KBU8005 THRU KBU810
1 / 4
Yangzhou Yangjie Electronic Technology Co., Ltd.
S-C065
Rev.2.3, 13-Aug-19
www.21yangjie.com
Bridge Rectifiers
Features
UL recognition, file #E230084
● Ideal for printed circuit boards
● High surge current capability
● Solder dip 275 °C max. 7 s, per JESD 22-B106
Typical Applications
General purpose use in AC/DC bridge full wave rectification
for switching power supply, home appliances, office
equipment, industrial automation applications.
Mechanical Data
Package: KBU
Molding compound meets UL 94 V-0 flammability
rating, RoHS-compliant
Terminals: Tin plated leads, solderable per
J-STD-002 and JESD22-B102
Polarity: As marked on body
Maximum Ratings (Ta=25 Unless otherwise specified
PARAMETER SYMBOL UNIT KBU8005 KBU801 KBU802 KBU804KBU806KBU808 KBU810
Device marking code KBU8005 KBU801 KBU802 KBU804KBU806KBU808 KBU810
Repetitive Peak Reverse Voltage VRRM V 50 100 200 400 600 800 1000
Average Rectified Output
Current @60Hz sine wave,
R-load
With heatsink
Tc =115 IO A
8
Without heatsink
Ta =25 2.8
Surge(Non-repetitive)Forward Current @60Hz
half-sine wave, 1 cycle, Ta=25 IFSM A 150
Current Squared Time @1ms≤t≤8.3ms
Tj=25,Rating of per diode I2t A2S 93
Storage Temperature Tstg -55 ~+150
Junction Temperature Tj -55 ~+150
Electrical CharacteristicsTa=25 Unless otherwise specified
PARAMETER SYMBOL UNIT TEST
CONDITIONS KBU8005 KBU801 KBU802 KBU804KBU806KBU808 KBU810
Maximum instantaneous forward
voltage drop per diode VF V IFM=4A 1.1
Maximum DC reverse current at
rated DC blocking voltage per diode IRRM μA VRM=VRRM 10
COMPLIANT
RoHS
+
~
~
‐
KBU8005 THRU KBU810
2 / 4
Yangzhou Yangjie Electronic Technology Co., Ltd.
S-C065
Rev.2.3, 13-Aug-19
www.21yangjie.com
Thermal Characteristics Ta=25 Unless otherwise specified
PARAMETER SYMBOL UNIT KBU8005 KBU801KBU802KBU804KBU806KBU808KBU810
Thermal
Resistance
Between junction and
ambient, Without
heatsink
RθJ-A
/W
28(1)
Between
junction and
case, With
heatsink
RθJ-C 4.8(2)
Notes
(1) Thermal resistance from junction to ambient with units mounted in free air ,no heat sink,P.C.B. at 0.375” (9.5mm) lead length with
0.5×0.5”(12×12mm) copper pads.
(2) Thermal resistance from junction to case with units mounted on an aluminum plate heat sink.
Ordering Information (Example)
PREFERED P/N PACKAGE CODE UNIT WEIGHT(g) MINIIMUM
PACKAGE(pcs)
INNER BOX
QUANTITY(pcs)
OUTER CARTON
QUANTITY(pcs) DELIVERY MODE
KBU8005~KBU810 A1 Approximate 7.2 400 400 2400 Paper Box
Characteristics(Typical)
`
0
Average Forward Output Current(A)
Case Tem perature()
FIG1:Io-Tc Curve
50 150
100
0
2
4
6
8
1
0
Peak Forward Surge Current (A)
2 5 10 20 50 100
Half-sine wave
0
non-repetitive
Ta=25
FIG2:Surge Forward Current Capability
Number of Cycles
75
150
225
0.4 0.6 0.8 1.0 1.2 1.4
0.1
0.2
0.5
Instantaneous Forward Voltage (V)
Instantaneous Forward Current(A)
FIG3:Instantaneous Forward Voltage
1.0
10
20
40
60
5.0
Ta=25
Instantaneous Reverse Current(μA)
0 20 40 60 80 100
0.01
0.1
1
10
100
Tj=125
Tj=25
FIG4:Typical Reverse Characteristics
Percent of Rated Peak Reverse Voltage(%)
Heatsink mounting
Tc,3.0×3.0×0.12
(7.5×7.5×0.3cm)
Al.Plate
KBU8005 THRU KBU810
3 / 4
Yangzhou Yangjie Electronic Technology Co., Ltd.
S-C065
Rev.2.3, 13-Aug-19
www.21yangjie.com
Outline Dimensions
Dimensions in millimeters
KBU
C
DIA
D
B
E
G
F
- AC +
A
8.2
3.8×5.7
HOLE THRU
KBU
Dim Min Max
A 18.8 19.8
B 20.0 /
C 1.2 1.3
D 4.6 5.6
E 6.7 7.1
F 4.6 5.0
G 22.7 23.7
KBU8005 THRU KBU810
4 / 4
Yangzhou Yangjie Electronic Technology Co., Ltd.
S-C065
Rev.2.3, 13-Aug-19
www.21yangjie.com
Disclaimer
The information presented in this document is for reference only. Yangzhou Yangjie Electronic Technology Co., Ltd. reserves the
right to make changes without notice for the specification of the products displayed herein to improve reliability, function or design
or otherwise.
The product listed herein is designed to be used with ordinary electronic equipment or devices, and not designed to be used with
equipment or devices which require high level of reliability and the malfunction of with would directly endanger human life (such as
medical instruments, transportation equipment, aerospace machinery, nuclear-reactor controllers, fuel controllers and other safety
devices), Yangjie or anyone on its behalf, assumes no responsibility or liability for any damages resulting from such improper use
of sale.
This publication supersedes & replaces all information previously supplied. For additional information, please visit our website
http:// www.21yangjie.com , or consult your nearest Yangjie’s sales office for further assistance.