRIMP PLUGS
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 1 Install boot and slide outer ferrule onto cable as shown prior
to stripping cable.
Step 2 Strip cable jacket, braid and dielectric to dimensions shown.
See attached table for dimensions. All cuts are to be sharp
and square. Important: DO NOT nick braid, dielectric, and
center conductor when cutting. Tin center conductor using
soft solder per QQ-S-571 comp Sn 60. Avoid excessive heat
while tinning to prevent swelling of cable dielectric.
Step 3 Slightly flare out end of cable braid as so as to facilitate
insertion onto ferrule clamp nut assembly. Important:
DO NOT comb out braid.
Step 4 Install ferrule clamp nut assembly onto cable so that ferrule
portion slides under braid and insulator butts flush against
cable dielectric. Slide outer ferrule over braid and up
against nut. Make sure no slack exists in braid. Crimp outer
ferrule with tool specified in table above, keeping cable
dielectric bottomed against insulator.
Step 5 Soft solder center conductor to contact using rosin core per
QQ-S-571 comp Sn 60. DO NOT get any solder on outside
surfaces of contact.
Step 6 Screw connector body onto prepared cable termination .
Wrench tighten by holding the cable nut assembly
STATIONARY while ROTATING the connector body.
Step 7 Push body forward and into position as shown to complete
assembly.
Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm)
Number Type RG-/U
Cavity for Cavity for Die Set for
Contact Outer Ferrule Tool 227-944* ab c
31-351 BNC Plug 58, 141 .213(5.4) 227-1221-11 .922(23.4) .516(13.1) .250(6.3)
31-359 BNC Plug 59, 62, 140 .255(6.5) 227-1221-13 .922(23.4) .516(13.1) .250(6.3)
31-371 BNC Plug 174, 179, 187, 188, 316 .128(3.2) 227-1221-3 .797(20.2) .516(13.1) .250(6.3)
boot ferrule ferrule clamp plug body assembly
nut assembly
FERRULE/ GO SS
OUTER FERRULE CLAMP NUT ASSY
BOOT
* for pneumatic crimp tool 227-60, use die sets indicated in this column
STEP 1
boot outer ferrule
STEP 2
STEP 4
STEP 5
P 3
STEP 6
STEP 7
outer ferrule must
clamp nut assy
as shown
cable dielectric must
butt insulator as shown
note: center conductor must
be visible thru contact solder
hole prior to soldering
lip of boot must be firmly posi-
tioned in body groove
a
b
c
Assembly Instructions-C26b Amphenol®
BNC
303
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly
Assembly Instructions-C28 Amphenol®
BNC
Step 1
Step 2
Step 3
Step 4
Step 1 Strip cable as shown. Take care not to nick center
conductor or outer braid.
Step 2 Twist outer braid in a clockwise direction so that at least
1/32" of cable dielectric is bared, and braid is left flat. (Stray
or loose braid can cause shorts.)
Step 3 Gently insert center conductor into back end of connector,
"feeling" it into the guide hole. (If center conductor is NOT
properly in place, about 1/8" of center conductor will show at
the back end. Reinsert until cable dielectric reaches position
shown in illustration.)
Step 4 Push the cable firmly home (as far as possible). Then screw
the connector onto the cable in a clockwise direction until it
stops. Assembly is complete.
BNC SURETWIST® plug
Amphenol Connector Cable
Number Type RG-/U
31-5136 BNC Plug 59
31-5136-RFX BNC Plug 59
31-5137 BNC Plug 58
31-5137-RFX BNC Plug 58
.563
(14.3)
.813
(20.7)
.250
(6.4)
min. of cable
dielectric
.031
(0.8)
Back end of connector and
cable dielectric flush,
center conductor in place
SURETWIST®PLUG
304
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Step 1A
Step 1B
Step 2
Step 3
Step 4
Step 1A For all connectors except 31-4541-RFX (see step 1B).
Slide clamp nut over cable. Strip cable to dimension
shown. Cut braid and dielectric square. Do not nick
center conductor.
Step 1B For 31-4541-RFX.. Same as step 1A except use Step 1B
strip dimensions, and then slit jacket back .125"(3.2 mm) in
four places 90° apart as shown in illustration.
Step 2 Slide contact assembly under braid and jacket until braid
butts as shown. Use caution that braid slides over contact
assembly and not inside of it. Be sure center conductor
is visible through side hole of contact. Solder contact to
center conductor. Contact may be crimped on applicable
connectors using Amphenol CTL-1 crimp tool; or by using
die set 227-1221-13 cavity B in tool frame 227-944 or
equivalent tool
.
Step 3 Insert into connector body.
