Yokogawa Corporation of America
DIN METER SERIES
Meter Product Line-up
Usage Precautions
Specifications
Scale forms and divisions
Standard Specifications
Catalog Numbers
DC Ammeters
DC Voltmeters
Suppressed Meters (DC Ammeters & Voltmeters)
AC Ammeters (Mean Rectifier Type)
AC Voltmeters (Mean Rectifier Type)
AC Ammeters (Moving Iron Type)
AC Voltmeters (Moving Iron Type)
Frequency Meters
Wattmeters
Varmeters
Power Factor Meters
Dimensions and Panel Mountings
Connection Diagrams
Contents
2
3
4
6
8
9
10
13
15
16
17
18
20
22
23
25
27
29
30
Model DN96 DN72
Page
Size
96×96 72×72
Name Suspension
type
Operating
principle Symbol
DC
Ammeters
Taut band
Moving coil
type
9
Pivot & jewel
Voltmeters
Taut band 11
Pivot & jewel
Ammeters,
Voltmeters,
Suppressed meters
Taut band 13
Pivot & jewel
AC
Ammeters
Taut band
Mean
rectifier type
15
Pivot & jewel
Voltmeters
Taut band 16
Pivot & jewel
Ammeters
Pivot & jewel Moving iron
type 17,18,19
Voltmeters
Frequency meters
Taut band Differential
type 20
Pivot & jewel
Wattmeters
1P2W
Taut band
Feedback
time division
multiplier
type
21,22
3P3W Unbal.
3P4W
Bal.
Unbal.
Varmeters
1P2W
23,24
3P3W
Bal.
Unbal.
3P4W
Bal.
Unbal.
Power factor
meters
1P2W Phase
detection
type
25,26
3P3W
Bal.
Unbal. Feedback
time division
multiplier
type
3P4W Unbal.
Remark: shows these meters needs external transducer.
Meter Product Line-up
2
Warning
Indicates usage precautions that must be read to ensure the safety of users and the equipment.
Usage Precautions
1. Usage environment & conditions
Do not use YOKOGAWA DIN meters in locations
such as the following:
Locations where the ambient temperature is
outside the range of 0-45.
Locations where relative humidity is outside the
range of 30-75%.
Locations subject to vibrations or shock impact.
Locations subject to rain, dripping water, or direct
sunlight.
Locations exposed to large amounts of dust, salt,
soot, or corrosive gases
(sulfurous acid gas, ammonia gas, hydrogen
sulfide gas, or other gases that corrode metals of
plastics)
Locations subject to strong external noise or
electromagnetic waves.
Locations subject to large amounts of static
electricity.
Locations subject to large amounts of high
frequencies and waveform distortion(e.g., from
inverters or thyristor circuits)
2. Mounting method
Adhere to safety rule at the construction,
maintenance and inspection
Check the appearance of the packing box and
DIN meters and confirm that there is no damage
If necessary, combine with washers and others
and fasten, in the case of panel boards and
switchboards are thin.
Fasten nuts on clamp panel mount to the proper
torque for the size of screw being used with the
proper tool.
Recommended tightening torque:
M3 screws 0.6N·m
3. Wiring
Adhere to the following rules when connecting
the wires:
When connecting an instrument with accessories,
first make sure none of the wires are live.
The connector terminals on the wires should be
appropriate for the electricity load and terminal
size.
Connect the wires properly as illustrated in the
wiring diagrams of the catalog or on the product
labels.
Attach to terminal cover for safety.
Fasten terminal screws to the proper torque for
the size of screw being used with the proper tool.
Recommended tightening torque:
M3 screws 0.6N·m
M4 screws 1.2N·m
Instruments that are combined with current
transformers (CT) should be properly connected
to the secondary side of the CT. Improper
connection may result in a CT failure, burned
components, or a fire. When the secondary side of a CT
is disconnected, especially while the primary side is
powered, the secondary side terminal will carry a high
voltage which could result in electrical shock. Therefore,
the secondary side should be short-circuited before the
instrument is disconnected.
4. Usage precautions
Use the instrument within the rated specifications.
Failure to do so can cause the equipment to malfunction
or result in a failure.
While the power is on, do not touch any terminals or
open the cover or case.
The current transformer emits heat while powered, so do
not touch it.
5. What to do if the equipment functions abnormally or
fails
If you notice abnormal heating, or a strange odor, noises,
or smoking or if the equipment seems to have failed,
immediately take steps such as cutting off the input.
Next, contact your YOKOGAWA sales office.
6. Maintenance and inspection
To ensure that your instrument operates properly,
perform the following checks on a regular basis:
Check for damage to the instrument or accessories due
to heating or other factors.
Check for loose attachments or screws (always turn off
the power before doing this to ensure safety).
The instrument covers have been coated with an
antistatic agent to block static electricity. Gently wipe dirt
off the cover surfaces with a soft, dry cloth. Do not use a
wet cloth as this will reduce the effects of the antistatic
coating. Do not allow cloths made from synthetic
materials to contact the cover for an extended period of
time, and do not use benzene, paint thinner, or similar
substances. Doing so may cause the cover to become
deformed, discolor it, or cause cracking.
If the indicator reading becomes unstable due to static
electricity, coat the front and back of the cover with a
commercially available antistatic agent.
Instrument service life will vary according to usage
conditions. In general, however, we recommend
replacing the instrument after about 10 years of use.
7. Disposal of product
Panel meters do not contain batteries.
