02/11/2015 www.crouzet.com "Application-specific" and grouping adapted kits Kit 20 Part number 88970808 Discover just what Millenium 3 can do for you - its complete kits provide everything you need for your application Product groups : in order to facilitate logistics, we can supply groups of products Part numbers 88970808 Type Description Kit 20 CD20 Essential - 24 V DC (Ref. 88970051) + 1 Power supply PS24-60 W (Ref. 88950302) Specifications General environment characteristics for CB, CD, XD, XB, XR and XE product types Certifications Conformity to standards (with the low voltage directive and EMC directive) Earthing Protection rating Overvoltage category Pollution Max operating Altitude Mechanical resistance Resistance to electrostatic discharge Resistance to HF interference Conducted and radiated emissions Operating temperature Storage temperature Relative humidity Mounting Screw terminals connection capacity CE, UL, CSA, GL IEC/EN 61131-2 (Open equipment) IEC/EN 61131-2 (Zone B) IEC/EN 61000-6-2, IEC/EN 61000-6-3 (*) IEC/EN 61000-6-4 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) Not included In accordance with IEC/EN 60529 : IP40 on front panel IP20 on terminal block 3 in accordance with IEC/EN 60664-1 Degree : 2 in accordance with IEC/EN 61131-2 Operation : 2000 m Transport : 3048 m Immunity to vibrations IEC/EN 60068-2-6, test Fc Immunity to shock IEC/EN 60068-2-27, test Ea Immunity to ESD IEC/EN 61000-4-2, level 3 Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode IEC/EN 61000-4-6, level 3 Voltage dips and breaks (AC) IEC/EN 61000-4-11 Immunity to damped oscillatory waves IEC/EN 61000-4-12 Class B (*) in accordance with EN 55022, EN 55011 (CISPR22, CISPR11) group 1 (*) Except configuration (88 970 1.1 or 88 970 1.2) + (88 970 250 or 88 970 270) + 88 970 241 class A (class B in a metal enclosure) -20 +70 C except CB and XB versions in VDC : -30 +70 C (+40 C in a non-ventilated enclosure) in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-22 -40 +80 C in accordance with IEC/EN 60068-2-1 and IEC/EN 60068-2-2 95 % max. (no condensation or dripping water) in accordance with IEC/EN 60068-2-30 On symmetrical DIN rail, 35 x 7.5 mm and 35 x 15 mm, or on panel (2 x O 4 mm) Flexible wire with ferrule = 1 conductor : 0.25 to 2.5 mm2 (AWG 24...AWG 14) 2 conductors 0.25 to 0.75 mm2 (AWG 24...AWG 18) Semi-rigid wire = 1 conductor : 0.2 to 2.5 mm2 (AWG 25...AWG 14) Rigid wire = 1 conductor : 0.2 to 2.5 mm2 (AWG 25...AWG 14) 2 conductors 0.2 to 1.5 mm2 (AWG 25...AWG 16) Tightening torque = 0.5 N.m (4.5 lb-in) (tighten using screwdriver diam. 3.5 mm) Also valid for spring cage connectors (ref 88 970 313 and 88 970 317 for the RBT range) Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Processing characteristics of CB, CD, XD & XB product types LCD display Programming method Program size Program memory Removable memory Data memory Back-up time in the event of power failure Cycle time Response time Clock data retention Clock drift Timer block accuracy Start up time on power up CD, XD : Display with 4 lines of 18 characters Function blocks / SCF (Grafcet) or Ladder 8 Kb : 350 typical blocks, 64 macros maximum, 256 blocks maximum per macro or 120 lines in Ladder Flash EEPROM EEPROM 368 bit/200 words Program and settings in the controller : 10 years Program and settings in the plug-in memory : 10 years Data