www.recom-power.com REV.: 5/2019 ECO-1
RK/H6 & RH/H6
DC/DC Converter
1 Watt
SIP7
Single and Dual
Output
UL60950-1 certified
CAN/CSA C22.2 No. 60950-1-07 certified
UL62368-1 certified
CAN/CSA C22.2 No. 62368-1-14 certified
IEC/EN60950-1 certified
IEC/EN62368-1 certified
CB report
E224736
Features
Unregulated
Converters
• High 6.4kVDC/1s isolation
• Wide operating temperature range from
-40°C to +90°C without derating
• High capacitive load capability
• Continuous short circuit protection
• Efficiency up to 80%
Description
The RK/H6 and RH/H6 series 1W DC/DC converters feature high 6.4kVDC isolation and an extended
operating temperature range up to +90°C without derating, yet are lower cost than standard high
isolation converters. They are suitable for demanding industrial and high isolation test and measurement
applications.
Selection Guide
Part nom. Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ. Load (1)
[VDC] [VDC] [mA] [%] [µF]
RK-xx3.3S/H6 5, 12, 15, 24 3.3 303 71-74 1000
RK-xx05S/H6 5, 12, 15, 24 5 200 74-77 1000
RK-xx12S/H6 5, 12, 15, 24 12 84 77-79 220
RK-xx15S/H6 5, 12, 15, 24 15 66 77-80 220
RH-xx3.3D/H6 5, 12, 15, 24 ±3.3 ±152 73-74 ±330
RH-xx05D/H6 5, 12, 15, 24 ±5 ±100 74-77 ±330
RH-xx12D/H6 5, 12, 15, 24 ±12 ±42 77-80 ±100
RH-xx15D/H6 5, 12, 15, 24 ±15 ±33 78-80 ±100
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load
Notes:
Note2: add suffix „K“ for Single output or suffix „H“ for Dual output
Model Numbering
Ordering Examples:
RK-123.3S/H6 = 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output, 6.4kVDC/1s isolation
RH-0505D/H6 = 5VDC Input Voltage, 5VDC Output Voltage, Dual Output, 6.4kVDC/1s isolation
6.4kVDC isolation
Single
6.4kVDC isolation
Dual
Input Voltage
Output Voltage
Input Voltage
Output Voltage
RK- __ __ S/H6
RH- __ __ D/H6