Dispose of panel meters as general industrial waste.
8. For aluminum electrolytic capacitors
Frequency meters use aluminum electrolytic capacitors.
The lifetime of aluminum electrolytic capacitors are
around 10 years when ambient temperatures are 23℃.
If aluminum electrolytic capacitors run down and the
meters are damaged, replace new frequency meters.
Usage Precautions - Safety instructions for DIN meters
3
Specification
Front view(DN72 And DN96 Series Except DN96A22,23,82,83)
Front view (DN96A22,23,82,83)
Numerals
Division
Zero adjust
Bezel
Units
Scale
Pointer
YOKOGAWA lo
g
o
Operating principle
CT/VT ratio
Type Accuracy class
Mounting position
Dielectric strength
Specifications 4
Numerals
Division
Zero adjust
Bezel
Units
Scale
Pointer
YOKOGAWA LOGO
Operating principle
Type
Accuracy class
Mounting
position
Dielectric
strength
Back view(DN72 And DN96 Series Except DN96A22,23,82,83)
Back view(DN96A22,23,82,83)
Set pointer
Note:The double pointer meter does not have a set pointer.
Safety terminal cover
The clear cover is used to prevent touching
the input terminals.
Don’t forget to close this cover.
Object: All DIN series meters.
Set pointerred
Easy to manage, the pointer can
be set to any value.
Safety terminal cover
The clear cover is used to prevent touching
the input terminals.
Don’t forget to close this cover.
Object: All DIN series meters.
Note:Circuit I and II are independent.
5
Scale forms and divisions
Scale form
a) Types of division
Major line Minor line Medium line
b) Standard scale (Except moving iron type)
c) Moving iron type d) Suppressed meters
e) Extended scale (Moving iron type)
Three-fold extended
Two-fold extended
f) Zero-center meter g) Color of scale
h) Multiple-division & multiple-marking
Single-division
double-marking
Double-division
double-marking
Scale Forms and Divisions
Non-linear scales.
Lines near “0” are
omitted because of
limited space and
low usage.
In the case of 4-20mA
current input, when value
to be input is 4mA, the
pointer read 0; when the
value to be input is 0mA,
the pointer points to the
mechanical zero,
Used in measuring the loading
current of the electromotor.
The Colored scales and figures with
red, which are beyond the effective
range. This kind is used to measure
the starting current.
Zero-center: the scale
division is the same as
the standard scale.
Confirm the color is “red, green,
blue or yellow”.
Colored line, colored field:
maximum 2 piece / 2 color.
Colored figure:
maximum 2 piece 1color.
The larger scale is on external
side; the smaller one is on inner
side. Multiple-division is as the
same as the standard scale.
6
Colored
figure
Colored
lined
Colored
field
Linear scales
Scale division
Maximum
scale
value
Value of
per
division
Division
Maximum
scale
value
Value of
per
division
Division
1
10
100
0.02
0.2
2
50 division
4.5
45
450
0.1
1
10
45 division
1.2
12
120
0.05
0.5
5
24 division
5
50
500
0.1
1
10
50 division
1.5
15
150
0.05
0.5
5
30 division
6
60
600
0.2
2
20
30 division
2
20
200
0.05
0.5
5
40 division
7.5
75
750
0.2
2
20
37.5 division
2.5
25
250
0.05
0.5
5
50 division
8
80
800
0.2
2
20
40 division
3
30
300
0.1
1
10
30 division
9
90
900
0.2
2
20
45 division
4
40
400
0.1
1
10
40 division
7
Standard Specifications
Item DN96 DN72
Suspension type Taut band Pivot & jewel Taut band Pivot & jewel
Pointer type Lance type (black color) Lance type(black color)
Bezel color Black Black
Front cover dimensions 96×96mm 72×72mm
Scale length
53mmDN9622,23,82,83
61mm
95mmDN96Series others
The length between element center and
pointer end
33.7mmDN9622,23,82,83
39mm
60.5mmDN96Series others
Full scale deflection angle 90°±2°
Meter mounting position Vertical
Insulation resistance
Between electrical circuit and the case:500V DC/More than 10M
Between current circuit and voltage circuit:500V DC/More than 5M
Dielectric strength
Linemax:500V (Ammeters only)
Between electrical circuit and the case(I/V): 3320V AC for 5S;
Between electrical circuit and case(FREQ., WATT,P.F.,VAR):3320 AC
for 5Sbetween current circuit and case:2600V AC for 5S;
Others2210V AC for 5S;
Between electrical circuit I and II with double pointer meter: 3320V
AC for 5S
Operating temperature range 045
Operating humidity range 3075%RH
Storage temperature range -1050
Storage humidity range 2580%RH
Case material
Case & base material
ABS resinNonflammable
Window materialPMMAUnit electrostatic process
Bezel materialABS resinNonflammable
Meter weight
DC A1mA Approx 160g Approx 115g
AC AAV E
Approx 160g(DN96A20,21)
Approx 115g
Approx 220g(DN96A22,23)
AC A (I/V) Approx 155g Approx 115g
WATT3Φ3W Approx 320g Approx 115g
(TRD BOX 460g)
VAR3Φ3W Approx 320g Approx 115g
(TRD BOX 460g)
P. F. 3Φ3W Approx 320g Approx 115g
(TRD BOX 460g)
FRQ.
