(a) Series Name FBR6: FBR600 Series
(b) Number of Contacts 1 : 1 pole
2 : 2 poles
(c) Contact Arrangement 1 : Form C
3 : Form A
5 : Form B
(d) Enclosure Nil : Flux free type
N : Plastic sealed type
(e) Nominal Voltage (Example) 012: 12 VDC
024: 24 VDC (refer to the COIL DATA CHART)
(f) Contact Rating Nil : Standard
–K : K type (1 pole ONLY)
(g) Safety Standards Nil : UL 508 recognized
–CSA: UL 508 + CSA recognized
–T : VDE + UL 508 + CSA recognized
Only for 1 form C and 1 form A standard types, without -K or does
not apply to -K type
(refer to the SAFETY AND FILE NUMBERS)
Note: The designation name is stamped on the top of the relay case as follows:
(Example) Designation ordered: FBR611ND024
Stamp: 611ND024
FEATURES
Maximum switching capacity of 30 VDC,16 A and 240
VAC, 16 A (single pole, K type)
5 kV AC minimum dielectric strength (between coil and
contacts)
10 kV minimum surge strength (between coil and con
tacts)
Coil terminal separated from output terminals to allow
easy PC board design
High reliability design conforming to safety standards
Japan Electrical Appliance Control Law (150–300 V)
ORDERING INFORMATION
FBR6 1 3 N D012 –K –CSA
[Example] (a) (b) (c) (d) (e) (f) (g)
FBR610, 620 SERIES
FUJITSU TAKAMISAWA
COMPONENT CATALOG
POWER RELAY
1, 2 POLES5, 10, 16 A
232
UL 508
2
FBR610, 620 SERIES
NOT FOR NEW
DESIGNS
Safety Standard
Type Nominal voltage Contact ratings
UL CSA VDE
1 form C, 1 form A recognized recognized recognized UL 10 A 240 VAC resistive
CSA 10 A 30 VDC resistive
1 form B 1/2 HP 240 VAC, 1/3 HP
120 VAC
1 form C UL 10 A 240 VAC resistive
CSA 10 A 30 VDC resistive
recognized recognized
1 form A, 1 form B 5 to 60 VDC UL 16 A 240 VAC resistive
CSA 10 A 30 VDC resistive
1/2 HP 240 VAC, 1/3 HP
120 VAC
UL 10 A 240 VAC resistive
10 A 30 VDC resistive
1/2 HP 240 VAC, 1/3 HP
120 VAC
standard recognized recognized CSA 6 A 240 VAC resistive
6 A 30 VDC resistive
SAFETY STANDARD AND FILE NUMBERS
UL508, (File No. E63614)
C 22.2 No. 0, No. 14 (File No. LR40304 or LR64026)
VDE 0435, 0860 (File No. 5304UG)
1 Pole
2 Poles K type
Standard
3
FBR610, 620 SERIES
NOT FOR NEW
DESIGNS
1 Pole type
Item K type 2 Poles type
Standard 1 form A, B 1 form C
Contact Arrangement 1 form C, A, B 1 form A, B 1 form C 2 form C, A, B
Material Silver-cadmium oxide
Resistance (initial) Maximum 100 m (at 1 A 6 VDC)
Ratings (resistive load) 10 A 240 VAC 16 A 240 VAC 10 A 240 VAC 5 A 240 VAC
10 A 30 VDC 16 A 30 VDC 10 A 30 VDC 5 A 30 VDC
Maximum Carrying Current 14 A 16 A 7 A
Maximum Switching Power
Max. Switching Voltage*1250 VAC or 125 VDC
Minimum Switching Load*20.5 W (5 V, 100 mA)
Coil
Power Consumption Rated
Approximately 0.5 W (at 20°C)
Operate
Approximately 0.35 W (at 20°C)
Operating Temperature –40°C to +70°C (no frost) (refer to the CHARACTERISTIC DATA) *3
Operating Humidity 45 to 85%RH
Time Value
Operate (at nominal voltage)
Maximum 15 ms
Release (at nominal voltage)
Maximum 5 ms
Insulation Resistance (initial) Minimum 100 M (at 500 VDC)
Dielectric Between open contacts
1,000 VAC 1 minute
Strength
Between coil and contacts
5,000 VAC 1 minute
Between adjacent 3,000 VAC
contacts 1 minute
Surge Strength 10,000 V (at 1.2 × 50 µs)
Life Mechanical 20 × 106 operations minimum
Electical (refer to
DC
1 × 105 operations minimum (at contact rating)
the REFERENCE DATA)
AC 2 × 10 5 ops. min.