Step 4 T ighten clamp nut to a torque of 35 lbf-in.
clamp nut contact assembly plug body
Amphenol Connector Cable Center Contact Affixment
Number Type RG-/U Hex Size
Die Set for CTL Series
Tool 227-944* Tool Number
31-4541 BNC Plug 59, 59A, 62, 62A
31-4541-RFX
31-4542 BNC Plug Belden 9268 .068(1.7) 227-1221-13 CTL-1
Montrose CBL-5098 Cavity B
31-30220-1 BNC Plug 58
31-30220-8 BNC Plug 223
* for pneumatic crimp tool 227-60, use die sets indicated in this column
.250
(6.4)
.338(8.6)
.275(7.0)
.216
(5.5)
Assembly Instructions-C29 Amphenol®
BNC
QUICKTRIM®PLUG
305
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly
PLUGS FCP TERMINATION
Step 1
Step 2
Step 3
Step 4
Step 1 Slide ferrule over cable end, slotted end first. Strip cable to
dimensions shown. Do not nick center conductor. Flare
braid slightly as shown.
Step 2 Tin exposed center conductor. Solder center contact on
center conductor. Use minimum heat to avoid damaging
cable insulation. Remove any excess solder and flux from
contact surface. Contact may be crimped using
227-1221-11 die set (cavity B) .068 hex in tool handle
227-944 or equivalent tool.
Step 3 Slide body over contact and cable insulation with barb going
UNDER flared braid. Push body until shoulder is against
cable jacket. Braid will flare out against body shoulder.
Step 4 Grasp cable with hand and push ferrule over barb until braid
is captured between ferrule and body flange. Assembly is
complete.
Amphenol Connector Cable
Number Type RG-/U
31-4700 BNC Plug 58, 141
31-4702 BNC Plug 59
outer ferrule center plug body assembly
contact
.250(6.4)
.156(4.0)
Assembly Instructions-C30 Amphenol®
BNC
306
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
CRIMP TERMINATION FOR TYPE 1 – 75CONNECTORS
Step 1
■ ▲
For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm)
as shown. Before attaching center contact, slide TFE sleeve (not shown)
over cable dielectric and under braid. The center contact should butt
against the dielectric and TFE sleeve.
Step 2
Step 3
Step 1 Slide outer ferrule over cables shown. Flare slightly end of
cable braid as shown to facilitate insertion of inner ferrule.
IMPORTANT: Do not comb out braid.
Step 2 Place contact onto center conductor so it butts against cable
dielectric. Crimp contact in place.
Step 3 Install cable assembly into body assembly so inner ferrule
slides over sleeve and under braid. Push cable assembly
forward until contact seats in insulator. Slide outer ferrule
over braid and up against connector body. Crimp outer
ferrule.
use die set 227-1448 with tool frame 227-944
outer ferrule contact body assembly
Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm)
Number Type RG-/U
Cavity for Cavity for CTL Series
Contact Outer Ferrule Tool No. abc
31-70000 75BNC Plug 6, Belden 9248, Plenum 6 .052(1.3) sq. .324(8.2) CTL-8 .577(14.7) .234(5.9) .140(3.6)
31-70000-1000 75BNC Plug 6, Belden 9248 .052(1.3) sq. .324(8.2) CTL-8 .577(14.7) .234(5.9) .140(3.6)
31-70008 75BNC Plug 59 .052(1.3) sq. .255(6.5) CTL-6 or 8 .577(14.7) .234(5.9) .140(3.6)
31-70008-1000 75BNC Plug 59 (20GA CC) .052(1.3) sq. .255(6.5) CTL-6 or 8 .577(14.7) .234(5.9) .140(3.6)
31-70008-3000 75BNC Plug 59 (.032 CC) .052(1.3) sq. .255(6.5) CTL-6 or 8 .577(14.7) .234(5.9) .140(3.6)
31-70009 75BNC Jack 59 .052(1.3) sq. .255(6.5) CTL-6 or 8 .557(14.1) .214(5.4) .156(4.0)
31-70013 75BNC Plug 179, 187 .052(1.3) sq. .178(4.5) CTL-6 .577(14.7) .234(5.9) .140(3.6)
31-70013-1000 75BNC Plug Dbl. Br. 179, ATT19224-L2 .052(1.3) sq. .178(4.5) CTL-6 .594(15.1) .250(6.4) .156(4.0)
31-70015-1000 75BNC Angle Plug Dbl. Br. 179,ATT19224-L2 .052(1.3) sq. .178(4.5) CTL-6 .649(16.5) .435(11.0) .125(3.2)
31-70016 75BNC Jack 179, 187 .052(1.3) sq. .178(4.5) CTL-6 .886(22.5) .451(11.4) .140(3.6)
31-70016-1000 75BNC Bulkh. Jack Dbl. Br. 179, ATT19224-L2 .052(1.3) sq. .178(4.5) CTL-6 .886(22.5) .451(11.4) .140(3.6)
31-70022 75BNC Plug ATT 728B, Belden 9231 .068(1.7)hex .324(8.2) CTL-8 .579(15.1) .125(3.2) .125(3.2)
31-70082 75BNC Angle Plug ATT 735A Solder Only .160(4.1) .635(16.1) .385(9.8) .200(5.1)
31-70222 75BNC Plug Belden 8281, 9231 .052(1.3) sq. .324(8.2) CTL- 8 .577(14.7) .234(5.9) .140(3.6)
a b
c
crimp contact
in this area
Assembly Instructions-C31 Amphenol®
BNC
307
Amphenol Corporation Tel: 800-627-7100 www.amphenolrf.com
Assembly
CRIMP TERMINATION FOR TYPE 2 – 75CONNECTORS
Step 1 Strip cable jacket, braid, and dielectric to dimensions
in table above. [for RG-62,71,210/U cable, trim an
additional .039"(1.0mm) of insulation off center conductor
and add bushing] All cuts are to be sharp and square.
