457 FIBER SENSORS Small U-shaped Micro Photoelectric Sensor Amplifier Built-in PM-44 SERIES PM-54 SERIES Related Information General terms and conditions............ F-17 Glossary of terms / General precautions........ P.1359~ / P.1405 Sensor selection guide................... P.441~ Korea's S-mark............................... P.1410 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS AREA SENSORS Recognition Certified (Some models only) LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic-electric-works.net/sunx PNP output type available STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Enables space saving and quick installation! Equipped with two independent outputs Quick fitting hook-up connector All models are equipped with two independent outputs Light-ON and Dark-ON. Hence, one model suffices even if the output is to be used differently, depending upon the location of use. Also, since two independent outputs have been provided, cumbersome handling of the output conversion control input, or fear of logic inversion due to a cable break, is eliminated. The sensor can be connected to the existing wiring as it is. Easy to maintain connector type models are available. Its exclusive connector is the hookup connector. Since only crimping with exclusive pliers is to be done, cumbersome soldering or insulation is absolutely not required. Further, connector attached cable is also available. Example of connection with a commercial intermediate connector Commercial intermediate connector Selection Guide U-shaped Convergent Reflective PM-24 PM-44/PM-54 Quick connection to the sensor. +V 0V Output 1 (Light-ON) Output 2 (Dark-ON) PM-64 Crimp the connector on the cable. Just connect the cable of the used output (either Light-ON or Dark-ON). To PLC Connected device side can be left as it is. Note: Ensure to insulate the unused output wire. APPLICATIONS Sensing the starting point and overrun of a moving body Overrun sensing Dog Wide model variety A wide variety of 12 shapes and 24 models is available. You may select from this wide range to suit the mounting conditions. Starting point sensing Meets global requirements Conforms to Europe's EMC Directive and obtains UL Recognition. The NPN output type with cable (excluding 3 m 9.843 ft cable length type) has also obtained Korea's Smark certification. Both, NPN and PNP output models are available. Overrun sensing Starting point and overrun is sensed using the dog on the base. Small U-shaped Micro Photoelectric Sensor PM-44 SERIES PM-54 SERIES ORDER GUIDE 458 FIBER SENSORS LASER SENSORS Type Appearance (mm in) Sensing range K type 7 0.276 26.2 1.031 25.4 1.000 T type 26.2 1.031 L type 26 1.024 With cable Y type 13.4 0.528 F type NPN open-collector transistor PM-K44P PNP open-collector transistor MICRO PHOTOELECTRIC SENSORS AREA SENSORS PM-T44 NPN open-collector transistor PM-T44P PNP open-collector transistor PM-L44 NPN open-collector transistor PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 18.5 0.728 25.5 1.004 PM-L44P PNP open-collector transistor PM-Y44 NPN open-collector transistor PM-Y44P PNP open-collector transistor PM-F44 NPN open-collector transistor PM-F44P PNP open-collector transistor PM-R44 NPN open-collector transistor SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE 13.2 0.520 26.2 1.031 13.7 0.539 R type 13.2 0.520 26.2 1.031 13.7 0.539 PHOTOELECTRIC SENSORS SENSOR OPTIONS 15.5 0.610 K type PM-K44 Output operation 15.5 0.610 26 1.024 T type Output LIGHT CURTAINS 13.7 0.539 Small Model No. 5 mm 0.197 in (fixed) 7 0.276 22.2 0.874 25.4 1.000 13.7 0.539 26 1.024 22.2 0.874 PM-R44P PNP open-collector transistor PM-K54 NPN open-collector transistor PM-K54P PNP open-collector transistor LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES Incorporated with 2 outputs: Light-ON / Dark-ON ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS PM-T54 NPN open-collector transistor PM-T54P PNP open-collector transistor PM-L54 NPN open-collector transistor Convergent Reflective PM-L54P PNP open-collector transistor PM-64 PM-Y54 NPN open-collector transistor PM-Y54P PNP open-collector transistor PM-F54 NPN open-collector transistor PM-F54P PNP open-collector transistor PM-R54 NPN open-collector transistor PM-R54P PNP open-collector transistor Selection Guide 13.4 0.528 F type 14.5 0.571 15.5 0.610 Y type L type 15.5 0.610 26 1.024 21.5 0.846 PM-24 13.2 0.520 13.7 0.539 22.2 0.874 13.2 0.520 R type With connector U-shaped 13.7 0.539 22.2 0.874 PM-44/ PM-54 459 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Small U-shaped Micro Photoelectric Sensor PM-44 SERIES PM-54 SERIES ORDER GUIDE 3 m 9.843 ft cable length type 3 m 9.843 ft cable length type (standard: 1 m 3.281 ft) is also available. When ordering this type, suffix "-C3" to the model No. (e.g.) 3m 9.843 ft cable length type of PM-K44 is "PM-K44-C3". AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS OPTIONS Designation Connector SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Model No. CN-14 Connector for soldering CN-14H This connector can be hooked-up on 0.08 to 0.2 mm2 cable simply in one grip. Wire diameter: o0.7 to o1.2 mm o0.028 to o0.047 in CN-14H-2 Suitable for UL standard cable. This connector can be hooked-up on 0.18 to 0.22 mm2 cable simply in one grip. Wire diameter: o1.2 to o1.52 mm o0.047 to o0.060 in Hook-up connector MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE CN-14H-C1 Connector attached cable LASER MARKERS CN-14H-C3 PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective PM-64 PM-24 PM-44/ PM-54 Hook-up pliers Description CN-HP Length: 1 m 3.281 ft Net weight: 20 g approx. Length: 3 m 9.843 ft Net weight: 65 g approx. For the connector type, with 0.18 mm2 4-core cabtyre cable Cable diameter: o3.8 mm o0.150 in These are exclusive pliers for hook-up connectors CN-14H and CN-14H-2. Connector Hook-up connector Connector attached cable Hook-up pliers * CN-14 * CN-14H * CN-14H-2 * CN-14H-C1 * CN-14H-C3 * CN-HP Small U-shaped Micro Photoelectric Sensor PM-44 SERIES PM-54 SERIES SPECIFICATIONS Model No. Item FIBER SENSORS With cable With connector NPN output PM-44 PM-54 PNP output PM-44P PM-54P Sensing range 5 mm 0.197 in (fixed) Minimum sensing object 0.05 mm 0.002 in or less Repeatability 0.03 mm 0.001 in or less Supply voltage Output PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS 15 mA or less NPN open-collector transistor * Maximum sink current: 50 mA * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 0.7 V or less (at 50 mA sink current) 0.4 V or less (at 16 mA sink current) Utilization category PNP open-collector transistor * Maximum source current: 50 mA * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 0.7 V or less (at 50 mA source current) 0.4 V or less (at 16 mA source current) DC-12 or DC-13 Output operation Under light received condition: 20 s or less, Under light interrupted condition: 100 s or less (Response frequency: 1 kHz or more) (Note 2) Operation indicator Vermilion LED (lights up under light received condition) Pollution degree 3 (Industrial environment) Ambient temperature PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Incorporated with 2 outputs: Light-ON / Dark-ON Response time MICRO PHOTOELECTRIC SENSORS LIGHT CURTAINS 5 to 24 V DC 10 % Ripple P-P 10 % or less Current consumption PHOTOELECTRIC SENSORS AREA SENSORS 0.8 x 1.8 mm 0.031 x 0.071 in opaque object Hysteresis Environmental resistance