1 × 105 operations minimum (at contact rating)
Other Vibration Misoperation 10 to 55 Hz (double amplitude of 1.5 mm)
Resistance
Endurance 10 to 55 Hz (double amplitude of 1.5 mm)
Shock Misoperation 100 m/s2 (11 ±1 ms)
Resistance
Endurance 500 m/s 2 (11 ±1 ms)
Weight Approximately 16 g
*1 If the switching voltage exceeds the rated contact voltage.
*2
Values when switching a resistive load at normal room temperature and humidity, and in a clean environment. The minimum
switching load varies with the switching frequency and operation environment.
*3 Based on UL Class A coil insulation system.
SPECIFICATIONS
2,400VA or 300W
3,840VA or 480W 2,400 VA or 300W 1,200 VA or 150 W
4
FBR610, 620 SERIES
NOT FOR NEW
DESIGNS
COIL DATA CHART
MODEL
1 Pole type 2 Poles type
Standard K type Standard
FBR611, 611N FBR621, 621N
FBR613, 613N FBR623, 623N
FBR615, 615N FBR625, 625N
FBR61D005 FBR61D005-K FBR62D005 5 VDC 50 100 mA
FBR61D006 FBR61D006-K FBR62D006 6 VDC 72 83 mA
FBR61D009 FBR61D009-K FBR62D009 9 VDC 160 56 mA
FBR61D012 FBR61D012-K FBR62D012 12 VDC 285 42 mA
FBR61D018 FBR61D018-K FBR62D018 18 VDC 640 28 mA
FBR61D024 FBR61D024-K FBR62D024 24 VDC 1,150 21 mA
FBR61D048 FBR61D048-K FBR62D048 48 VDC 4,600 10 mA
FBR61D060 FBR61D060-K FBR62D060 60 VDC 7,200 8 mA
Note: All values in the table are measured at 20°C.
Nominal
Nominal Coil
current
Must Must Maximum Nominal Coil
resistance
(at nominal
operate release
allowable
temperature
voltage (±10%)
voltage)
voltage voltage
voltage power
rise
approx.
70% max. 10% min.
Refer to
Approx. Approx.
of of
the
500 mW 35 deg
nominal nominal
REFERENCE
(at nominal (at nominal
voltage voltage
DATA
voltage) voltage)
5
FBR610, 620 SERIES
NOT FOR NEW
DESIGNS
REFERENCE DATA
Operation
Release Operation
Release
Distribution of operate and release voltage
80
60
40
20
01020 304050607080
0
Distribution (%)
Distribution (%)
Distribution (%)
Rated coil voltage multiplying factor (%)
Distribution of operate and release time
Contact resistance (m)
80
60
40
20
01020 304050607080
0
Distribution of contact resistance
Time (ms)
012 345678910
80
60
40
20
0
100
CHARACTERISTIC DATA
Maximum switching capacity (2 poles type)
Contact load voltage (V)
0.1
10 20 24030 50
1
120
0.3
0.5
2
3
5
Contact load current (A)
Coil temperature rise data
Coil power (W)
Coil temperature rise (°C)
20
30
40
50
60
70
80
0.2 0.4 0.6 0.8 1.0 1.2 1.4
Rated contact
carrying current
(at 20°C)
No contact
carrying current
Life curves (AC load)
Contact load current (A)
10
0
50
100
500
246810121416
18
240 VAC resistive load
1 pole standard and K type (1 form C)
1 pole K type
(1 form A, 1 form B)
2 poles type
Life curves (DC load)
Contact load current (A)
10
0
50
100
500
24681012
Service life (x10
4
operations)
Service life (x10
4
operations)
30 VDC resistive load
1 pole standard and K type
2 poles type
Maximum switching capacity (1 pole type)
Contact load voltage (V)
0.1
10 20 24030 50
2
120
0.3
0.5
3
5
10
