MC34268
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol Value Unit
Power Supply Input Voltage Vin 15 V
Power Dissipation and Thermal Characteristics
DT Suffix, Plastic Package, Case 369A
TA = 25°C, Derate Above TA = 25°C
Thermal Resistance, Junction−to−Case
Thermal Resistance, Junction−to−Air
D Suffix, Plastic Package, Case 751
TA = 25°C, Derate Above TA = 25°C
Thermal Resistance, Junction−to−Case
Thermal Resistance, Junction−to−Air
ST Suffix, Plastic Package, Case 318E
TA = 25°C, Derate Above TA = 25°C
Thermal Resistance, Junction−to−Case
Thermal Resistance, Junction−to−Air
PD
RqJC
RqJA
PD
RqJC
RqJA
PD
RqJC
RqJA
Internally Limited
5.0
87
Internally Limited
22
140
Internally Limited
15
245
W
°C/W
°C/W
W
°C/W
°C/W
W
°C/W
°C/W
Operating Ambient Temperature Range TA0 to +125 °C
Maximum Die Junction Temperature TJ+150 °C
Storage Temperature Tstg −55 to +150 °C
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit values
(not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied, damage
may occur and reliability may be affected.
ELECTRICAL CHARACTERISTICS
(Vin = 4.25 V, CO = 10 mF, for typical values TA = 25°C, for min/max values TA = 0°C to +125°C, unless otherwise noted.)
Characteristic Symbol Min Typ Max Unit
Output Voltage (TA = 25°C, IO = 0 mA)
Output Voltage, over Line, Load, and Temperature (Vin = 3.9 V to 15 V,
IO = 0 mA to 490 mA)
VO2.81
2.76
2.85
2.85
2.89
2.93
V
Line Regulation (Vin = 4.25 V to 15 V, IO = 0 mA, TA = 25°C) Regline − − 0.3 %
Load Regulation (IO = 0 mA to 800 mA, TA = 25°C) Regload − − 0.5 %
Dropout Voltage (IO = 490 mA) Vin −VO−0.95 1.1 V
Ripple Rejection (f = 120 Hz) RR 55 − − dB
Maximum Output Current (Vin = 5.0 V) I(max) 800 − − mA
Bias Current (Vin = 4.25 V, IO = 0 mA) IB−5.0 to 3.0 8.0 mA
Minimum Load Current to maintain Regulation (Vin = 15 V) IL(min) −−0 mA
IO, OUTPUT LOAD CURRENT (mA)
in
VO
−V
Figure 1. Dropout Voltage versus
Output Load Current
1.5
1.3
1.1
0.9
0.7
0.5 0 200 400 600 800 1000
Figure 2. Transient Load Regulation
, DR
P
UT V
LTA
E
V
TJ = 25°C
20 ms/DIV
Vin = 5.0 V
CO = 10 mF
TA = 25°C
, OUTPUT CURRENTI O
VO, OUTPUT VOLTAGE DEVIATION∆