POWER LCM600 600 Watt Bulk Front End Data Sheet Total Power: 600 W # of Outputs: Single Outputs: 12 to 60 V Optional 5.0 V standby SPECIAL FEATURES 600 W output power Low Cost 2.4" x 4.5" x 7.5" 7.41 W/cu-in Industrial/Medical safety -40 C to 70 C with derating Optional 5 V @ 2 A Housekeeping High Efficiency: 89% typical Variable speed "Smart Fans" DSP controlled front end Conformal coat option 20% adjustment range Margin programming OR-ing FET Terminal block input option Electrical Specifications Input Input range: 85 - 264 Vac (Operating) 115/230 Vac (Nominal) Input through standard IEC connector/ TERMINAL BLOCK Frequency: 47 - 440 Hz, Nominal 50/60 Input fusing: Internal 10 A fuses, both lines fused Inrush current: 25 A peak, either hot or cold start Power factor: 0.99 typical, meets EN61000-3-2 Harmonics: Meets IEC 1000-3-2 requirements Input current: 8 A RMS max input current, at 100 Vac Hold up time: 20 ms minimum for Main O/P, at full rated load Efficiency: > 89% at full load Leakage current: < 0.3 mA at 264 Vac ON/OFF power switch: N/A SAFETY Power line transient: MOV directly after the fuse UL 60950-1 1598/1433 60601-1 CSA 60950-1 VDE 60950-1 60601 China CCC CB Scheme Report/Cert Isolation: Isolation: PRI-Chassis 2500 Vdc Basic PRI-SEC 4000 VAC Reinforced 2xMOPP SEC-Chassis 500 Vdc EMI Class B EN61000 Immunity LCM600Q Efficiency Without the 5 Vsb 92.00 90.00 88.00 86.00 Efficiency % COMPLIANCE 100 Vac 230 Vac 84.00 82.00 80.00 78.00 76.00 25 50 75 Loading % 100 LCM600 Data Sheet Electrical Specifications Output Output rating: See ordering information table 85 - 264 Vac Set point: 0.5% 85 - 264 Vac Total regulation range: Main output 2% 5 Vsb 1% Combined line/load/transient when measured at output terminal Rated load: 600 W maximum Derate linear to 50% from 50 C to 70 C Minimum load: Main output @ 0.0 A 5 Vsb @ 0.0 A No loss of regulation Output noise (PARD): 1% max p-p 50 mV max p-p Main output 5 Vsb output Measured with a 0.1 F Ceramic and 10 F Tantalum Capacitor on any output, 20 MHz Output voltage overshoot: No overshoot/undershoot outside the regulation band during on or off cycle Transient response: < 300 Sec 50% load step @ 1 A/s Step load valid between 10% to 100% of output rating Recovery time to within 1% of set point at onset of transient Max units in parallel: Up to 10 Short circuit protection: Protected, no damage to occur Bounce mode Remote sense: Compensation up to 500 mV Output isolation: Standard per safety requirements Forced load sharing: To within 10% of all shared outputs Analog sharing control Overload protection (OCP): 105% to 125% 120% to 170% Main output 5 Vsb output Overvoltage protection (OVP): 125% to 145% 110% to 125% 12 V output 5 Vsb output Overtemp protection: 10 - 15 C above safe operating area Both PFC and output converter monitored Fan Fault Protection: For-N option only. Will shutdown output and DC_OK Environmental Specifications Operating temperature: -40 C to +70 C, linear derating to 50% from 50 C to 70 C Storage temperature: -40 C to +85 C Humidity: 20 to 90%, non-condensing. Operating. Conformal coat option available Fan noise: < 45 dBA, 80% load at 30 C "-N" Low Noise