Approx 172g(DN96A80,81)
Approx 125g
Approx 220g(DN96A82,83)
Standard Specifications
8
Catalog Numbers
DN□□A□□-□□□---□□/□□□
SHAPE & DIMENSION
DN96 96X96
DN72 72X72
TYPE CODE
10 T/B type DC Ammeter, Voltmeters
11 P/J type DC Ammeter, Voltmeters
20 T/B type rectifying AC Ammeters, Voltmeters
21 P/J type rectifying AC Ammeters, Voltmeters
22 T/B type rectifying AC Voltmeters(Double pointer,Only DN96)
23 P/J type rectifying AC Voltmeters(Double pointer,Only DN96)
31 I/V type AC Ammeters, Voltmeters (P/J type only)
51 Watt Meters 1P2W T/B type
52 Watt Meters 1P3W
54 Watt Meters 3P4W BAL
55 Watt Meters 3P3W UNBAL
56 Watt Meters 3P4W UNBAL
61 Var Meters 1P2W
63 Var Meters 3P3W BAL
64 Var Meters 3P4W BAL
65 Var Meters 3P3W UNBAL
66 Var Meters 3P4W UNBAL
71 Power Factor Meter 1P2W
73 Power Factor Meter 3P3W BAL
75 Power Factor Meter 3P3W UNBAL
76 Power Factor Meter 3P4W UNBAL
80 Frequency Meters (T/B type
81 Frequency Meters (P/J type)
82 Frequency Meters (T/B type) (Double pointer,Only DN96)
83 Frequency Meters (P/J type) (Double pointer,Only DN96)
INPUT CODE
□□□ See rating input code table
RATED FREQUENCY
N DC & rectifying AC(40~2kHz),
I/V type AC(50/60Hz)
A 50Hz Var & Power Factor
B 60Hz Var & Power Factor
C 400Hz I/V type AC
POINTER
L Spear type (black)
WINDOW & BEZEL
BL Clear (black)
BS Set pointer (red).Double pointer meter has
no set pointer.
OPTIONAL INPUT CODE
□□□ See rating input code table
Catalog Numbers 9
DC Ammeters
Product line-up
Model Descriptions
Taut band Pivot & jewel Dimensions
(Width × Height)
Operating
principle
Accuracy
class
DN96A10 DN96A11 96 × 96 Moving
coil type 1.5
DN72A10 DN72A11 72 × 72
Standard descriptions
Name Suffix
codes
Available
range
Internal resistance, Voltage drop,
Current consumption Notes
Taut band Pivot & jewel
DC
Ammeters
Self-contained
-ABZ 010μA 5900 Suspension type is
taut band
-ACJ 025μA 3700
-ACY 050μA 2000 6000
-ADR 0100μA 484 1950
-ADX 0150μA 1315 3310
-AEA 0200μA 121 980
-AEG 030A 680 1670
-AEM 0500μA 40 226
-AEU 0750μA 132 407
-AFA 01mA 10.5 42.4
-AFD 01.5mA 33.1 66
-AFG 02mA 7.2 22.4
-AFN 03mA 16.4 29.6
-AFX 05mA
50mV
-AGN 07.5mA
-AGZ 010mA
-AHC 015mA
-AHF 020mA
-AHM 030mA
-AHY 050mA
-AJG 075mA
-AJR 0100mA
-AJX 0150mA
-AKA 0200mA
-AKG 0300mA
-AKM 0500mA
-AKU 0750mA
-ALA 01A
-ALC 01.5A
-ALE 02A
-ALJ 03A
-ALS 05A
-AMF 07.5A
-AMT 010A
-AND 015A
-ANG 020A
-ANL 030A
For external shunt
1,3
-A01 050mV 24.8 12.5
-A04 060mV 61.5 15.3
-A05 0100mV 101.5 24.3
-A07 075mV
Meter with VR -A06 050mV 2
DC Ammeters
Specify the following information from when ordering
Code: Ex. DN96A10 AFA N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 1mA)
O
p
tional feature: If necessar
y,
s
p
ecif
y
o
p
tional feature.
10
Standard descriptions
Name Suffix
codes
Available
range
Internal resistance, Voltage drop,
Current consumption Notes
Taut band Pivot & jewel
DC
Ammeters
Zero-center meter -DAX ±5μA 5900Ω Suspension type is
taut band
-DCJ ±25μA 2000Ω 6000Ω
-DCY ±50μA 484Ω 1950Ω
-DDH ±75μA 1315Ω 3310Ω
-DDR ±100μA 121Ω 980Ω
-DDX ±150μA 680Ω 1670Ω
-DED ±250μA 40Ω 226Ω
-DEM ±500μA 10.5Ω 42.4Ω
-DEU ±750μA 33.1Ω 66Ω
-DFA ±1mA 7.2Ω 22.4Ω
-DFD ±1.5mA 16.4Ω 29.6Ω
-DFK ±2.5mA
±25mV
-DFX ±5mA
-DGN ±7.5mA
-DGZ ±10mA
-DHC ±15mA
-DHJ ±25mA
-DHY ±50mA
-DJG ±75mA
-DJR ±100mA
-DJX ±150mA
-DKD ±250mA
-DKM ±500mA
-DKU ±750mA
-DLA ±1A
-DLC ±1.5A
-DLG ±2.5A
-DLS ±5A
-DMF ±7.5A
-DMT ±10A
-DND ±15A
For external shunt
1,3 -D01 ±50mV 101.5Ω 24.3Ω
Designation of frequency used -N Always “-N”
Pointer type -L Lance type (black color)
Cover
type
Standard type -BL Clear
With set pointer (red) -BS Clear
Note: 1 The 50mV, 60mV, 75mV, 100mV and ±50mV instruments are not provided with any shunt lead.