memory : 10 years FBD : 6 90 ms (typically 20 ms) Ladder : typically 20 ms Input acquisition time : 1 to 2 cycle times 10 years (lithium battery) at 25 C Drift < 12 min/year (at 25 C) 6 s/month (at 25 C with user-definable correction of drift) 1 % 2 cycle times < 1,2 s Characteristics of products with AC power supplied Supply Nominal voltage Operating limits Supply frequency range Immunity from micro power cuts Max. absorbed power Isolation voltage 24 V AC -15 % / +20 % or 20.4 V AC28.8 V AC 50/60 Hz (+4 % / -6 %) or 47 53 Hz/57 63 Hz 10 ms (repetition 20 times) CB12-CD12-XD10-XB10 : 4 VA CB20-CD20 : 6 VA XD10-XB10 with extension : 7.5 VA XD26-XB26 : 7.5 VA XD26-XB26 with extension : 10 VA 1780 V AC 100 240 V AC -15 % / +10 % or 85 V AC264 V AC 50/60 Hz (+ 4 % / - 6 %) or 47 53 Hz/57 63 Hz 10 ms (repetition 20 times) CB12-CD12-XD10-XB10 : 7 VA CB20-CD20 : 11 VA XD10-XB10 with extension : 12 VA XD26-XB26 : 12 VA XD26-XB26 with extension : 17 VA 1780 V AC Inputs Input voltage Input current Input impedance Logic 1 voltage threshold Making current at logic state 1 Logic 0 voltage threshold Release current at logic state 0 Response time with LADDER programming Response time with function blocks programming Maximum counting frequency Sensor type Input type Isolation between power supply and inputs Isolation between inputs Protection against polarity inversions Status indicator 24 V AC (-15 % / +20 %) 4.4 mA @ 20.4 V AC 5.2 mA @ 24.0 V AC 6.3 mA @ 28.8 V AC 4.6 k 14 V AC > 2 mA 5 V AC < 0.5 mA 50 ms State 0 1 (50/60 Hz) Configurable in increments of 10 ms 50 ms min. up to 255 ms State 0 1 (50/60 Hz) In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr) Contact or 3-wire PNP Resistive None None Yes On LCD screen for CD and XD 100 240 V AC (-15 % / +10 %) 0.24 mA @ 85 V AC 0.75 mA @ 264 V AC 350 k 79 V AC > 0.17 mA 20 V AC ( 28 V AC : XE10, XR06, XR10, XR14) < 0.5 mA 50 ms State 0 1 (50/60 Hz) Configurable in increments of 10 ms 50 ms min. up to 255 ms State 0 1 (50/60 Hz) In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr) Contact or 3-wire PNP Resistive None None Yes On LCD screen for CD and XD Characteristics of relay outputs common to the entire range Max. breaking voltage Breaking current Electrical durability for 500 000 operating cycles Max. Output Common Current Minimum switching capacity Minimum load Maximum rate Mechanical life Voltage for withstanding shocks Off-cycle response time Built-in protections Status indicator 5 30 V DC 24 250 V AC CB-CD-XD10-XB10-XR06-XR10 : 8 A XD26-XB26 : 8 x 8 A relays, 2 x 5 A relays XE10 : 4 x 5 A relays XR14 : 4 x 8 A relays, 2 x 5 A relays RBT (Removable Terminal Blocks) versions : verify the maximum current according to the type of connection used Utilization category DC-12 : 24 V, 1.5 A Utilization category DC-13 : 24 V (L/R = 10 ms), 0.6 A Utilization category AC-12 : 230 V, 1.5 A Utilization category AC-15 : 230 V, 0.9 A 12 A for O8, O9, OA 10 mA (at minimum voltage of 12 V) 12 V, 10 mA Off load : 10 Hz At operating current : 0.1 Hz 10,000,000 (operations) In accordance with IEC/EN 60947-1 and IEC/EN 60664-1 : 4 kV Make 10 ms Release 5 ms Against short-circuits : None Against overvoltages and overloads : None On LCD screen for CD and XD Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 www.crouzet.com Characteristics of product with DC power supplied Supply