LASER SENSORS Small Type 460 MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE -25 to +55 C -13 to +131 F (No dew condensation or icing allowed), Storage: -30 to +80 C -22 to +176 F Ambient humidity LASER MARKERS 35 to 85 % RH, Storage: 35 to 85 % RH Ambient illuminance Fluorescent light: 1,000 x at the light-receiving face EMC PLC / TERMINALS EN 60947-5-2 Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure HUMAN MACHINE INTERFACES Insulation resistance 50 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 2,000 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each ENERGY CONSUMPTION VISUALIZATION COMPONENTS 15,000 m/s2 acceleration (1,500 G approx.) in X, Y and Z directions for three times each FA COMPONENTS Shock resistance Emitting element Infrared LED (Peak emission wavelength: 940 nm 0.037 mil, non-modulated) Material Enclosure: PBT, Slit cover: Polycarbonate, Terminal part [PM-54(P) only]: Solder plated 0.09 mm2 4-core cabtyre cable, 1 m 3.281 ft long Cable Cable extension - MACHINE VISION SYSTEMS UV CURING SYSTEMS Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. Weight Net weight: 15 g approx. Net weight: 3 g approx. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) The response frequency is the value when the disc, given in the figure below, is rotated. Disc Disc 1.8 mm 0.071 in Selection Guide U-shaped Convergent Reflective PM-64 t = 0.2 mm 0.008 in 1.6 mm 0.063 in 1.6 mm 0.063 in PM-24 PM-44/ PM-54 461 Small U-shaped Micro Photoelectric Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS PM-44PM-54 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES Wiring diagram Brown Color code for cable type (Note 2) (Brown) +V ZD1 Sensor circuit LIGHT CURTAINS NPN output type I/O circuit diagram MICRO PHOTOELECTRIC SENSORS AREA SENSORS PM-44 SERIES PM-54 SERIES ZD2 (Black) Output 1 Load (Note 1,3) 50 mA max. (White) Output 2 (Note 1,3) Tr1 Tr2 Load + 5 to 24 V DC 10 % - ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective PM-64 5 to 24 V DC 10 % Color code Output operation Output 1 Black Light-ON Output 2 White Dark-ON PM-44PPM-54P PNP output type I/O circuit diagram Wiring diagram Brown Color code for cable type (Note 2) Black ZD1 Tr1 ZD2 50 mA max. (Black) Output 1 (Note 1,3) 50 mA max. Tr2 (White) Output 2 (Note 1,3) Load (Blue) 0 V Internal circuit + Load 5 to 24 V DC 10 % - Blue Symbols ... ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : PNP output transistor SENSING CHARACTERISTICS (TYPICAL) PM-L44(P)/K44(P)PM-L54(P)/K54(P) Sensing position DarkON 7 mm 0.276 in 8.5 mm 0.335 in 2.9 mm 0.114 in LightON 0 Beam axis 1 2 3 0.039 0.079 0.118 Operating point (mm in) 4 0.157 LightON 0 1 2 3 0.039 0.079 0.118 Operating point (mm in) Load - 5 to 24 V DC 10 % Load Output operation Users' circuit Notes: 1) Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage. 2) The color code of the connector attached cable is also the same. 3) Ensure to insulate the unused output wire. DarkON + White PM-24 PM-44/ PM-54 - Symbols ... ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor Sensor circuit HUMAN MACHINE INTERFACES + Output operation Users' circuit (Brown) +V PLC / TERMINALS Load Blue Notes: 1) Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage. 2) The color code of the connector attached cable is also the same. 3) Ensure to insulate the unused output wire. ENDOSCOPE LASER MARKERS Load White 50 mA max. (Blue) 0 V Internal circuit Black 4 0.157 Color code Output operation Output 1 Black Light-ON Output 2 White Dark-ON Small U-shaped Micro Photoelectric Sensor PM-44 SERIES PM-54 SERIES PRECAUTIONS FOR PROPER USE Refer to General precautions. * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Mounting * When