(888) IPD-CONVerters (888) 473-2668 www.ipdconverters.com HES SERIES - 150 WATT DESCRIPTION FEATURES HES single output DC/DC converters provide up to 150 Watts of output power in an industry standard, half-brick package and footprint. These units feature ultra-high efficiency, Class A conducted noise specs, and fixed switching frequency. The HES is designed with open-frame packaging, along with planar magnetics to provide maximum useable power with minimal thermal constraints. The HES is especially suited to harsh telecom, networking, and industrial applications, and is fully compatible with production board washing processes. * High Efficiency * Industry Standard HalfBrick * Open-Frame Packaging * 100C Baseplate Operation * * * * Water Washable "True-Trim" Option 1500V Isolation Positive or Negative Logic Efficiency vs. Load (48V Input) 95 90 EFFICIENCY % 85 80 75 HES033ZE HES075ZG 70 HES100ZE 65 60 55 50 1 2 3 4 5 6 7 8 9 10 X10 = LOAD % General TECHNICAL SPECIFICATIONS Input Voltage Range 24 VDC Nominal 48 VDC Nominal Reflected Ripple Input Reverse Voltage Protection Input Undervoltage Lockout / Hysteresis Output Setpoint Accuracy Line Regulation Vin Min. - Vin Max., Iout Rated Load Regulation Iout Min. - Iout Max., Vin Nom. Remote Sense Headroom Minimum Output Current Dynamic Regulation, Loadstep Pk Deviation Settling Time Voltage Trim Range Short Circuit / Overcurrent Protection Current Limit Threshold Range, % of Iout Rated OVP Trip Range OVP Type 18 - 36 VDC 36 - 72 VDC 50 mA Shunt Diode <34V/1V Nom. Turn-On Time Remote Shutdown Remote Shutdown Reference Switching Frequency 2.5 & 3.3, 5V Model Isolation Input - Output Input - Case Output - Case Temperature Coefficient Case Temperature Operating Range Storage Range Thermal Shutdown Range Vibration, 3 Axes, 5 Min Each MTBF (Bellcore Tr-nwt-000332) Safety Weight (Approx.) 1% 0.2% Vout 0.2% Vout 0.5 VDC 10 % 25% Iout 4% Vout 500 s 10% Shutdown / Hiccup 110 - 130% 120 - 140% Vout Nom. Self Recovering C-44 10 ms Positive Or Negative Logic Vin Negative 200 kHz, 300 kHz (Respectively) 1500 VDC 1050 VDC 500 VDC 0.2%/C -40 To +100C -40 To +125C 105 To 115C 5 g, 10 - 55 Hz 1.8 X 106 hrs UL 1950, Csa 22.2-950, En60950 1.4 oz Notes 1 Industrial temp range of -40 to +85C available, add suffix -I to P/N MTBF predictions may vary slightly from model to model. Specifications typically at 25C, normal line, and full load, unless otherwise stated. Soldering Conditions: I/O pins, 260C, ten seconds; fully compatible with commercial wave-soldering equipment. Safety: Agency approvals may vary from model to model. Please consult factory for specific model information. Units are water-washable and fully compatible with commercial spray or immersion post wave-solder washing equipment. HES SERIES - 150 WATT MODELS - (See the last page of this file for options.) Vin (Volts) Vin Range (Volts) Iin Max.* (Amps) Vout (Volts) Iout Rated (Amps) Ripple & Noise Pk-Pk (mV) Efficiency Typ. ** Model 48 48 48 48 48 48 48 48 48 48 48 48 48 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 36 - 72 0.89 1.13 1.62 1.33 1.69 2.42 1.77 2.26 3.23 2.60 3.33 4.72 2.20 2.5 3.3 5 2.5 3.3 5 2.5 3.3 5 2.5 3.3 5 2.1 10 10 10 15 15 15 20 20 20 30 30 30 30 100 100 100 100 100 100 100 100 100 100 100 100 100 89% 87% 88% 86% 88% 89% 86% 85% 88% 82% 83% 86% 80% HES025ZD-A HES033ZE-A HES050ZG-A HES037ZD-A HES050ZE-A HES075ZG-A HES050ZD-A HES066ZE-A HES100ZG-A HES075ZD-A HES100ZE-A HES150ZG-A HES063ZC-A * Maximum input current at minimum input voltage, maximum rated output power. ** At nominal Vin, rated output. MECHANICAL DRAWING 0.18" 2.28" (57.9mm) (4.6mm) MOUNTING INSERTS M3X.5 THROUGH 4PL 1 5 1.400"(35.6mm) 2 6 1.000"(25.4mm) 7 0.700"(17.8mm) 3 8 0.400"(10.2mm) 4 9 DIA 0.080" (2.0mm) 2PL 2.40" BOTTOM VIEW (61.0mm) DIA 0.040" 0 (1.0mm) 7PL -0.50"(-12.7mm) 0.025" REF. 1.900" 0 (48.3mm) Thermal Impedance Natural Convection 100 LFM 200 LFM 300 LFM 400 LFM 15.4 12.2 9.3 7.4 6.4 C/W C/W C/W C/W C/W (0.6mm) -0.19" (-4.8mm) Pin 0.50" (12.7mm) Function 1 +Vin 2 3 -Vin No Pin (Shutdown) 4 5 +Vout No Pin (Trim) 6 -Vout Note: Thermal impedance data is dependent on many environmental factors. The exact thermal performance should be validated for specific application. C-45 Tolerances Inches: .XX 0.020 .XXX 0.010 Pin: 0.002 (Millimeters) .X 0.5 .XX 0.25 0.05 ( Dimensions as listed unless otherwise specified.) OPTIONS When ordering equipment options, use the following suffix information. Select the option(s) that you prefer and add them to the model number. Example ordering options are located below the options table. OPTION SUFFIX APPLICABLE SERIES Negative Logic N HAS, HBD, HBS, HES, LES, QBS, QES, TES, TQD Lucent Compatible Trim T HAS, HBD, HBS, HES, QBS, QES Terminal Strip TS REMARKS TTL "Low" Turns Module ON TTL "High" Turns Module OFF XWS, XWD, XWT Trim 1 IAS, LES Enable 2 IAD, IAS, LES, SMS Trim and Enable 3 IAS, LES Current Share 4 SMS Headerless Y Encapsulated EWS, IWS, OWS PIN LENGTH AND HEATSINK OPTIONS Standard Pin Length is 0.180" (4.6mm) 0.110" (2.8mm) Pin Length 8 All Units (Except SMS) 0.150" (3.8mm) Pin Length 9 All Units (Except SMS) 0.24" (6.1mm) Horizontal Heatsink 1H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.24" (6.1mm) Vertical Heatsink 1V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.45" (11.4mm) Horizontal Heatsink 2H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.45" (11.4mm) Vertical Heatsink 2V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.95" (24.1mm) Horizontal Heatsink 3H All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad 0.95" (24.1mm) Vertical Heatsink 3V All Units (Except DIP, SIP, and SM Packages) Includes Thermal Pad Example Options:HBS050ZG-ANT3V = HBS050ZG-A with negative logic, Lucent compatible trim, and 0.95" vertical heatsink. LES015YJ-3N = LES015YJ with optional trim and enable, negative logic. QBS066ZG-AT8 = QBS066ZG-A with Lucent compatible trim and 0.110" pin length. NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the President of Power-One, Inc. TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. C105