Important: Do not nick braid, dielectric, and center
conductor. Slide outer ferrule onto cable as shown.
Step 2 Flare slightly end of cable braid as shown to facilitate
insertion of inner ferrule. Important: Do not comb out braid.
Place contact on cable center conductor so that it butts
against cable dielectric. Crimp contact in place using
Die Set Cavity indicated in table above. When using RG-62,
71, 210, install bushing over center conductor before
installing contact.
Step 3 Install cable assembly into body assembly so that inner
ferrule portion slides under braid. Push cable assembly
forward until contact snaps into place in insulator. Slide
outer ferrule over braid and up against connector body.
Crimp outer ferrule using Die Set Cavity specified in table
above.
* for pneumatic crimp tool 227-60, use die sets indicated in this column
outer ferrule bushingmale contact plug body assembly female contact jack body assembly
for use on RG-62, 71, 210 cable only
Step 1
■ ▲
For RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm)
as
shown. Before attaching center contact TFE sleeve (not shown) over cable
dielectric and under braid. For 31-71016, before attaching center contact.
Slide metal spacer/TFE sleeve (not shown) over cable dielectric and under
braid. The center contact should butt against the dielectric
and TFE sleeve.
Step 2
Step 3
abc
contact must butt against cable dielectric
Amphenol Connector Cable Hex Crimp Data Stripping Dimensions, inches (mm)
Number Type RG-/U
Cavity for Cavity for Die Set for CTL Series
Contact Outer Ferrule Tool 227-944* Tool No. abc
31-71000-RFX 75BNC Plug 6 .068(1.7) .324(8.2) 227-1221-32 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71008 75BNC Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-71008-RFX 75BNC Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .156(4.0)
31-71008-1RFX 75BNC Plug 59 (20GA CC) .068(1.7) .255(6.5) 227-1221-13 CTL-1 .630(16.0) .303(7.7) .156(4.0)
31-71008-1000 75BNC Plug 59, 62 (20GA CC) .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-71008-2000 75BNC Plug
Plenum
-59, B89269 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-71010 75BNC Angle Plug 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .578(14.7) .328(8.3) .125(3.2)
31-71010-RFX 75BNC Plug 59 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .677(17.2) .350(9.0) .156(4.0)
75BNC Plug 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .677(17.2) .350(9.0) .197(5.0)
31-71011 75BNC Bulkh. Jack 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-71011-RFX 75BNC Bulkh. Jack 59, 62 .068(1.7) .255(6.5) 227-1221-13 CTL-1 .689(17.5) .362(9.2) .157(4.0)
31-71013 75BNC Plug 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .539(15.1) .250(6.4) .156(4.0)
31-71013-RFX 75BNC Plug 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .590(15.0) .323(8.2) .118(3.0)
31-71013-1000 75BNC Plug Dbl. Br. RG-179 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71014-RFX 75BNC Jack 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .571(14.5) .303(7.7) .157(4.0)
31-71016 75BNC Bulkh. Jack 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71016-RFX 75BNC Bulkh. Jack 179, 187 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .630(16.0) .362(9.2) .157(4.0)
31-71032 75BNC Plug B8281, 88281 .068(1.7) .324(8.2) 227-1221-32 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71033 75BNC Plug B8218 .068(1.7) .178(4.5) 227-1221-9 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71034 75BNC Plug Belden 89292 .100(2.5) .429(10.9) 227-1221-25 CTL-3 .593(16.7) .250(6.4) .156(4.0)
31-71035 75BNC Plug PL-59 (20GA CC) .068(1.7) .255(6.5) 227-1221-13 CTL-1 .593(15.1) .250(6.4) .156(4.0)
31-71064 75BNC Plug Belden 9248, Pl-6 .068(1.7) .324(8.2) 227-1221-32 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71065 75BNC Plug Belden 9290 .068(1.7) .324(8.2) 227-1221-32 CTL-2 .593(15.1) .250(6.4) .156(4.0)
31-71066 75BNC Plug Quad Shield 59 .068(1.7) .263(6.7) 227-1221-15 .593(15.1) .250(6.4) .156(4.0)
outer ferrule should butt here
cable dielectric must butt insulator
Assembly Instructions-C32 Amphenol®
BNC