Nominal voltage Operating limits Immunity from micro power cuts Max. absorbed power Protection against polarity inversions 12 V DC -13 % / +20 % or 10.4 V DC14.4 V DC (including ripple) 1 ms (repetition 20 times) CB12 with solid state outputs : 1.5 W CD12 : 1.5 W CD20 : 2.5 W XD26-XB26 : 3 W XD26-XB26 with extension : 5 W XD26 with solid state outputs : 2.5 W Yes 24 V DC -20 % / +25 % or 19.2 V DC30 V DC (including ripple) 1 ms (repetition 20 times) CB12-CD12-CD20 with solid state outputs - XD10-XB10 with solid state outputs : 3 W XD10-XB10 with relay outputs : 4 W XD26-XB26 with solid state outputs : 5 W CB20-CD20 with relay outputs : 6 W XD26 with relay outputs : 6 W XD10-XB10 with extension : 8 W XD26-XB26 with extension : 10 W Yes Digital inputs (I1 to IA and IH to IY) Input voltage Input current Input impedance Logic 1 voltage threshold Making current at logic state 1 Logic 0 voltage threshold Release current at logic state 0 Response time Maximum counting frequency Sensor type Conforming to IEC/EN 61131-2 Input type Isolation between power supply and inputs Isolation between inputs Protection against polarity inversions Status indicator 12 V DC (-13 % / +20 %) 3.9 mA @ 10.44 V DC 4.4 mA @ 12.0 V DC 5.3 mA @ 14.4 VDC 2.7 k 7 V DC 2 mA 3 V DC < 0.9 mA 1 2 cycle times + 6 ms Inputs I1 & I2 : FBD (up to 6 k Hz) & Ladder (1 k Hz) Inputs I3 to IA & IH to IY : In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr) Contact or 3-wire PNP Type 1 Resistive None None Yes On LCD screen for CD and XD 24 V DC (-20 % / +25 %) 2.6 mA @ 19.2 V DC 3.2 mA @ 24 V DC 4.0 mA @ 30.0 VDC 7.4 k 15 V DC 2.2 mA 5 V DC < 0.75 mA 1 2 cycle times + 6 ms Inputs I1 & I2 : FBD (up to 6 k Hz) & Ladder (1 k Hz) Inputs I3 to IA & IH to IY : In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr) Contact or 3-wire PNP Type 1 Resistive None None Yes On LCD screen for CD and XD 4 inputs IB IE 6 inputs IB IG 4 inputs IB IE 6 inputs IB IG (0 10 V) or (0 V power supply) 14 k 14.4 V DC max. 14 mV Common mode 10 bit at max. input voltage Controller cycle time 5% 6.2 % 2% None 10 m maximum, with shielded cable (sensor not isolated) Yes 2.2 k/0.5 W (recommended) 10 k max. (0 10 V) or (0 V power supply) 12 k 30 V DC max. 29 mV Common mode 10 bit at max. input voltage Controller cycle time 5% 6.2 % 2% None 10 m maximum, with shielded cable (sensor not isolated) Yes 2.2 k/0.5 W (recommended) 10 k max. 12 V DC (-13 % / +20 %) 0.7 mA @ 10.44 VDC 0.9 mA @ 12.0 VDC 1.0 mA @ 14.4VDC 14 k 7 V DC 0.5 mA 3 V DC 0.2 mA 1 2 cycle times In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr) Contact or 3-wire PNP Type 1 Resistive None None Yes On LCD screen for CD and XD 24 V DC (-20 % / +25 %) 1.6 mA @ 19.2 VDC 2.0 mA @ 24.0 V DC 2.5 mA @ 30.0 VDC 12 k 15 VDC 1.2 mA 5 V DC 0.5 mA 1 2 cycle times In accordance with cycle time (Tc) and input response time (Tr) : 1/ ( (2 x Tc) + Tr) Contact or 3-wire PNP Type 1 Resistive None None Yes On LCD screen for CD and XD Analogue or digital inputs (IB to IG) CB12-CD12-XD10-XB10 CB20-CD20-XB26-XD26 Inputs used as analogue inputsonly in FBD Measurement range Input impedance Input voltage Value of LSB Input type Resolution Conversion time Accuracy at 25 C Accuracy at 55 C Repeat accuracy at 55 C Isolation between analogue channel and power supply Cable length Protection against polarity inversions Potentiometer control Inputs