Use any lead wire of which resistance is less than 0.05Ω in total. External shunts are not supplied.
2 For 50mV instrument with VR, current consumption is 1mA and shunt lead’s resistance compensates 2 to 0Ω.
3 An external shunt is not supplied.
11
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/011 Shunt leads resistance
/012 Designation of Internal Resistance
/013 Class up Used in DN72A10,11
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/022 Vibration proof Used in DN72A10,DN96A10
/CJ Pass the attestation used in ship (IP42)
12
Product line-up
Model Descriptions
Taut band Pivot & jewel Dimensions
(Width × Height)
Operating
principle
Accuracy
class
DN96A10 DN96A11 96 × 96 Moving
coil type 1.5
DN72A10 DN72A11 72 × 72
Standard descriptions
Name Suffix
codes Available range
Internal resistance, Voltage
drop, Current consumption Notes
Taut band Pivot & jewel
DC
Voltmeters
Self-contained
-VKM 00.5V
1mA
-VLA 01V
-VLC 01.5V
-VLE 02V
-VLJ 03V
-VLS 05V
-VMF 07.5V
-VMT 010V
-VND 015V
-VNG 020V
-VNL 030V
-VNT 050V
-VPB 075V
-VPK 0100V
-VPZ 0150V
-VRL 0200V
-VRX 0300V
-VSD 0450V
-VSF 0500V
-VSJ 0600V
For external multiplier3 -V01 01mA 10.5Ω 42.4Ω
Specified loss current for
direct instrument
-V04
1
V/50μA
-V05 V/100μA
-V08 V/500μA
Meter with VR -V11 0(1300)V2 V/1mA
Notes: 1 Specify from the above-mentioned rating between 0.5V and 300V.
2 ±20% Variable.
3 An external multiplier is not supplied
DC Voltmeters
Specify the following information from when ordering
Code: Ex. DN96A10 VNT N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 50V)
Optional feature: If necessary, specify optional feature.
Range: For suffix V04, V05, V08, V11, specify rating.
13
Standard descriptions
Name Suffix
codes
Available
range
Internal resistance, Voltage
drop, Current consumption Notes
Taut band Pivot & jewel
DC
Ammeters
Zero-center meter
-EKD ±0.25V
0.5mA
-EKM ±0.5V
-EKU ±0.75V
-ELA ±1V
-ELC ±1.5V
-ELG ±2.5V
-ELS ±5V
-EMF ±7.5V
-EMT ±10V
-END ±15V
-ENJ ±25V
-ENT ±50V
-EPB ±75V
-EPK ±100V
-EPZ ±150V
-ERS ±250V
-ERX ±300V
For external multiplier3 -E01 ±1mA 7.2Ω 22.4Ω
Designation of frequency used -N Always “-N”
Pointer type -L Lance type (black color)
Cover
type
Standard type -BL Clear
With set pointer (red) -BS Clear
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/011 Shunt leads resistance
/012 Designation of Internal Resistance
/013 Class up Used in DN72A10,11
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/022 Vibration proof Used in DN72A10,DN96A10
/CJ Pass the attestation used in ship (IP42)
14
Suppressed Meters
Product line-up
Model Descriptions
Taut band Pivot & jewel Dimensions
(Width × Height)
Operating
principle
Accuracy
class
DN96A10 DN96A11 96 × 96 Moving
coil type 1.5
DN72A10 DN72A11 72 × 72
Standard descriptions
Name Suffix
codes
Available
range
Internal resistance, Voltage
drop, Current consumption Notes
Taut band Pivot & jewel
Suppressed
meters
DC Ammeters
-AHE 4~20mA 3.1 3
-AHX 10~50mA 1.2 2.4
-A11 0.21mA 125
-A12 1~5mA 12.2
-A13 2~10mA 6.2
DC Voltmeters -VLR 1~5V 3.9
Designation of frequency used -N Always “-N”
Pointer type -L Lance type (black color)
Cover type Standard type -BL Clear
With set pointer (red) -BS Clear
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/010 AC symbol mark
/013 Class up Used in DN72A10,11
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/022 Vibration proof Used in DN72A10,DN96A10
/CJ Pass the attestation used in ship (IP42)
Suppressed Meters (DC Ammeters & Voltmeters)
Specify following information from when ordering
Code: Ex. DN96A10 AHE N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 750)
Optional feature: If necessary, specify optional feature.
15
AC Ammeters (Mean Rectifier Type)
Product line-up
Model Descriptions
Taut band Pivot & jewel Dimensions
(Width × Height)
Operating
principle
Accuracy
class
DN96A20 DN96A21 96 × 96 Mean rectifier
type 1.5
DN72A20 DN72A21 72 × 72
Standard descriptions
Name Suffix
codes
Available
range
Internal resistance, Voltage
drop, Current consumption Notes
Taut band Pivot & jewel
AC
Ammeters
Self-contained
-AEA 0~200μA 2536 3380
-AEM 0~500μA 1286 1470
-AFA 0~1mA 774 797
-AFG 0~2mA 508 507
-AFX 0~5mA 285 292
-AGZ 0~10mA 207 181
-AHF 0~20mA 118 94
For external CT1 -A40 0~10mA1 207 181
Designation of frequency used -N Always “-N” (40Hz to 2kHz)
Pointer type -L Lance type (black color)
Cover type Standard type -BL Clear
With set pointer (red) -BS Clear
Notes: 1 An external CT is not supplied. If necessary, externally connect a CT(224800).