Contact load current (A)
1
16
20
AC resistive load (K type)
( AC contact rating)
AC resistive load (standard)
( AC contact rating)
DC resistive load
( DC contact rating)
AC inductive load Cosø=0.4 (K type)
AC inductive load Cosø=0.4 (standard)
DC inductive load L/R = 7ms
AC resistive load
( AC contact rating)
DC resistive load)
( AC contact rating)
AC inductive load Cos ø = 0.4
DC inductive load L/R = 7 ms
Range of operation temperature and voltage
Operating temperature (°C)
Rated of operating voltage to rated coil voltage (V)
100 1020304050607080
70
80
90
100
110
120
130
140
150
160
170
180
Must operate voltage
Maximum allowable coil voltage
Rated contact carrying current
Data assumes that
the maximum
allowable tempera-
ture of E type
insulation coil is
115°C
Operating voltage range
No contact carrying current
6
FBR610, 620 SERIES
NOT FOR NEW
DESIGNS
DIMENSIONS
7.5
28.7+0.3
24.7+0.3
3.5±0.5
20
3.5
(6.0) (6.0) (6.0) (6.0) (6.0) (6.0)
(2.55)
(2.55)
(2.55)
(2.55)
(2.55)
(2.55)
3.5
7.5
28.7+0.3
20
5.0 5.0
7.5
28.7+0.3
20
3.5
7.5
28.7+0.3
20
5.0
7.5
28.7+0.3
20
3.5
7.5
28.7+0.3
20
5.0
12.6+0.4
5
4
2
865
4
2
5
42
85
4
5
4
13
786
2
65
4
87
12
7
2
6
3
7.5
±0.1
3.5
±0.1
3.5
±0.1
5–ø 1.3
+0.1
–0
20
±0.1
7.5
±0.1
7.5
±0.1
5.0
±0.1
5.0
±0.1
8–ø 1.3
+0.1
–0
20
±0.1
3.5
±0.1
4–ø 1.3
+0.1
–0
20
±0.1
5.0
±0.1
6–ø 1.3
+0.1
–0
20
±0.1
3.5
±0.1
4–ø 1.3
+0.1
–0
20
±0.1
5.0
±0.1
6–ø 1.3
+0.1
–0
20
±0.1
7.5
±0.1
7.5
±0.1
7.5
±0.1
7.5
(2.55)
28.7+0.3
(2.55)
(2.55)
20
5.0
(6.0) (6.0) (6.0)
5.0
24.7+0.3
3.5±0.5
12.6+0.4
7.5
28.7+0.3
20
5.0 5.0
7.5
28.7+0.3
20
5.0
2
5
4
13
786
2
5
4
1
78
2
5
4
3
76
7.5
±
0.1
5.0
±0.1
5.0
±0.1
8–ø 1.3
+0.1
–0
20
±0.1
7.5
±
0.1
5.0
±0.1
6–ø 1.3
+0.1
–0
20
±0.1
7.5
±
0.1
5.0
±0.1
6–ø 1.3
+0.1
–0
20
±0.1
1. 1 Pole type
(All types are in
common)
1 form C 1 form A 1 form B
Standard K type Standard K type Standard K type
Schematics
(BOTTOM VIEW)
Note: The terminal
number is not
shown on the relay.
PC board mount-
ing hole layout
(BOTTOM VIEW)
2. 2 Poles type 2 form C
(All types are in
common)
2 form B2 form A
Schematics
(BOTTOM VIEW)
Note: The terminal
number is not
shown on the relay.
PC board mount-
ing hole layout
(BOTTOM VIEW)
Unit: mm
7
FBR610, 620 SERIES
NOT FOR NEW
DESIGNS
Japan
Fujitsu Takamisawa Component Limited
Global Marketing and Sales
Gotanda-Chuo Building
3-5, Higashigotanda 2-chome, Shinagawa-ku
Tokyo 141, Japan
Tel: (81-3) 5449-7010
Fax: (81-3) 5449-2626
North and South America
Fujitsu Takamisawa America, Inc.
250 E. Caribbean Drive
Sunnyvale, CA 94089 U.S.A.
Tel: (1-408) 745-4900
Fax: (1-408) 745-4970
Europe
Fujitsu Takamisawa Europe B.V.
Diamantlaan 25
2132 WV Hoofddorp
Netherlands
Tel: (31-23) 5560910
Fax: (31-23) 5560950
Asia Pacific
Fujitsu Takamisawa Asia Pacific Pte. Ltd.
102E Pasir Panjang Road
#04-01 Citilink Warehouse Complex
Singapore 118529
Tel: (65) 375-8560
Fax: (65) 273-3021
Fujitsu Takamisawa
International
Headquarter
Offices
www.fujitsu.takamisawa.com