(888) IPD-CONVerters
(888) 473-2668
www.ipdconverters.com
C-44
50
55
60
65
70
75
80
85
90
95
12345678910
X10 = LOAD %
EFFICIENCY
%
HES033ZE
HES075ZG
HES100ZE
TECHNICAL SPECIFICATIONS
HES single output DC/DC converters provide up to
150 Watts of output power in an industry standard,
half-brick package and footprint. These units feature
ultra-high efficiency, Class A conducted noise specs, and
fixed switching frequency. The HES is designed with
open-frame packaging, along with planar magnetics to
provide maximum useable power with minimal thermal
constraints. The HES is especially suited to harsh
telecom, networking, and industrial applications, and is
fully compatible with production board washing
processes.
High Efficiency
Industry Standard Half-
Brick
Open-Frame Packaging
100°C Baseplate Operation
Water Washable
“True-Trim” Option
1500V Isolation
Positive or Negative
Logic
DESCRIPTION FEATURES
HES SERIES - 150 WATT
General
Turn-On Time 10 ms
Remote Shutdown Positive Or Negative Logic
Remote Shutdown Reference Vin Negative
Switching Frequency 2.5 & 3.3, 5V Model 200 kHz, 300 kHz (Respectively)
Isolation
Input - Output 1500 VDC
Input - Case 1050 VDC
Output - Case 500 VDC
Temperature Coefficient 0.2%/°C
Case Temperature
Operating Range -40 To +100°C
Storage Range -40 To +125°C
Thermal Shutdown Range 105 To 115°C
Vibration, 3 Axes, 5 Min Each 5 g, 10 - 55 Hz
MTBF (Bellcore Tr-nwt-000332) 1.8 X 106 hrs
Safety UL 1950, Csa 22.2-950, En60950
Weight (Approx.) 1.4 oz
Notes
1 Industrial temp range of -40 to +85C available, add suffix -I to P/N
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise
stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Efficiency vs. Load (48V Input)
Output
Setpoint Accuracy ±1%
Line Regulation Vin Min. - Vin Max., I out Rated 0.2% Vout
Load Regulation Iout Min. - Iout Max., Vin Nom. 0.2% Vout
Remote Sense Headroom 0.5 VDC
Minimum Output Current 10 %
Dynamic Regulation, Loadstep 25% Iout
Pk Deviation 4% Vout
Settling Time 500
µ
s
Voltage Trim Range ±10%
Short Circuit / Overcurrent Protection Shutdown / Hiccup
Current Limit Threshold Range, % of Iout Rated 110 - 130%
OVP Trip Range 120 - 140% Vout Nom.
OVP Type Self Recovering
Voltage Range
24 VDC Nominal 18 - 36 VDC
48 VDC Nominal 36 - 72 VDC
Reflected Ripple 50 mA
Input Reverse Voltage Protection Shunt Diode
Input Undervoltage Lockout / Hysteresis <34 V/1V Nom.
Input
C-45
Vin
(Volts)
Vin Range
(Volts)
Iin Max.*
(Amps)
Vout
(Volts)
Iout Rated
(Amps)
Ripple & Noise
Pk-Pk (mV)
Efficiency
Typ. ** Model
48
48
48
48
48
48
48
48
48
48
48
48
48
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
36 - 72
0.89
1.13
1.62
1.33
1.69
2.42
1.77
2.26
3.23
2.60
3.33
4.72
2.20
2.5
3.3
5
2.5
3.3
5
2.5
3.3
5
2.5
3.3
5
2.1
10
10
10
15
15
15
20
20
20
30
30
30
30
100
100
100
100
100
100
100
100
100
100
100
100
100
89%
87%
88%
86%
88%
89%
86%
85%
88%
82%
83%
86%
80%
HES025ZD-A
HES033ZE-A
HES050ZG-A
HES037ZD-A
HES050ZE-A
HES075ZG-A
HES050ZD-A
HES066ZE-A
HES100ZG-A
HES075ZD-A
HES100ZE-A
HES150ZG-A
HES063ZC-A
* Maximum input current at minimum input voltage, maximum rated output power.
** At nominal Vin, rated output.
MECHANICAL DRAWING
Thermal Impedance
Natural Convection 15.4 °C/W
100 LFM 12.2 °C /W
200 LFM 9.3 °C /W
300 LFM 7.4 °C /W
400 LFM 6.4 °C /W
Tolerances
Note:
Thermal impedance data is dependent on
many environmental factors. The exact
thermal performance should be validated for
specific application.
HES SERIES - 150 WATT
1 +V
in
2 -V
in
3 No Pin
(Shutdown)
4 +V
out
5 No Pin
(Trim)
6 -V
out
Inches: (Millimeters)
.XX ± 0.020 .X ± 0.5
.XXX ± 0.010 .XX ± 0.25
Pin:
± 0.002 ±
0.05
( Dimensions as listed unless otherwise specified.)
Pin Function
MODELS - (See the last page of this file for options.)
MOUNTING INSERTS
M3X.5 THROUGH 4PL
1.400"(35.6mm)
1.000"(25.4mm)
0.700"(17.8mm)
0.400"(10.2mm)
0
-0.50"(-12.7mm)
2.40"
(61.0mm)
2.28"
(57.9mm)
BOTTOM VIEW
1
2
3
4
5
6
7
8
9
0.18"
DIA 0.080"
DIA 0.040"
0.025" REF.
0.50"
(12.7mm)
(4.6mm)
(1.0mm)
(2.0mm)
(0.6mm)
0
1.900"
(48.3mm) -0.19"
(-4.8mm)
2PL
7PL
C105
OPTIONS
When ordering equipment options, use the following suffix information. Select the option(s) that
you prefer and add them to the model number. Example ordering options are located below the
options table.
OPTION SUFFIX APPLICABLE SERIES REMARKS
Negative Logic N HAS, HBD, HBS, HES, LES, QBS,
QES, TES, TQD TTL “Low” Turns Module ON
TTL “High” Turns Module OFF
Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES
Terminal Strip TS XWS, XWD, XWT
Trim 1 IAS, LES
Enable 2 IA D, IAS, LES, SMS
Trim and Enable 3 IAS, LES
Current Share 4 SMS
Headerless Y E ncapsulated EWS, IWS, OWS
PIN LENGTH AND HEAT SINK
OPTIONS Standard Pin Length is 0.180”
(4.6mm)
0.110” (2.8mm) Pin Length 8 All Units (Except SMS)
0.150” (3.8mm) Pin Length 9 All Units (Except SMS)
0.24” (6.1mm) Horizontal Heatsi nk 1H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal P ad
0.24” (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal P ad
0.45” (11.4mm) Horizontal
Heatsink 2H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal P ad
0.45” (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal P ad
0.95” (24.1mm) Horizontal
Heatsink 3H All Units (Except DIP, SIP, and SM
Packages) Includes Thermal P ad
0.95” (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM
Packages) Includes Thermal P ad
Example Opti ons:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and
0.95” vertical heatsink.
LES015YJ-3N = LES015YJ with optional trim and enable, negative logic.
QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110” pin length.
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.