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/013 Class up
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/022 Vibration proof Used in DN72A20,DN96A20
/CJ Pass the attestation used in ship (IP42)
AC Ammeters (Mean Rectifier Type)
Specify following information from when ordering
Code: Ex. DN96A20 AEA N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 200μA)
Optional feature: If necessary, specify optional feature.
CT ratio: If necessary, specify CT ratio.
16
Product line-up
Type
Model Descriptions
Taut band Pivot & jewel Dimensions
(Width × Height)
Operating
principle
Accuracy
class
DN96A20 DN96A21 96 × 96 Mean rectifier
type 1.5
Double pointer DN96A22 DN96A23
DN72A20 DN72A21 72 × 72
Standard descriptions
Name Suffix codes Available range Internal resistance Notes
Taut band Pivot & jewel
AC
Voltmeter
Self-contained
-VLJ 0~3V 3kΩ 2.8 kΩ
-VLS 0~5V 5 kΩ 4.7 kΩ
-VMT 0~10V 9.8 kΩ 9.6 kΩ
-VND 0~15V 15 kΩ 14.8 kΩ
-VNL 0~30V 30 kΩ 29.8 kΩ
-VNT 0~50V 48.5 kΩ
-VPB 0~75V 75 Ω
-VPK 0~100V 101.6 kΩ
-VPZ 0~150V 151.6 kΩ
-VRL 0~200V 201.6 kΩ
-VRX 0~300V 301.6 kΩ
For external multiplier
-V01 0~1mA 774 Ω 797 kΩ
For external VT3
-V12 0~150V 151.6 kΩ
-V51 0~275V 271.6 kΩ
-V52 0~289.5V 301.6 kΩ
-V53 0~293.3V
Specified loss current
for direct instrument
-V06 1 V/200
μA
-V08 V/500
μA
Meter with VR -V11 03V, 05V,, V/1m
Designation of frequency used -N Always “-N” (40Hz to 2kHz)
Pointer type -L Lance type (black color)
Cover
type
Standard type -BL Clear
With set pointer (red) -BS Clear
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/013 Class up
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/022 Vibration proof Used in DN72A20,DN96A20
/CJ Pass the attestation used in ship (IP42)
AC Voltmeters (Mean Rectifier Type)
Specify following information from when ordering
Code: Ex. DN96A20 VRX N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 300V)
Range: For suffix code V06, V08, V11, specify rating.
Optional feature: If necessary, specify optional feature.
CT ratio: If necessary, specify CT ratio.
17
AC Ammeters (Moving Iron Type)
Product line-up
Model Descriptions
Pivot & jewel Dimensions
(Width × Height) Operating principle Accuracy
class
DN96A31 96 × 96
Mean rectifier type 1.5
DN72A31 72 × 72
Standard descriptions
Name Suffix codes Available range Power consumption VA Notes
AC
Voltmeters
-AHY 0~50mA 0.4
-AJR 0~100mA 0.4
-AJX 0~150mA 0.3
-AKG 0~300mA 0.4
-AKM 0~500mA 0.4
-ALA 0~1A 0.4
-ALC 0~1.5A 0.3
-ALE 0~2A 0.4
-ALJ 0~3A 0.4
-ALS 0~5A 0.5
-AMF 0~7.5A 0.4
-AMT 0~10A 0.4
-AND 0~15A 0.6
-ANG 0~20A 0.7
-ANL 0~30A 0.6
Two-fold extended
-A21 00.51A 0.4
-A22 012A 0.4
-A23 0~2~4A 0.4
-A24 03~6A 0.4
-A25 05~10A 0.5
-A26 01020A 0.4
-A27 0~15~30A 0.6
-A28 020~40A 0.7
-A29 030~60A 0.6
Three-fold extended
-A32 013A 0.4
-A33 0~2~6A 0.4
-A34 03~9A 0.4
-A35 05~15A 0.5
-A36 01030A 0.4
-A37 0~15~45A 0.6
-A38 020~60A 0.7
For external CT1 -A41 01A 0.4
-A42 05A 0.5
Two-fold extended
(For external CT1)
-A43 012A 0.4
-A44 05~10A 0.5
Three-fold extended
(For external CT1)
-A45 013A 0.4
-A46 05~15A 0.5
AC Ammeters (Moving Iron Type)
Specify following information from when ordering
Code: Ex. DN96A31 A42 N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 300A)
Optional feature: If necessary, specify optional feature.
CT ratio: If necessary, specify CT ratio. (Ex. 300/5A)
18
Standard descriptions
Name Suffix codes Available range Notes
Current
Designation of frequency used -N 50/60Hz
-C 400Hz
Pointer type -L Lance type (black color)
Cover type -BL Clear Clear
-BS Clear Clear
Note: 1 An external CT is not supplied.