fixing the sensor with screws, use M3 screws and the tightening torque should not exceed the values given below. Further, use small, round type plain washers (o6 mm o0.236 in). PM-54(P) Tightening torque 0.5 N*m PHOTOELECTRIC SENSORS Cable extension * Cable extension is possible up to an overall length of 100 m 328.084 ft with a 0.3 mm2, or more, cable. However, since a voltage drop shall occur due to the cable extension, ensure that the power supply voltage at the end of the cable attached to the sensor or at the sensor terminals is within the rating. Total cable length 100 m 328.084 ft * Make sure to connect terminals correctly as the sensor does not incorporate a reverse polarity protection circuit. Further, the output is not incorporated with a short-circuit protection circuit. Do not connect it directly to a power supply or a capacitive load. Faulty wiring may result in damage. PM-44(P) FIBER SENSORS LASER SENSORS All models Model No. 462 Cable attached to sensor or connector terminals +V Extension cable Output 5 to 24 V DC 10 % But, when the overall cable length, including the cable attached to the sensor, is as given below, there is no need to confirm the voltage. Conductor cross-section area of extension cable Total cable length 0.08 to 0.1 mm2 Up to 5 m 16.404 ft 0.2 mm2 Up to 10 m 32.808 ft 0.3 mm2 Up to 20 m 65.617 ft Spring washer Plain washer Outer diameter o6 mm o0.236 in + Supply voltage: 4.5 V or more M3 screws Others * Since the sensor is intended for use inside machines, no special countermeasures have been taken against extraneous light. Take care that extraneous light is not directly incident on the beam receiving section. * Do not use during the initial transient time (50 ms) after the power supply is switched on. AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS - 0V MICRO PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective PM-64 PM-24 PM-44/ PM-54 463 Small U-shaped Micro Photoelectric Sensor PRECAUTIONS FOR PROPER USE FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS Cautions in plugging or unplugging a connector Crimping of hook-up connectors CN-14H and CN-14H-2 * Do not plug or unplug a connector more than 10 times. * Be sure not to give stress more than 5 N to a terminal of both a connector and a sensor. If you do not follow the above cautions, it will cause a poor contact. AREA SENSORS LIGHT CURTAINS INDUCTIVE PROXIMITY SENSORS Refer to General precautions. PM-54PM-54P MICRO PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS PM-44 SERIES PM-54 SERIES 1 Insert a connector straight into a sensor until the connector lug is locked by the sensor hook. CN-14H CN-14H-2 Conductor crosssection area 0.08 to 0.2 mm2 (AWG28 to AWG24) 0.18 to 0.22 mm2 (AWG25 to AWG24) Wire diameter o0.7 to o1.2 mm o0.028 to o0.047 in o1.2 to o1.52 mm o0.047 to o0.060 in Wire insulation material Procedures of plugging or unplugging a connector PARTICULAR USE SENSORS Model No. Item Vinyl chloride or soft polyethylene Hook Lug Wire diameter SENSOR OPTIONS Conductor cross-section area SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS 2 When unplugging, give as much stress as a connector lug can be relieved from a hook. Then unplug it. 5 N or less Crimping method 1 STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS U-shaped PM-64 PM-24 PM-44/ PM-54 Cable sheath 15 mm 0.591 in or more Arrangement of connector terminals +V: +V +V 1 2 0V 1: Output 1 (Light-ON) 2: Output 2 (Dark-ON) (Note) Power supply 0V: 0 V Note: Wire at Pin No.1 or 2 as per requirement. Soldering (Both connector CN-14 and sensor) * If soldering is done directly on the terminals, strictly adhere to the conditions given below. Soldering time Convergent Reflective