1
VRRM Peak Repetitive Peak Reverse Voltage 200 V
IF(AV) Average Rectified Forward Current 8 A
Total Device, (Rated VR ), TC = 150°C
IFSM Non Repetitive Peak Surge Current 100
IFM Peak Repetitive Forward Current 16
(Rated VR , Square wave, 20 KHz), TC = 150°C
TJ, TSTG Operating Junction and Storage Temperatures -65 to 175 °C
Parameters Max Units
MUR820PbF
Bulletin PD-20898 12/04
trr = 25ns
IF(AV) = 8Amp
VR = 200V
Ultrafast Recovery Time
Low Forward Voltage Drop
Low Leakage Current
175°C Operating Junction Temperature
Lead-Free ("PbF" suffix)
Features
Description/ Applications
International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with
optimized performance of forward voltage drop and ultra fast recovery time.
The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as
free-wheeling diode in low voltage inverters and chopper motor drives.
Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
Absolute Maximum Ratings
Ultrafast Rectifier
www.irf.com
Case Styles
TO-220AC
MUR820PbF
Anode
13
Cathode
Base
Cathode
MUR820PbF
Bulletin PD-20898 12/04
2www.irf.com
VBR, VrBreakdown Voltage, 200 - - V IR = 100µA
Blocking Voltage
VFForward Voltage - - 0.975 V IF = 8A
- - 0.895 V IF = 8A, TJ = 150°C
IRReverse Leakage Current - - 5 µA VR = VR Rated
- - 250 µA TJ = 150°C, VR = VR Rated
CTJunction Capacitance - 25 - pF VR = 200V
LSSeries Inductance - 8.0 - nH .
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters Min Typ Max Units Test Conditions
Measured lead to lead 5mm from package body
trr Reverse Recovery Time --35 ns IF = 1.0A, diF/dt = 50A/µs, VR = 30V
--25 I
F = 0.5A, IR = 1.0A, IREC = 0.25A
-20- T
J = 25°C
34 TJ = 125°C
IRRM Peak Recovery Current - 1.7 - A TJ = 25°C
- 4.2 - TJ = 125°C
Qrr Reverse Recovery Charge - 23 - nC TJ = 25°C
-75 -T
J = 125°C
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
IF = 8A
VR = 160V
diF /dt = 200A/µs
Parameters Min Typ Max Units Test Conditions
Parameters Min Typ Max Units
TJMax. Junction Temperature Range - 65 - 175 °C
TStg Max. Storage Temperature Range - 65 - 175
RthJC Thermal Resistance, Junction to Case - - 3.0 °C/ W
RthJA Thermal Resistance, Junction to Ambient - - 50
RthCS Thermal Resistance, Case to Heatsink - 0.5 -
Wt Weight - 2.0 - g
- 0.07 - (oz)
Mounting Torque 6.0 - 12 Kg-cm
5.0 - 10 lbf.in
Marking Device MUR820
Thermal - Mechanical Characteristics
c Mounting Surface, Flat, Smooth and Greased
c
Bulletin PD-20898 12/04
3
MUR820PbF
www.irf.com
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
Fig. 1 - Typical Forward Voltage Drop Characteristics
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
0.1
1
10
100
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
T = 175˚C
T = 150˚C
T = 25˚C
J
J
J
0.001
0.01
0.1
1
10
100
0 50 100 150 200 250
150˚C
125˚C
100˚C
25˚C
T = 175˚C
J
10
100
1000
1 10 100 1000
T = 25˚C
J
Forward Voltage Drop - VFM (V)
Instantaneous Forward Current - I F
(A)
Reverse Voltage - VR (V)
Junction Capacitance - C T (pF)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
t1, Rectangular Pulse Duration (Seconds)
Thermal Impedance Z thJC (°C/W)
Reverse Current - I R
