1
Power entry modules with line filter EF12
www.schurter.com/pg06
Connectors
Inlet filter, front side mounting, deeply placed circuit breaker TA45 2-pole
Standard- or Medical-Filter
C20
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Inlet Protection class I, circuit breaker type TA45 2-pole, Line filter in
standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter EF11
Approvals
- VDE License Number: 40001520
- UL License Number: E72928
Characteristics
- All single elements are already wired
- Line switch non-illuminated
Illuminated version on request
Thermal overload protection
Optional with undervoltage release or remote trip release
- With EMC-shield
- Qualified for use in equipment according IEC/EN 60950
References
General Product Information
Weblinks
Approvals: www.schurter.com/approvals
RoHS: http://www.schurter.com/rohs
CHINA-RoHS: www.schurter.com/china-rohs
Webstore: www.schurterinc.com/estore/search.ihtml
Technical Data
Ratings IEC 12 - 16 A @ Ta 40 °C / 250 VAC; Hz 50
Ratings UL/CSA 12 - 20 A @ Ta 40 °C / 125 VAC; 60 Hz
Leakage Current standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
Dielectric Strength > 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
Allowable Operation Temp. -10 °C to 55 °C
Climatic Category 10/055/21 acc. to IEC 60068-1
Degree of Protection from front side IP 40 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I acc. to IEC 61140
Terminal Quick connect terminals 6.3 x 0.8 mm
Panel Thickness s Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Material: Housing Thermoplastic, black, UL 94V-0
Appliance-Inlet /-Outlet C20 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
condition) pin-temperature 70 °C, 16 A,
Protection class I
Circuit breaker Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In 3A/240VAC : 300A
Line Switch Rocker switch 2-pole, non-illuminated
or illuminated, acc. to IEC 61058-1
Technical details
Line Filter Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
MTBF > 100'000 h acc. to MIL-HB-217 F
2
Power entry modules with line filter
EF12
www.schurter.com/pg06
Connectors
Dimensions Length 59.5 mm
3.3
90
101
6.4
33.9
59.5 5.3
12.2 40.55
79.2
10.9
32.2
37
41.210.6
76.2* 2.8
5.5
R 6.5
R 4.7
R 2.8
0.8
40.55
12.55
80.05
32.9
R 3.05
±0.10
90
±0.10
3.6
±0.05
R 3.55
±0.10
81
±0.05
4.55
S
9.5
* --- Version TA45 with undervoltage release
Technical Data of Filter-Components
Rated Current
[A]
Filter-Type Inductances
L [mH]
Capacitance
CX [nF]
Capacitance
CY [nF]
R [MW]
12 Standard Version 2 x 0.8 100 2.2 1
16 Standard Version 2 x 0.6 100 2.2 1
20 Standard Version 2 x 0.3 100 2.2 1
12 Medical Version (M5) 2 x 0.8 100 - 1
16 Medical Version (M5) 2 x 0.6 100 - 1
20 Medical Version (M5) 2 x 0.3 100 - 1
Diagrams
Standard version
1) Line
2) Load
Medical version
1) Line
2) Load
Attenuation Loss - - - - differential mode _____ common mode
Standard version
12 A 16 A 20 A
3
Power entry modules with line filter EF12
www.schurter.com/pg06
Connectors
Medical version (M5)
12 A 16 A 20 A
Packaging unit 16 Pcs
Accessory
Description
Assorted Covers
Rear Cover
Cord retaining kits
Cord retainning strain reliefe
4
Power entry modules with line filter
EF12
www.schurter.com/pg06
Connectors
/ 7 £xä ä
ÕÀÃ