Option < 35 dBA, 80% Load at 30 C Altitude: Operating - 16,404.2 feet Storage - 30,000 feet Shock: MIL-STD-810F 516.5, Procedure I, VI. Storage Vibration: MIL-STD-810F 514.5, Cat. 4, 10. Storage Ordering Information Model Number* Output Nominal Output Voltage Set Point Set Point Tolerance LCM600L 12 V 12 V LCM600N 15 V 15 V LCM600Q 24 V LCM600U 36 V Current Adjustment Range Min Max Output Ripple P/P (0-50 C) Max Continuous Power Combined Line/ Load Regulation 0.5% 9.6 - 14.4 V 0A 52 A 120 mV 600 W 2% 0.5% 12.0 - 19.5 V 0A 44 A 150 mV 600 W 2% 24 V 0.5% 19.2 - 28.8 V 0A 27 A 240 mV 600 W 2% 36 V 0.5% 28.8 - 43.2 V 0A 16.7 A 240 mV 600 W 2% 14 A 280 mV 600 W 2% LCM600W 48 V 48 V 0.5% 38.4 - 57.6 V 0A *Note: Add "-T" for terminal block instead of IEC input Add "-N" for low noise model on 12 V or 24 V models Add "-4" for 5 V Standby output Add "-A" will be automatically added to all orders to denote new Aesthetics style chassis unless otherwise specified Example: a 24 V with terminal block, low noise and standby with new Aesthetics would be LCM600Q-T-N-4-A LCM600 Data Sheet Pin Assignment Signals Name Description Pin Number(s) +Vout Power rail SK4 GND Power GND SK5 Signals Name Description SK2 Pin Number A2 EEPROM Address 1 -VPROG Return connection of external supply for Margin Programming 2 A1 EEPROM Address 3 -Vsense Remote Sense Return 4 ISHARE Load share voltage 5 A0 EEPROM Address 6 SDA1 Serial Data Signal (I2C) 7 +VPROG Positive connection of external supply for Margin Programming 8 SCL1 Serial Clock Signal (I2C) 9 +Vsense Remote Sense Positive 10 5VSB 5V standby 11 GND 5V standby Return 12 5VSB 5V standby 13 G_DCOK_C Global DCOK Collector 14 GPIOA6 EEPROM Write Protect 15 G_DCOK_E Global DCOK Emitter (GND) 16 GND Return Ground for output signal and I2C communication 17 G_ACOK_C Global ACOK Collector 18 INH_EN Turn Off Main Output 19 G_ACOK_E Global ACOK Emitter (GND) 20 Note: Mating connector for SK2 is LANDWIN CI0120P1HD0-LF Signal Output Signal Connectors (SK2) SK2 Mating Connector: JST Part Number PHDR-20VS; Contact Pins: JST Part Number SPHD-001T-P0.5 LED INDICATORS 2 provided are clearly visible up to a 45 degree offset from vertical with office environment ambient lighting. The status is reflected in the indicator color. The DC_OK LED LED is bicolor. It shall light green if the DC output is within specification, and amber if the output falls out of specification. The AC_OK LED LED is green if the AC is within specification and off when out of specification. Note: With 5 V standby, Amber also indicates that PSU is in standby mode/output off. CONTROL SIGNALS AC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided. DC_OK Open collector 0.5 V maximum at 10 mA. Both emitter and collector access provided. DC_OK will de-assert when output is loss due to OCP, OVP, OTP, or Fan Fault (for -N option). PS_INHIBIT/ENABLE Signal 0.0 - 0.5 V contact closure, output OFF LCM600 Data Sheet Ordering Information LCMXXXXY - A Case Size - B - C - ### Input Termination Acoustic Noise Option Codes Hardware Code Blank = IEC connector Blank = Standard Blank = No Options Factory Assigned for Modiefied standards T = Terminal Block N = Low Noise Fan 1 = Conformal Coat 1-Phase input where XXXX = 600 = 2.4" x 4.5" x 7.5", 600W Voltage Code Y = 4 = 5 V Standby Code 5 = Opt 1 + 4 L 12 N 15 Q 24 U 36 W 48 Mechanical Drawings New Mechanical Reference Drawing: Weight: 2.84 lbs (1.29 Kg) (18.5) SEE DETAIL A 9.5 9.5 GROUND 114.3 0.5 RECOMMENDED SCREW TORQUE: M3.5 x 0.6P = 6 - 8kgf-cm M4.0 x 0.7P = 8 - 10kgf-cm Note 7 RECOMMENDED SCREW TORQUE: M3.5x0.6P = 6-8kgf-cm M4.0x0.7P = 8-10kfg-cm NEUTRAL LIVE DETAIL A SCALE 1.500 Note 8 INPUT: TERMINAL BLOCK TYPE. M3.5 SCREW TORQUE VALUE OF 12kgf-cm USING WIRE GAUGE 22-19 (9.5mm CENTERS) SCREW-MC PHILIP PAN WITH WASHER M4x8 BRAND LOGO 41 (2X)6 0.5 (2X)22 0.5 SK2 SIGNAL CONNECTOR - 20WAY (2X)47 0.5 SK4 & SK5 LED (AC OK) LED (DC/OK FAIL) (8X) MOUNTING LOCATIONS BOTH SIDES M4X0.7P THREAD SEE NOTE 7 50 SEE DETAIL B 62 1 INPUT TERMINAL BLOCK SEE NOTE 8 SEE DETAIL C (TRIMPOT LOCATION) 16.8 MOUNTING LOCATIONS SCREW PENETRATION DEPTH IS 4.6 mm MAX. (212.2 ref) 190.5 0.5 (2X)10.6 (2X)182.5 0.5 50 (2X)177.5 0.5 DETAIL B AC INLET VERSION NOTE: OPTIONAL BARRIER STRIP OUTPUT TERMINAL AVAILABLE OPTIONAL MOLEX TYPE CONNECTOR OUTPUT AVAILABLE 11.15 0.5 17.65 0.5 (2X) 94.45 0.5 (2X)10 0.5 VOLTAGE ADJUSTMENT: CLOCKWISE - INCREASE VOLTAGE COUNTER CLOCKWISE - DECREASE VOLTAGE DETAIL C (TRIMPOT LOCATION) (4X) MOUNTING LOCATIONS M4X0.7P THREAD SEE NOTE 7 LCM600 Data Sheet Mechanical Drawings - Terminal Block Input Old Mechanical Reference Drawing: Weight: 2.84 lbs (1.29 Kg) 190,5 0,5 SEE DETAIL A 18,5 REF 9,5 GROUND 9,5 SEE DETAIL B (TRIMPOT LOCATION) NUETRAL 12,8 LIVE 32,8 114,3 0,5 16,8 Note 7 RECOMMENDED SCREW TORQUE: M3.5x0.6P = 6-8kgf-cm M4.0x0.7P = 8-10kfg-cm DETAIL A SCALE 8:5 SCREW-MC PHILIP PAN WITH EXT-T WASHER M3.5 x P0.6 x 6 SK2 SIGNAL CONNECTOR - 20WAY PROVISION FOR FUTURE LABEL REQUIREMENTS (8X) MOUNTING LOCATIONS BOTH SIDES M4X0.7P THREAD SEE NOTE 7 40,2 15,75 POS - SK4 NEG - SK5 (2X)22 0,5 61 0,5 LED (DC/OK FAIL) LED (AC OK) PRODUCT LABEL (2X)47 0,5 INPUT TERMINAL BLOCK SEE NOTE 8 (2X)6 0,5 (2X)10,6 (2X)182,5 0,5 (2X)177,5 0,5 VOLTAGE ADJUSTMENT: CLOCKWISE - INCREASE VOLTAGE COUNTER CLOCKWISE - DECREASE VOLTAGE DETAIL B (TRIMPOT LOCATION) 11,15 0,5 17,65 0,5 (2X)94,45 0,5 (2X)10 0,5 (4X) MOUNTING LOCATIONS M4X0.7P THREAD SEE NOTE 7 50 LCM600 Data Sheet NOISE (dBA Low Noise VS Non-Low Noise LCM600 Model 60.0 58.0 56.0 54.0 52.0 50.0 48.0 46.0 44.0 42.0 40.0 38.0 36.0 34.0 32.0 30.0 25 Deg Ambient NON-Low noise version Low noise version 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 25 27.5 30 32.5 35 37.5 40 42.5 45 47.5 50 47.5 50 LOAD (A) 60.0 50 Deg Ambient 58.0 56.0 54.0 52.0 NOISE (dBA 50.0 48.0 46.0 44.0 42.0 40.0 NON-Low noise version 38.0 Low noise version 36.0 34.0 32.0 30.0 0 2.5 5 7.5 10 12.5 15 17.5 20 22.5 NON-Low noise version 25 LOAD (A) 27.5 30 32.5 35 37.5 40 42.5 45 Low noise version 25C ambient 50C ambient 25C ambient 50C ambient LOAD (A) fan (V) RPM noise (dbA) fan (V) RPM noise (dbA) PWM LOAD (A) RPM noise (dbA) LOAD (A) RPM noise (dbA) 0 6.254 3558.0 40.9 6.228 3460.9 39.9 0% 0 3028 35.2 0 3180 36.0 2.5 6.257 3559.8 41.0 6.228 3460.9 39.9 5% 2.5 3028 35.2 2.5 3300 36.7 5 6.262 3562.0 41.0 6.230 