(µA)
0.01
0.1
1
10
0.00001 0.0001 0.001 0.01 0.1 1
Single Pulse
(Thermal Resistance)
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
2
t
1
t
P
DM
Notes:
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
MUR820PbF
Bulletin PD-20898 12/04
4www.irf.com
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
Fig. 6 - Forward Power Loss Characteristics
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC
;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR
Average Power Loss ( Watts )
trr ( nC )
0
2
4
6
8
10
036912
DC
RMS Limit
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
Qrr ( nC )
10
20
30
40
50
100 100
0
IF = 16A
IF = 8 A
IF = 4 A
V = 160V
T = 125˚C
T = 25˚C
R
J
J
0
40
80
120
160
200
100 100
0
IF = 16A
IF = 8 A
IF = 4 A
V = 160V
T = 125˚C
T = 25˚C
R
J
J
130
140
150
160
170
180
036912
DC
Square wave (D = 0.50)
Rated Vr applied
see note (2)
Average Forward Current - IF(AV)
(A)
Allowable Case Temperature (°C)
Average Forward Current - IF(AV)
(A)
Fig. 8 - Typical Stored Charge vs. di F /dtFig. 7 - Typical Reverse Recovery vs. di F /dt
di
F
/dt (A/µs )
di F
/dt (A/µs )
Bulletin PD-20898 12/04
5
MUR820PbF
www.irf.com
Fig. 10 - Reverse Recovery Waveform and Definitions
IRFP250
D.U.T.
L = 70µH
V = 200V
R
0.01
G
D
S
dif/dt
ADJUST
t
a
t
b
t
rr
Q
rr
I
F
I
RRM
I
RRM
0.5
di(rec)M/dt
0.75 I
RRM
5
4
3
2
0
1
di /dt
f
Fig. 9- Reverse Recovery Parameter Test Circuit
Reverse Recovery Circuit
di F /dt
di F /dt
4. Qrr - Area under curve defined by t rr
and IRRM
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
1. diF/dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going IF to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
Q rr = t rr x I RRM
2
MUR820PbF
Bulletin PD-20898 12/04
6www.irf.com
3.78 (0.15)
3.54 (0.14)
10.54 (0.41)
MAX.
DIA.
15.24 (0.60)
14.84 (0.58)
2.92 (0.11)
2.54 (0.10)
1
TERM 2
14.09 (0.55)
13.47 (0.53)
3.96 (0.16)
3.55 (0.14)
0.94 (0.04)
0.69 (0.03)
4.57 (0.18)
4.32 (0.17)
30.61 (0.02) MAX.
5.08 (0.20) REF.
1.32 (0.05)
1.22 (0.05)
6.48 (0.25)
6.23 (0.24)
0.10 (0.004)
1.40 (0.05)
1.15 (0.04)
2.89 (0.11)
2.64 (0.10)
1
3
2.04 (0.080) MAX.
Conforms to JEDEC Outline TO-220AC
Dimensions in millimeters and (inches)
Outline Table
Anode
13
Base
Cathode
Cathode
LOT CODE
ASSEMBLY
RECTIFIER
INTERNATIONAL
IRMX Assembly Line
EXAMPLE:
ASSEMBLED ON WW 19, 2001
IN THE ASSEMBLY LINE "C"
LOT CODE 1789 LOGO
P = LEAD-FREE
PART NUMBER
WEEK 19
YEAR 1 = 2001
DATE CODE
THIS IS A MUR820
Part Marking Information
LOT CODE
ASSEMBLY
RECTIFIER
INTERNATIONAL
IRXC Assembly Line
EXAMPLE:
ASSEMBLED ON WW 19, 2001
IN THE ASSEMBLY LINE "C"
LOT CODE 1789 LOGO
WEEK 19
LINE C
PART NUMBER
DATE CODE
YEAR 1 = 2001
P = LEAD-FREE
THIS IS A MUR820
Bulletin PD-20898 12/04
7
MUR820PbF
www.irf.com
Ordering Information Table
Device Code
124
3
1- Ultrafast MUR Series
2- Current Rating (8 = 8A)
3- Voltage Rating (20 = 200V)
4-y none = Standard Production
y PbF = Lead-Free
Tube Standard Pack Quantity : 50 pieces
MUR 8 20 PbF
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 12/04
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level and Lead-Free.