Lead wire (Do not strip the wire insulation.) Caution: Be sure to hold a connector when plugging or unplugging it. Do not hold a terminal or a cable when plugging or unplugging the connector. Otherwise, it will cause a poor contact. Soldering temperature Selection Guide Strip the cable sheath 15 mm 0.591 in, or more, and insert the wires into the connector insertion holes till the wire tips reach the end. 3 sec. or less Soldering position Sensor +V 1 260 C 500 F or less Refer to the below figure Connector 2 0V +V 1 2 0V 1.5 mm 0.059 in Soldering position 2 Crimp with the exclusive hook-up pliers CN-HP. Notes: 1) When attaching or detaching the connector fitted with a cable, make sure to hold the connector firmly before proceeding. 2) After crimping, do not pull on the cable. Caution: M ake sure to use the exclusive hook-up pliers CN-HP.Commercially available pliers cannot be used. * Prior to using the sensor, affix the cable in a way as to avoid direct stress on the crimped part. Small U-shaped Micro Photoelectric Sensor DIMENSIONS (Unit: mm in) Sensor PM-T44PM-T44P Sensor 2-o3.2 o0.126 mounting holes 1 0.039 6.4 0.252 Operation indicator (Vermilion) 2.9 0.114 6.4 0.252 Beam axis 8.5 0.335 13.8 0.543 26.2 1.031 11 0.433 10.8 0.425 4.3 0.169 3.2 0.126 9.5 0.374 o4.8 o0.189 o2.7 o0.106 cable, 1 m 3.281 ft long 2.5 0.098 Sensor 26 1.024 19 0.748 1 0.039 3.2 0.126 7 0.276 2 0.079 1 0.039 7 0.276 Beam axis 18.5 0.728 10.8 0.425 2-mounting oblong holes 25.5 1.004 Operation indicator (Vermilion) o4.8 o0.189 2.9 0.114 13.4 0.528 7.2 0.283 19 0.748 3.6 0.142 3.3 0.130 6.5 0.256 3.5 0.138 ENDOSCOPE 1 0.039 o4.8 o0.189 2.5 0.098 6.5 0.256 8.5 0.335 26.2 1.031 2 0.079 Operation indicator (Vermilion) 9 0.354 13.2 0.520 6.4 0.252 7 0.276 UV CURING SYSTEMS PM-R44PM-R44P Sensor 3.2 0.126 3.2 0.126 13.7 0.539 13.2 0.520 6.4 0.252 7 0.276 2.9 0.114 9 0.354 7 13.6 0.535 0.276 3.3 0.130 4 0.157 2-o3.5 o0.138 mounting holes o2.7 o0.106 cable, 1 m 3.281 ft long 7 13.6 0.276 0.535 3.3 0.130 4 0.157 2-o3.5 o0.138 mounting holes FA COMPONENTS MACHINE VISION SYSTEMS Selection Guide Beam axis 13.4 0.528 5 2.9 0.197 0.114 10.8 0.425 ENERGY CONSUMPTION VISUALIZATION COMPONENTS 6.4 0.252 3.3 0.130 Sensor 13.7 0.539 Beam axis HUMAN MACHINE INTERFACES Beam axis 12.6 0.496 Beam axis 7 0.276 PLC / TERMINALS 2.9 0.114 2-o3.2 o0.126 mounting holes PM-F44PM-F44P 2.5 0.098 LASER MARKERS o2.7 o0.106 cable, 1 m 3.281 ft long 8.5 15.5 0.335 0.610 MEASUREMENT SENSORS STATIC CONTROL DEVICES Operation indicator (Vermilion) 13.4 0.528 5 0.197 SIMPLE WIRE-SAVING UNITS 2-o3.5 o0.138 mounting holes 15 0.591 10.8 0.425 SENSOR OPTIONS WIRE-SAVING SYSTEMS 7 0.276 Beam axis 2 0.079 o4.8 o0.189 6.4 0.252 Beam axis 8.5 0.335 15.5 9 0.354 0.610 o2.7 o0.106 cable, 1 m 3.281 ft long Sensor o2.7 o0.106 cable, 1 m 3.281 ft long 13.4 0.528 5 0.197 Operation indicator (Vermilion) PM-Y44PM-Y44P 4-R2 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 2 2-mounting 0.079 o4.8 o0.189 oblong holes 19 0.748 PM-L44PM-L44P PRESSURE / FLOW SENSORS Beam axis 26.2 1.031 10.8 0.425 10.3 0.406 AREA SENSORS LIGHT CURTAINS 8.5 0.335 13 0.512 6.2 0.244 2-o3.8 o0.150 mounting holes 4 2 0.157 0.079 Beam axis 13.4 0.528 5 0.197 2.9 0.114 1 0.039 26 1.024 LASER SENSORS MICRO PHOTOELECTRIC SENSORS 7 0.276 3 0.118 Beam axis 19 0.748 13.4 0.528 5 0.197 FIBER SENSORS PHOTOELECTRIC SENSORS 13.7 0.539 3.5 0.138 7 0.276 464 The CAD data in the dimensions can be downloaded from our website. PM-K44PM-K44P 25.4 1.000 19 0.748 PM-44 SERIES PM-54 SERIES U-shaped 7 0.276 13.4 0.528 5 0.197 8.5 0.335 2.5 0.098 PM-64 1 0.039 Beam axis 26.2 1.031 10.8 0.425 2 0.079 o4.8 o0.189 Operation indicator (Vermilion) Convergent Reflective o2.7 o0.106 