1
Power entry modules with line filter EF12
www.schurter.com/pg06
Connectors
Inlet filter, front side mounting, deeply placed circuit breaker TA45 2-pole
Standard- or Medical-Filter
C20
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter EF11
Approvals
- VDE License Number: 40001520
- UL License Number: E72928
Characteristics
- All single elements are already wired
- Line switch non-illuminated
Illuminated version on request
Thermal overload protection
Optional with undervoltage release or remote trip release
- With EMC-shield
- Qualified for use in equipment according IEC/EN 60950
References
General Product Information
Weblinks
Approvals: www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
CHINA-RoHS: www.schurter.com/china-rohs
Webstore: www.schurterinc.com/estore/search.ihtml
Technical Data
Ratings IEC 12 - 16 A @ Ta 40 °C / 250 VAC; Hz 50
Ratings UL/CSA 12 - 20 A @ Ta 40 °C / 125 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Temp. -10 °C to 55 °C
Climatic Category 10/055/21 acc. to IEC 60068-1
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness s Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet C20 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
condition) pin-temperature 70 °C, 16 A,
Protection class I
Circuit breaker Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Line Switch Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical details
Line Filter Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
MTBF > 100'000 h acc. to MIL-HB-217 F