-ÜÌV vÀÌ ,ViÀ
7L>V ÜÌi q
L>V L>V q
ÈL>V q À>}i ÌÀ>ë°
iLÃÃi`
«ÀÌi` ÜÌi
«ÀÌi` L>V
«ÀÌi` ÜÌi
-ÕÀv>Vi ÕÃÌÀ>Ì ÕÀ v «ÀÌ
,ViÀ i}i`
"
"
"
"
"
"
«ÀÌi` L>V
*«ÀÌi` ÜÌi
,«ÀÌi` L>V
-ÕÀv>Vi ÕÃÌÀ>Ì ÕÀ v «ÀÌ
`i
£ä]ä £ää
££]ä ££ä
£Ó]ä £Óä
`i
£Î]ä £Îä
£{]ä £{ä
£x]ä £xä
`i
£È]ä £Èä
£Ç]ä £Çä
£n]ä £nä
`i
£]ä £ä
Óä]ä Óää
7ÌÕÌ Àii>Ãi\ V`i ä
1`iÀÛÌ>}i Àii>Ãi ,iÌi ÌÀ« Àii>Ãi
1
L
1
L>
1
V
1 < `i
,>Ìi`
ÛÌ>}i 1
U U U
UUU
UUU
U
U
U
Ó
Î
{
Ó{ä 6 
ÓÎä 6 
£Óä 6 
"
"
"
*ÃÌ v Ìi ÀViÀ i}i`
i°} U 7ÌÕÌ ÌiÀ> ÛiÀ>` «ÀÌiVÌ\ V`i ää
U 7Ì ÌiÀ> ÛiÀ>` «ÀÌiVÌ\ À>Ìi` VÕÀÀiÌ ®
,>Ìi` VÕÀÀiÌ\
Pr Óä
/>Li £ -iiVÌ vÀ ÌÞ«i /{x
"À`iÀ iÝ>«i
U i ÃÜÌV
U Ó«i] ÀViÀ >VÌÕ>Ìi`
U +ÕV ViVÌ ÌiÀ>
"ÌiÀ ÌÞ«ià  ÀiµÕiÃÌ
7ÌÕÌ Õ>Ì
7Ì Õ>Ì ÓÓäoÓ{ä 6
££äo£Óä 6
Îx
>
>}À>
/iÀ> ÛiÀ>` «ÀÌiVÌ ÜÌÕÌ ÜÌ £«i ÜÌ Ó«i
 / 
äÓ £Ó ÎÓ
ä{ £{ Î{
È
Î{ Î
Èx
P
"ÌiÀ À>Ìi` VÕÀÀiÌÃ  ÀiµÕiÃÌ
5
Power entry modules with line filter EF12
www.schurter.com/pg06
Connectors
* Ambient temperature [°C] Correction factor
–10 0,89
–5 0,91
0 0,92
+23 1,00
+30 1,03
+40 1,08
+55 1,16
Technical data (continued)
Circuit breaker
Tripping characteristics
In< 3 A
Tripping characteristics
In*3… < 18 A
Tripping characteristics
In*18 A
Type TA45
Rated current In <3 A
1 pole protected
2 pole protected
Ambient temp. +23 °C
10'000
60
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In]
10854321,32
Tripping time
Type TA4 5
Rated current In 3 A... < 18 A
1 pole protected
2 pole protected
Ambient temp. +23 °C
10'000
60
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ][ min ]
10
5
1
30
20
1,05
Multiple of rated current [ x In]
10854321,32
Tripping time
Type TA4 5
Rated current In18 A
1 pole protected
2 pole protected
Ambient temp. +23 °C
Tripping time
10'000
0
2`000
1`000
500
200
100
50
20
10
5
2
1
0,5
0,3
0,2
0,1
[ sec ]min ]
0
5
1
0
0
1,05
Multiple of rated current [ x In]
10854321,32
1) Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 °C. To de-
termine the rated current for a lower or higher ambient temperature,
use a correction factor from the table on the right side:
1) Example
Rated current at +23 °C 6,0 A
Ambient temperature +40 °C
Correction factor 1,08
Chosen rated current at
+40 °C ambient temperature 6 A x 1,08 = 6,5 A
* Temperature must be measured at the rear of the breaker next to
the terminals after equipment operating temperature has been
reached.
Order code for EF12 (order example)
Type Order code TA45
(2-pole rocker-switch
without accessories)
EF12. A B T W F 1 5 0 C 0 .
see table 1
11 1 0. 01
Wiring
1= wired
Protection class
0= Class I, housing black
Panel mount
0= Screw-on version
Terminals
1= Quick connect terminals 6,3 x 0,8 mm
Line filter version
1= standard
2= medical
Line filter, rated current
1= 20 A, 2= 16 A, 3= 12 A
Please note that Schurter will establish an internal new part number
for logistical use in addition to the order code. The format of this in-
ternal part number is, for example EF12.xxxx.1110.01
Application note
The rated current of the line filter must be equal or higher than the
rated current of the circuit-breaker
Other versions on request
Rocker switch illuminated
The specifications, descriptions and illustrations indicated in this document are based on
current information. All content is subject to modifications anamendments.