cable, 1 m 3.281 ft long PM-24 PM-44/ PM-54 465 FIBER SENSORS LASER SENSORS Small U-shaped Micro Photoelectric Sensor PM-44 SERIES PM-54 SERIES DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. PM-K54PM-K54P PHOTOELECTRIC SENSORS Sensor 25.4 1.000 19 0.748 MICRO PHOTOELECTRIC SENSORS 13.7 0.539 7 0.276 Beam axis 2-o3.2 o0.126 mounting holes LIGHT CURTAINS 19 0.748 13.4 0.528 5 0.197 1 0.039 PRESSURE / FLOW SENSORS 2.9 0.114 6.4 0.252 6.4 0.252 13.8 0.543 22.2 0.874 11 0.433 6.8 0.268 PARTICULAR USE SENSORS Operation indicator (Vermilion) Beam axis 8.5 0.335 INDUCTIVE PROXIMITY SENSORS 5 0.197 2-o3.8 o0.150 mounting holes LASER MARKERS PLC / TERMINALS 6.3 0.248 2.5 0.098 PM-L54PM-L54P Sensor 26 1.024 19 0.748 3.2 0.126 1 0.039 7 0.276 14.5 0.571 6.8 0.268 Beam axis 22.2 0.874 6.8 0.268 Operation indicator (Vermilion) 13.4 0.528 MACHINE VISION SYSTEMS 7 0.276 Beam axis 11 0.433 21.5 0.846 6.8 0.268 Operation indicator (Vermilion) 13.4 0.528 5 0.197 6.4 0.252 Beam axis 7.2 0.283 UV CURING SYSTEMS 6.4 0.252 2.9 0.114 Beam axis 8.5 15.5 0.335 0.610 6.5 0.256 12.6 0.496 3.3 0.130 2-o3.2 o0.126 mounting holes PM-F54PM-F54P Selection Guide 3.5 0.138 5 0.197 19 0.748 3.6 0.142 Sensor 2-o3.5 o0.138 mounting holes 7 1 0.276 0.039 Operation indicator (Vermilion) 13.4 0.528 5 0.197 8.5 0.335 15.5 9 0.354 0.610 FA COMPONENTS PM-Y54PM-Y54P 4-R2 R0.079 2-mounting oblong holes 2.9 0.114 ENERGY CONSUMPTION VISUALIZATION COMPONENTS 2-mounting oblong holes Beam axis 5 0.197 HUMAN MACHINE INTERFACES 19 0.748 2.9 0.114 8.5 0.335 5 0.197 STATIC CONTROL DEVICES ENDOSCOPE 13 0.512 3 0.118 Beam axis 13.4 0.528 5 0.197 1 0.039 6.2 0.244 SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS 26 1.024 4.3 0.169 3.2 0.126 5.5 0.217 SENSOR OPTIONS WIRE-SAVING SYSTEMS Sensor 3.5 0.138 7 0.276 AREA SENSORS PM-T54PM-T54P 2.5 0.098 6.5 0.256 3.3 0.130 Sensor PM-R54PM-R54P Sensor Beam axis Beam axis U-shaped Convergent Reflective 2.5 0.098 PM-64 PM-24 PM-44/ PM-54 1 0.039 7 0.276 13.7 0.539 13.4 0.528 5 0.197 7 0.276 13.7 0.539 13.2 0.520 6.4 0.252 7 0.276 2.9 0.114 Beam axis 8.5 0.335 22.2 0.874 6.8 0.268 5 0.197 Operation indicator (Vermilion) 3.2 0.126 9 0.354 7 13.6 0.535 0.276 3.3 0.130 3.2 0.126 13.2 0.520 6.4 0.252 7 0.276 7 13.6 0.276 0.535 3.3 0.130 8.5 0.335 Beam axis 22.2 0.874 6.8 0.268 5 0.197 2-o3.5 o0.138 mounting holes 2-o3.5 o0.138 mounting holes 13.4 0.528 5 0.197 1 0.039 2.9 0.114 9 0.354 2.5 0.098 Operation indicator (Vermilion) Small U-shaped Micro Photoelectric Sensor DIMENSIONS (Unit: mm in) 466 PM-44 SERIES PM-54 SERIES The CAD data in the dimensions can be downloaded from our website. * Terminal part (PM-54, PM-54P) CN-14 Connector (Optional) FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS +V 1 2 1 0.039 1 0.039 1.3 0.051 MICRO PHOTOELECTRIC SENSORS 0V 0.8 0.031 1.6 0.063 2.1 0.083 2.54 2.54 2.54 0.100 0.100 0.100 t 0.3 t 0.012 7.5 0.295 1 0.039 +V 1 2 AREA SENSORS 4.6 0.181 13 0.512 1 1 0.039 0.039 0V (5) (0.197) LIGHT CURTAINS 0V 2 1 +V PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS t 0.4 t 0.016 0.8 0.031 2 0.079 1.6 0.063 6 0.236 (2.54) (0.100) PARTICULAR USE SENSORS (7.62) (0.300) SENSOR OPTIONS CN-14HCN-14H-2 Hook-up connector (Optional) CN-14H-C1CN-14H-C3 Connector attached cable (Optional) SIMPLE WIRE-SAVING UNITS L WIRE-SAVING SYSTEMS (50) (1.969) 2 1 6 0.236 15 0.591 +V 1 2 6 0.236 1 2 MEASUREMENT SENSORS ENDOSCOPE 0V 0V +V (8) (0.315) STATIC CONTROL DEVICES +V 13 0.512 13 0.512 0V 15 0.591 0V 2 1 +V LASER MARKERS o3.8 o0.150 cable PLC / TERMINALS * Length L Model No. Length L CN-14H-C1 1 m 3.281 ft CN-14H-C3 3 m 9.843 ft HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide U-shaped Convergent Reflective PM-64 PM-24 PM-44/ PM-54