TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES
KEY FEATURES
*Universal input
*Built-in EMI filter
*Optional remote sense on main output
*Optional constant current charger
*Optional±12VDC/±24VDC/±48VDC input
*Optional cover
*Optional constant current change (for single output)
APPLICATIONS
*
Telecommunications/Business machines
*Computer peripherals/Medical instruments
*Test & industrial equipments
ELECTRICAL SPECIFICATIONS
INPUT
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------38A typical, Cold start @25,115VAC
*Efficiency------------65%~85% typical at full load
*EMI filter------------ FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power----90W convection (Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5 % per inquiry)
120W
90W
60W
30W
0W
45W
Power Derating Curve
0 10 20 30 40 50
60
70
Ambient Temperature(
°
°°
°
C)
Natural
Convection
Cooling
Output
Power
(Watts)
EMI & EMC
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE, EN61000-3-2 (Class A) and –3 ; EN61000-4-2,
-3 , -4 , -5 , -6 and -11
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601(EMI Class A)(COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to
50ambient; derate each output at 2.5% per
degree from 50to 70
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25ambient
conditions
TOTAL POWER INT'L. TEL:877-646-0900 FAX:978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-1-
TOTAL POWER INT'L
TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES
MODEL OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
SINGLE OUTPUT MODEL SELECTION CHART
TPS100-10
+5V
±10% Typical
18A 29.7A 0A
±3%
±1%
150W Typical
TPS100-11 +12V ±10% Typical 7.5A 12.4A 0A ±3% ±1% 150W Typical
TPS100-12
+15V
±10% Typical
6A 9.9A 0A
±3%
±1%
150W Typical
TPS100-13 +24V ±10% Typical 3.75A 6.2A 0A ±3% ±1% 150W Typical
TPS100-14
+48V
±10% Typical
1.875A 3.1A 0A
±3%
±1%
150W Typical
TPS100-15 +13.5V ±10% Typical 6.66A 10.9A 0A ±3% ±1% 150W Typical
TPS100-16
+56V
±10% Typical
1.6A 2.6A 0A
±3%
±1%
150W Typical
TPS100-17 +18V ±10% Typical 5A 2.6A 0A ±3% ±1% 150W Typical
TPS100-18
+3.3V
±10% Typical
25A 41.3A 0A
±5%
±1.5%
150W Typical
DUAL OUTPUT MODEL SELECTION CHART
+5 V ±10% Typical 10A 16.5A 1A ±5% ±1%
TPS100-20 +12V Fixed 4.2A 6.9A 0.42A ±5% ±1% 150W Typical
+5 V ±10% Typical 10A 16.5A 1A ±5% ±1%
TPS100-21 +24V Fixed 2.2A 3.6A 0.22A ±5% ±1% 150W Typical
+5 V ±10% Typical 10A 16.5A 1A ±5% ±1%
TPS100-22 - 5 V Fixed 10A 16.5A 1A ±5% ±1% 150W Typical
+12V ±10% Typical 4.2A 6.9A 0.42A ±5% ±1%
TPS100-23 - 12 V Fixed 4.2A 6.9A 0.42A ±5% ±1% 150W Typical
+15 V ±10% Typical 3.4A 5.6A 0.34A ±5% ±1%
TPS100-24 - 15 V Fixed 3.4A 5.6A 0.34A ±5% ±1% 150W Typical
+3.3V ±10% Typical 17A 28A 1.7A ±5% ±1.5%
TPS100-25 +12 V Fixed 1A 1.6A 0.1A ±5% ±1% 150W Typical
+ 5 V ±10% Typical 1A 1.6A 0.1A ±5% ±1%
TPS100-26 +48V Fixed 2A 3.3A 0.2A ±5% ±1% 150W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
+ 5V ±10% Typical 10A 16.5A 1A ±5% ±1%