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/013 Class up Used in DN72A30
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/CJ Pass the attestation used in ship (IP42)
19
Product line-up
Model Descriptions
Pivot & jewel Dimensions
(Width × Height) Operating principle Accuracy
class
DN96A31 96 × 96 Mean rectifier type 1.5
DN72A31 72 × 72
Standard descriptions
Name Suffix codes Available range Power consumption VA Notes
AC
Ammeters
Self-contained
-VMT 010V 1.6
-VND 015V 1.2
-VNG 020V 1.7
-VNL 030V 1.5
-VNT 050V 1.6
-VPB 075V 1.3
-VPK 0100V 1.6
-VPZ 0150V 1.4
-VRL 0200V 1.3
-VRS 0250V 1.6
-VRX 0300V 1.4
-VSD 0450V
-VSF 0500V 1.8
-VSJ 0~600V 2.2
-V14 0~150/ 3V 1.5
For external VT1 -V12 0150V 1.4
Designation of frequency used -N 50/60Hz
-C 400Hz
Pointer type -L Lance type (black color)
Cover
type
Standard type -BL Clear
With set pointer (red) -BS Clear
Note: 1 An external multiplier and VT are not supplied.
AC Voltmeters (Moving Iron Type)
Specify following information from when ordering
Code: Ex. DN96A30 VRX N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 300V)
Optional feature: If necessary, specify optional feature.
CT ratio: If necessar
y,
s
p
ecif
y
VT ratio.
20
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/013 Class up Used in DN72A30
/015 Triple set of numbers - Double set of divisions
/016 Triple set of numbers - Triple set of divisions
/018 Except Yokogawa standard scale divisions
/CJ Pass the attestation used in ship (IP42)
21
Product line-up
Type
Model Descriptions
Taut band Pivot & jewel Dimensions
(Width × Height)
Operating
principle Accuracy class
DN96A80 DN96A81
96 × 96 Differential
type 0.5 or 1.0 Double pointer DN96A82 DN96A83
DN72A80 DN72A81 72 × 72
Standard descriptions
Name Suffix
codes Available range Available
range
Power
consumption
VA
Operating
range Notes
Frequency meters
-H30 4555Hz
100V
0.5
0.4 80130V
-H31 5565Hz 0.5
-H32 4565Hz 1.0
-H10 4555Hz
110V
0.5
-H11 5565Hz 0.5
-H12 4565Hz 1.0
-H40 4555Hz
115V
0.5
-H41 5565Hz 0.5
-H42 4565Hz 1.0
-H50 4555Hz
200V
0.5
0.8 160260V
-H51 5565Hz 0.5
-H52 4565Hz 1.0
-H20 4555Hz
220V
0.5
-H21 5565Hz 0.5
-H22 4565Hz 1.0
-H60 4555Hz
230V
0.5
-H61 5565Hz 0.5
-H62 4565Hz 1.0
Designation of frequency
used -N 50/60Hz
Pointer type -L Lance type (black color)
Cover
type
Standard type -BL Clear
With set pointer
(red) -BS Clear
Optional feature
Code Feature Notes
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/022 Vibration proof Used in DN72A80,DN96A80
/CJ Pass the attestation used in ship (IP42)
Fr equency Meters
Specify following information from when ordering
Code: Ex. DN96A80 H11 N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Optional feature: If necessary, specify optional feature.
22
Specify following information from when ordering
Code: Ex. DN96A55 W14 N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 120kW)
Calibration watts: In case of using external CT and/of VT, calculate the possible
full scale from the follow page and be sure that is within the range shown
above. (Ex. 750W)
Optional feature: If necessary, specify optional feature.
VT ratio: If necessary, specify VT ratio. (Ex. 440/110V)
Product line-up
Model (Taut band) Dimensions
(Width×Height)
Operating
principle
Accuracy
class Transducer
1P2W 1P3W 3P3W 3P4W
Unbal Bal. Unbal.
DN96A51 DN96A52 DN96A55 DN96A54 DN96A56 96×96 Feedback
time division
multiplier type
1.5
Self contained
DN72A51 DN72A52 DN72A55 DN72A54 DN72A56 72×72 External box
Standard descriptions
Name Suffix codes Available range Notes
Current Voltage
Wattmeters
-W71 0.1A
100V
-W72 0.5A
-W51 1A
-W52 5A
-W01 0.1A
110/ 3V
-W02 0.5A
-W11 1A
-W12 5A
-W03 0.1A
110V
-W04 0.5A
-W13 1A
-W14 5A
-W73 0.1A
115V
-W74 0.5A
-W53 1A
-W54 5A
-W75 0.1A
120V
-W76 0.5A
-W55 1A
-W56 5A
-W81 0.1A
200V
-W82 0.5A
-W61 1A
-W62 5A
-W05 0.1A
220V
-W06 0.5A
-W15 1A
-W16 5A
-W83 0.1A
230V
-W84 0.5A
-W63 1A
-W64 5A
-W85 0.1A
240V
-W86 0.5A
-W65 1A
-W66 5A
Wattmeters 23
Standard descriptions
Name Suffix codes Available range Notes
Current
Designation of frequency used -N 50/60Hz
Pointer type -L Lance type (black color)
Cover type -BL Clear Clear
-BS Clear Clear
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/CJ Pass the attestation used in ship (IP42)
Available standard calibration watts
Rating
Single phase
2-wire
Single phase
3-wire 3-phase 3-wire 3-phase 4-wire
Voltage Current
DN96A51 DN96A52 DN96A55 DN96A54/56
DN72A51 DN72A52 DN72A55 DN72A54/56
110/ 3V 1A 32 to 95W 95 to 285W
5A 160 to 475W 475 to 1400W
110V, 115V, 120V 1A 55 to 164W 95 to 285W 95 to 285W 218 to 495W
5A 275 to 820W 475 to 1400W 475 to 1400W 1090 to 2475W
220/ 3V 1A 250 to 570W
5A 1250 to 2850W
200V, 220V, 240V 1A 110 to 328W 250 to 570W 250 to 570W 430 to 990W
5A 550 to 1640W 1250 to 2850W 1250 to 2850W 2150 to 4950W
(1) When using VT and/or CT, calibration watts will be as follows;
Connection Full scale
value VT ratio CT ratio Calibration watts
EX.1 3-phase
3-wire 20kW 440/110V
30/5A
EX.2 Single
phase 2-wire 7.5kW 660/110V 20/5A
(2) Calibration watts are 65 to 150%. Standard watts beyond the limits are not available.