3494.3 40.1 10% 5 3028 35.2 5 3300 36.7 7.5 6.263 3562.0 41.0 6.242 3526.6 40.1 15% 7.5 3060 35.4 7.5 3360 37.0 10 6.242 3528.9 40.5 6.242 3526.6 40.1 20% 10 3028 35.2 10 3360 37.0 12.5 6.251 3530.9 40.6 6.237 3515.6 40.4 25% 12.5 3028 35.2 12.5 3360 37.0 15 6.251 3538.3 40.7 6.229 3504.9 40.2 30% 15 3060 35.4 15 3360 37.0 17.5 6.226 3538.2 40.7 6.205 3482.8 39.4 35% 17.5 3060 35.4 17.5 3388 37.2 20 6.223 3541.0 40.7 6.217 3490.1 40.0 40% 20 3028 35.2 20 3388 37.2 22.5 6.242 3545.1 40.8 6.227 3493.8 40.1 45% 22.5 3028 35.2 22.5 3540 38.0 25 6.253 3553.9 40.9 6.234 3504.3 40.2 50% 25 3060 35.4 25 3840 39.2 27.5 6.254 3564.1 41.0 6.212 3501.7 40.2 55% 27.5 3028 35.2 27.5 4104 40.2 30 6.253 3552.2 40.9 6.642 3787.4 44.1 60% 30 3028 35.2 30 4408 41.4 32.5 6.264 3559.7 41.0 7.893 4652.3 48.0 65% 32.5 3060 35.4 32.5 4736 42.7 35 6.262 3559.6 41.0 9.153 5463.4 50.0 70% 35 3060 35.4 35 5184 44.5 37.5 6.262 3560.8 41.0 11.035 6600.2 52.0 75% 37.5 3060 35.4 37.5 5728 46.4 40 6.262 3559.8 41.0 11.605 6993.9 53.2 80% 40 3060 35.4 40 6688 49.5 42.5 7.637 4521.2 47.8 11.608 6997.2 53.2 85% 42.5 3420 37.4 42.5 7560 51.8 45 8.919 5362.2 49.3 11.608 6997.2 53.2 90% 45 3868 39.3 45 7584 51.9 47.5 10.068 6139.5 51.0 11.608 6997.2 53.2 95% 47.5 4376 41.3 47.5 7584 51.9 50 11.362 6893.4 52.8 11.608 6997.2 53.2 100% 50 5040 43.9 50 7584 51.9 LCM600 Data Sheet Accessories PIN 20 PIN 19 PIN 2 PIN 3 PIN 1 300 5 mm Order kit part number 73-788-001 for control connector interface with .3m wires attached PIN 20 PIN 19 PIN 2 PIN 3 PIN 1 Order kit part number 73-788-002 for control connector interface with unloaded housing and 20 pins Miscellaneous Specifications BURN-IN 100% Burn-in at 45 C, at 80 - 90 % load. Duration of burn-in determined by Quality Assurance Procedures. MTBF The power supply has a minimum MTBF of 300K hours using the Bell core 332, issue 6 specification @ 25 C and 40 C, ambient, at full load. With the power supply installed in a system in a 25 C ambient environment and operating at full load, capacitor life shall be 10 years, minimum for ALL electrolytic capacitors contained within this power supply. The power supply shall demonstrate a MTBF level of > 500,000 hours. QUALITY ASSURANCE Full QAV testing shall be conducted in accordance with Artesyn Embedded Technologies Standards with reports available upon request. WARRANTY Artesyn Embedded Technologies shall warrant the power supply to be free of defects in materials and workmanship for a minimum period of three years from the date of shipment, when operated within specifications. The warranty shall be fully transferable to the end owner of the equipment powered by the supply. WORLDWIDE OFFICES Americas Europe (UK) Asia (HK) 2900 S.Diablo Way Tempe, AZ 85282 USA +1 888 412 7832 Waterfront Business Park Merry Hill, Dudley West Midlands, DY5 1LX United Kingdom +44 (0) 1384 842 211 14/F, Lu Plaza 2 Wing Yip Street Kwun Tong, Kowloon Hong Kong +852 2176 3333 While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. (c) 2014 Artesyn Embedded Technologies, Inc. www.artesyn.com For more information: www.artesyn.com/power For support: productsupport.ep@artesyn.com LCM600 DS Rev. 01-14-15