TPS100-30 +12V Fixed 4A 6.6A 0.4A ±5% ±1%
- 5 V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5V ±10% Typical 10A 16.5A 1A ±5% ±1%
TPS100-31 +12V Fixed 4A 6.6A 0.4A ±5% ±1%
-12V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5V ±10% Typical 10A 16.5A 1A ±5% ±1%
TPS100-32 +15V Fixed 2.8A 4.6A 0.28A ±5% ±1%
-15V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5V ±10% Typical 14A 23.1A 1.4A ±5% ±1%
+15V Fixed 2A 3.3A 0.2A ±5% ±1%
TPS100-33
- 5 V Fixed 0.5A 0.8A 0.05A ±10% ±1%
150W Typical
+ 5V ±10% Typical 13A 21.5A 1.3A ±5% ±1%
+15V Fixed 2A 3.3A 0.2A ±5% ±1%
TPS100-34
-12V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5 V ±10% Typical 9A 14.9A 0.9A ±5% ±1%
+24V Fixed 2A 3.3A 0.2A ±5% ±1%
TPS100-35
-12V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5V ±10% Typical 9A 14.9A 0.9A ±5% ±1%
+12V Fixed 3.5A 5.8A 0.35A ±5% ±1%
TPS100-36
- 12V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5V ±10% Typical 9A 14.9A 0.9A ±5% ±1%
+12V Fixed 3.5A 5.8A 0.35A ±5% ±1%
TPS100-37 +24V Fixed 0.6A 1A 0.06A ±10% ±1%
150W Typical
+ 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1%
+12V Fixed 2A 3.3A 0.2A ±5% ±1%
TPS100-38 +48V Fixed 1A 1.6A 0.1A ±10% ±1%
150W Typical
TOTAL POWER INT'L. TEL:877-646-0900 FAX:978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-2-
TPS100 SWITCHING MODE 90W U CHANNEL POWER SUPPLIES
MODEL OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
QUAD OUTPUT MODEL SELECTION CHART
+ 5V ±10% Typical 10A 16.5A 1A ±5% ±1%
+12V Fixed 3.5A 5.8A 0.35A ±5% ±1%
- 12V Fixed 0.5A 0.8A 0.05A ±10% ±1%
TPS100-40
- 5 V Fixed 0.5A 0.8A 0.05A ±10% ±1%
150W Typical
+ 5V ±10% Typical 10A 16.5A 1A ±5% ±1%
+12V Fixed 3A 5A 0.3A ±5% ±1%
- 12V Fixed 1A 1.6A 0.1A ±10% ±1%
TPS100-41
- 5 V Fixed 1A 1.6A 0.1A ±10% ±1%
150W Typical
+ 5V ±10% Typical 10A 16.5A 1A ±5% ±1%
+12V Fixed 2A 3.3A 0.2A ±5% ±1%
- 15V Fixed 1A 1.6A 0.1A ±10% ±1%
TPS100-42
+15V Fixed 1A 1.6A 0.1A ±10% ±1%
150W Typical
+ 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1%
+12V Fixed 2.5A 4.1A 0.25A ±5% ±1%
-15V Fixed 1A 1.6A 0.1A ±10% ±1%
TPS100-43
- 12V Fixed 1A 1.6A 0.1A ±10% ±1%
150W Typical
+ 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1%
+12V Fixed 1A 1.6A 0.1A ±5% ±1%
- 12V Fixed 1A 1.6A 0.1A ±10% ±1%
TPS100-44
+48V Fixed 1A 1.6A 0.1A ±10% ±1%
150W Typical
+ 5V ±10% Typical 6A 9.9A 0.6A ±5% ±1%
+12V Fixed 2A 3.3A 0.2A ±5% ±1%
- 12V Fixed 1A 1.6A 0.1A ±10% ±1%
TPS100-45
+24V Fixed 1.5A 2.5A 0.15A ±10% ±1%
150W Typical
+ 5V ±10% Typical 2.5A 4.1A 0.25A ±5% ±1%
+12V Fixed 1A 1.6A 0.1A ±5% ±1%
- 12V Fixed 2A 3.3A 0.2A ±10% ±1%
TPS100-46
+36V Fixed 1.5A 2.5A 0.15A ±10% ±1%
150W Typical
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, 0.1μF and 47μF Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version; 50% derated if 12 VDC input version; 25% derated if additional cover.
TOTAL POWER INT'L TEL:877-646-0900 FAX:978-453-7395
E-mail:sales@total-power.com http://www.total-power.com
-3-