Single phase 2-wire: Standard watts = Voltage rating × Current rating
3-phase 3-wire: Standard watts = 3 × Line voltage rating × Current rating
3-phase 4-wire: Standard watts = 3 × Phase voltage rating × Current rating
Model
Calibration watts = MA
X
. Full scale value
VT ratio × CT ratio
FS= =833.3W Available
20kW
440/110×30/5
FS= =833.3W Special order with TOKUCHU sheet
7.5kW
660/110×20/5
24
Product line-up
Model (Taut band) Dimensions
(Width×Height)
Operating
principle
Accuracy
class Transducer
1P2W 3P3W 3P4W
Bal. Unbal Bal. Unbal
DN96A61 DN96A63 DN96A65 DN96A64 Self
contained 96×96 Feedback
time division
multiplier type
1.5
Self contained
DN72A61 DN72A63 DN72A65 DN72A64 External
box 72×72 External box
Standard descriptions
Name Suffix codes Available range Notes
Current Voltage
Varmeters -M71 0.1A
100V
-M72 0.5A
-M51 1A
-M52 5A
-M01 0.1A
110/ 3V
-M02 0.5A
-M11 1A
-M12 5A
-M03 0.1A
110V
-M04 0.5A
-M13 1A
-M14 5A
-M73 0.1A
115V
-M74 0.5A
-M53 1A
-M54 5A
-M75 0.1A
120V
-M76 0.5A
-M55 1A
-M56 5A
-M81 0.1A
200V
-M82 0.5A
-M61 1A
-M62 5A
-M05 0.1A
220V
-M06 0.5A
-M15 1A
-M16 5A
-M83 0.1A
230V
-M84 0.5A
-M63 1A
-M64 5A
-M85 0.1A
240V
-M86 0.5A
-M65 1A
-M66 5A
Varmeters
Specify following information from when ordering
Code: Ex. DN96A65 – M14 – N – L – BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Scale and unit: Specify full scale value and unit. (Ex. 0 to 10kvar)
Calibration watts: In case of using external CT and/of VT, calculate the possible
full scale from the follow page and be sure that is within the range
shown above. (Ex. 416.6 var)
Optional feature: If necessary, specify optional feature.
VT ratio: If necessary, specify VT ratio. (Ex. 660/110V)
CT ratio: If necessary, specify CT ratio. (Ex. 20/5V)
25
Standard descriptions
Name Suffix codes Available range Notes
Current
Designation of frequency used
-N 50/60Hz For DN□□A63, DN□□A64
-A 50Hz For DN□□A61, DN□□A65,
DN□□A66.
-B 60Hz
Pointer type -L Lance type (black color)
Cover type Standard type Clear Clear
With set pointer (red) Clear Clear
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/009 Polarity change marking (LAG to LEAD)
/CJ Pass the attestation used in ship (IP42)
Available standard calibration vars(Zero-center meter)
Rating
Single phase 2-wire 3-phase 3-wire
(Unbalanced)
3-phase 3-wire(Balanced)
3-phase 4-wire(Balanced)
3-phase 4-wire
(Unbalanced)
Voltage Current DN96A51 DN96A55 DN96A53/54 DN96A56
DN72A51 DN72A55 DN72A53/54 DN72A56
110/ 3V 1A 21 to 95 var
5A 105 to 475 var
110V, 115V, 120V 1A 36 to 164 var 95 to 285 var 62 to 285 var 190 to 570 var
5A 180 to 820 var 475 to 1400 var 312 to 1400 var 950 to 2850 var
220/ 3V 1A
5A
200V, 220V, 240V 1A 72 to 328 var 190 to 570 var 125 to 570 var
5A 360 to 1640 var 950 to 2850 var 625 to 2850 var
(1) When using VT and/or CT, calibration vars will be as follows;
Connection Full scale
value VT ratio CT ratio
Calibration vars
EX.1 3-phase 3-wire
(Balanced) 10kvar 660/110V
30/5A
EX.2 3-phase 2-wire
(Unbalanced) 7.5kvar 660/110V 20/5A
(2) Calibration vars are 33 to 150%. Standard vars beyond the limits are not available.
Single phase 2-wire: Standard vars = Voltage rating × Current rating
3-phase 3-wire: Standard vars = 3 × Line voltage rating × Current rating
3-phase 4-wire: Standard vars = 3 × Phase voltage rating × Current rating
Model
Calibration vars = MA
X
. Full scale value
VT ratio × CT ratio
FS= =312.5 var Special order
7.5kva
r
660/110×20/5
FS= =416.6 var Available
10kva
r
660/110×30/5
26
Power Fa
Product line-up
Model (Taut band) Dimensions
(Width×Height) Operating principle Accuracy
class Transducer
1P2W 3P3W 3P4W
Bal. Unbal Unbal.