used as digital inputs Input voltage Input current Input impedance Logic 1 voltage threshold Making current at logic state 1 Logic 0 voltage threshold Release current at logic state 0 Response time Maximum counting frequency in FBD Sensor type Conforming to IEC/EN 61131-2 Input type Isolation between power supply and inputs Isolation between inputs Protection against polarity inversions Status indicator Characteristics of relay outputs common to the entire range Max. breaking voltage Max. Output Common Current 5 30 V DC 24 250 V AC 12A (10A UL) for O8, O9, OA Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected 02/11/2015 Breaking current Electrical durability for 500 000 operating cycles Minimum switching capacity Minimum load Maximum rate Mechanical life Voltage for withstanding shocks Off-cycle response time Built-in protections Status indicator www.crouzet.com CB-CD-XD10-XB10-XR06-XR10 : 8 A XD26-XB26 : 8 x 8 A relays, 2 x 5 A relays XE10 : 4 x 5 A relays XR14 : 4 x 8 A relays, 2 x 5 A relays Utilization category DC-12 : 24 V, 1.5 A Utilization category DC-13 : 24 V (L/R = 10 ms), 0.6 A Utilization category AC-12 : 230 V, 1.5 A Utilization category AC-15 : 230 V, 0.9 A 10 mA (at minimum voltage of 12 V) 12 V, 10 mA Off load : 10 Hz At operating current : 0.1 Hz 10,000,000 (operations) In accordance with IEC/EN 60947-1 and IEC/EN 60664-1 : 4 kV Make 10 ms Release 5 ms Against short-circuits : None Against overvoltages and overloads : None On LCD screen for CD and XD Digital / PWM solid state output PWM solid state output* * Only available with "FBD" programming language Breaking voltage Nominal voltage Nominal current Max. breaking current Voltage drop Response time Operating frequency Built-in protections Min. load Maximum incandescent load Galvanic isolation PWM frequency PWM cyclic ratio Max. Breaking current PWM Max. cable length PWM PWM accuracy at 120 Hz PWM accuracy at 500 Hz Status indicator CB12 : O4 XD26 : O4 O7 * Only available with "FBD" programming language 10.4 30 V DC 12-24 VDC 0.5 A 0,625 A 2 V for I = 0.5 A (at state 1) Make 1 ms Release 1 ms 1 Maximum on inductive load Against overloads and short-circuits : Yes Against overvoltages (*) : Yes Against inversions of power supply : Yes (*) In the absence of a volt-free contact between the logic controller output and the load 1 mA 0,2 A / 12 V DC 0,1 A / 24 V DC No 14.11 Hz 56.45 Hz 112.90 Hz 225.80 Hz 451.59 Hz 1806.37 Hz 0 100 % (256 steps for CD, XD and 1024 steps for XA) 50 mA 20 m < 5 % (20 % 80 %) load at 10 mA < 10 % (20 % 80 %) load at 10 mA On LCD screen for XD Unless otherwise specified, the characteristics given are applicable to all or part of the product range selected CD12-XD10-XB10 : O4 CD20-XD26-XB26 : O4 O7 19.2 30 V DC 24 V DC 0.5 A 0,625 A 2 V for I = 0.5 A (at state 1) Make 1 ms Release 1 ms 1 Maximum on inductive load Against overloads and short-circuits : Yes Against overvoltages (*) : Yes Against inversions of power supply : Yes (*) In the absence of a volt-free contact between the logic controller output and the load 1 mA 0,1 A / 24 V DC No 14.11 Hz 56.45 Hz 112.90 Hz 225.80 Hz 451.59 Hz 1806.37 Hz 0 100 % (256 steps for CD, XD and 1024 steps for XA) 50 mA 20 m < 5 % (20 % 80 %) load at 10 mA < 10 % (20 % 80 %) load at 10 mA On LCD screen for CD and XD Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Crouzet: 88970808