DN96A71 DN96A73 DN96A75 DN96A76 Self contained
Phase defection type
For single-phase and
3-phase(balanced)
Feedback time division
multiplier type
For 3-phase(unbalanced)
5.0
Self contained
DN72A71 DN72A73 DN72A75 DN72A76 External box External box
Standard descriptions
Name Suffix codes Available range Notes
Current Voltage
Power
factor
meters
Single phase 2-wire
3-phase 3-wire
-C71 0.1A
100V
For:
DN96A71/73/75,
DN72A71/73/75
Standard scale:
LEAD 0.50.5 LAG
-C72 0.5A
-C51 1A
-C52 5A
-C01 0.1A
110V
-C02 0.5A
-C13 1A
-C14 5A
-C73 0.1A
115V
-C74 0.5A
-C53 1A
-C54 5A
-C75 0.1A
120V
-C76 0.5A
-C55 1A
-C56 5A
-C81 0.1A
200V
-C82 0.5A
-C61 1A
-C62 5A
-C03 0.1A
220V
-C04 0.5A
-C15 1A
-C16 5A
-C83 0.1A
230V
-C84 0.5A
-C63 1A
-C64 5A
-C85 0.1A
240V
-C86 0.5A
-C65 1A
-C66 5A
3-phase 4-wire
-C07 0.1A
110/ 3V
For:
DN96A76,
DN72A76
-C08 0.5A
-C11 1A
-C12 5A
(Continued to next page)
Power Factor Meters
Specify following information from when ordering
Code: Ex. DN96A75 C14 N L BL / □□□
Model Suffix
Code
Always
“N”
Pointer Cover color
&
set pointer
Optional
ft
Optional feature: If necessary, specify optional feature.
VT ratio: If necessary, specify VT ratio. (Ex. 660/110V)
CT ratio: If necessary, specify CT ratio. (Ex. 20/5V)
27
Standard descriptions
Name Suffix codes Available range Notes
Current
Designation of frequency used
-N 50/60Hz For DN□□A73, DN□□A74
-A 50Hz For DN□□A71, DN□□A75,
DN□□A76.
-B 60Hz
Pointer type -L Lance type (black color)
Cover type Standard type Clear Clear
With set pointer (red) Clear Clear
Optional feature
Code Feature Notes
/003 Single-Division, Double-marking
/004 Double-Divisions, Double-marking
/005 Color line (Red, Green, Yellow, Blue)
/006 Color band (Red, Green, Yellow, Blue)
/007 Color marking (Red, Green, Yellow, Blue)
/008 Meter mounting position
/009 Polarity change marking (LAG to LEAD)
/CJ Pass the attestation used in ship (IP42)
Standard rating
Rating Usable
Voltage Current Voltage Current
110/ 3V 1A 52 to 75 V 0.3 to 1.2 A
5A 1.5 to 6 A
110V 1A 90 to 130 V 0.3 to 1.2 A
5A 1.5 to 6 A
220/ 3V 1A 104 to 150 V 0.3 to 1.2 A
5A 1.5 to 6 A
220V 1A 180 to 260 V 0.3 to 1.2 A
5A 1.5 to 6 A
28
95.6
95.6
5.1 43.5 15.7 92±0.5
92±0.5
71.7
71.7
5.1 43.5 15.7 68±0.5
68±0.5
140
40
O
6
.
5
6
160
98
O
98.5
92±0.5
92±0.5
95.6
95.6
5.1 66.6 16.5
DN96 series
DN96A10,11
DN96A20,21,
DN96A22,23
DN96A31
DN96A80,81,
DN96A82,83
DN96A5
DN96A6
DN96A7
DN72 series
DN72A10,11
DN72A20,21
DN72A31
DN72A80,81
External
transducer:
DN72A5
DN72A6
DN72A7
26
Dimensions and Panel Mountings 29
DC Ammeters, Voltmeters
AC Ammeters, Voltmeters
Wattmeters
Connection Diagrams
<With external shunt, multiplier> <With high-tension multiplier>
DN96A10,11
DN72A10,11
DN96A20,21
DN72A20,21
DN96A31
DN72A31
<With CT, VT>
Single phase 2-wire
DN96A51 DN72A51
DN96A22,23
30
Varmeters
3-phase 3-wire
(Unbalanced)
DN96A55 DN72A55
3-phase 4-wire
(Balanced)
DN96A54 DN72A54
3-phase 4-wire
(Unbalanced)
DN96A56 DN72A56
Single phase 2-wire
DN96A61 DN72A61
31
3-phase 3-wire
(Balanced)
DN96A63 DN72A63
3-phase 3-wire
(Unalanced)
DN96A65
DN72A65
DN96A64
3-phase 4-wire
(Balanced)
DN72A64
3-phase 4-wire
(Unbalanced)
DN96A66 DN72A66
32
Power factor meters
DN96A71
Single phase 2-wire
DN72A71
33
3-phase 3-wire
(Balanced)
DN96A73 DN72A73
3-phase 3-wire
(
Unbalanced
)
DN96A75
DN72A75
3-phase 4-wire
(
Unbalanced
)
DN96A76 DN72A76
Frequency meters
DN96A80,81
DN72A80,81
34
DN96A82,83
E-mail: meters-instr@us.yokogawa.com
2 Dart Road
Newnan, Georgia 30265
Phone: 800-888-6400
Represented by: