Technical Data 2151 Effective February 2016 Supersedes August 2014 Three-pole high SCCR UL Type 2 surge protective devices for three-phase Delta and Wye systems Standard local visual indication The green and red visual indicator flags show the module protective status (green = good, red = replace). Optional remote contact signaling Remote contact signaling available The three-pole terminal remote contact signaling option has a floating changeover contact for use as a break or make contact, according to circuit concept. Specifications: System volts easyIDTM local visual status indication * 208Vac * 480Vac * 600Vac Short-Circuit Current Rating (SCCR) * Catalog symbols: * BSPM3___WYG Up to 200kA Systems types * Three-phase Wye, 3 wire + ground * Three-phase Delta, 3 wire + ground * BSPM3___WYGR * BSPM3___DLG Agency information * BSPM3___DLGR * UL(R) Recognized 1449 4th Edition, Type 2 Component Assembly Description: * Vibration and shock tested per EN 60068-2 Eaton BussmannTM series three-pole UL modular surge arresters feature easyIDTM local visual indication and optional remote contact signaling for system monitoring. * CE * RoHS compliant The unique module locking system fixes the protection modules to the base and they can be easily replaced without tools by simply depressing the release buttons. * Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement. Mounting 35mm DIN-Rail Warranty * Five years Technical Data 2151 Three-pole high SCCR UL Type 2 surge protective devices for three-phase Delta and Wye systems Effective February 2016 Dimensions - mm: Module circuit diagrams: Shown with optional remote contact signaling L1 L2 L3 MOV 12 11 14 12 11 14 Optional remote contact signal Thermal disconnector Gnd Gnd BSPM3208WYG BSPM3480WYG BSPM3600WYG BSPM3240DLG BSPM3480DLG Shown with optional remote contact signaling. Typical installation/system application: L1 L2 L1 L2 L1 L2 L3 L3 L3 208, 480, 600Vac 208V, 480V, 600Vac Wye 3-phase, 3 wire + ground Wye 3-phase, 3 wire + ground BSPM3208WYG, BSPM3480WYG, BSPM3600WYG BSPM3208WYG, BSPM3480WYG, BSPM3600WYG 2 Eaton.com/bussmannseries 240, 480Vac Delta 3-phase, 3 wire + ground BSPM3240DLG, BSPM3480DLG Technical Data 2151 Three-pole high SCCR UL Type 2 surge protective devices for three-phase Delta and Wye systems Effective February 2016 Ordering information: Nominal system voltage 120/208Vac 240Vac Max. Continuous Operating AC Voltage MCOV 275/550Vac 275/550Vac (VC) [L-G/L-L] W/O remote signaling BSPM3208WYG BSPM3240DLG Catalog numbers (base + modules) W/ remote signaling BSPM3208WYGR BSPM3240DLGR Replacement module MOV technology BPM275UL BPM275UL 277/480Vac 480Vac 347/600Vac 385/770Vac 600/1200Vac 600/1200Vac BSPM3480WYG BSPM3480DLG BSPM3600WYG BSPM3480WYGR BSPM3480DLGR BSPM3600WYGR BPM385UL BPM600UL BPM600UL Specifications Rated voltage Voltage Protection Rating VPR [L-G/L-L] SCCR Discharge current Response time tA Frequency Number of poles Number of wires/connection points Operating state/fault indication Cross-sectional area Terminal torque Mounting Enclosure material Protection Location Capacity Application, standard Agency information Warranty Remote contact signaling Signaling type AC Switching capacity (volts/amps) DC Conductor and cross-sectional area Ordering information 120-127Vac, 208-220Vac 1kV/1.8kV 200kA 240Vac 277/480Vac 480Vac 347/600Vac 1kV/1.8kV 200kA 1.5kV/2.5kV 200kA 2kV/4kV 125kA 2kV/4kV 125kA Nom. In 20kA Max. Imax 40kA 25 ns 50/60Hz 3 3 wires / 4 connection points Green (good) / Red (replace) Min.. 14AWG - Cu stranded, solid or fine Max.. 2AWG - Cu solid or stranded, 4AWG - Cu fine 45 lb-in (5.1N*m) 35mm DIN-rail per EN 60715 Thermoplastic, UL 94V0 IP20 (finger-safe) Indoor 3 Mods, DIN 43880 UL Type 2 Component Assembly, UL 1449, 4th Edition cURus, RoHS Compliant Five years* Changeover contact 250V/0.5A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75C Max. 1.5mm2/14AWG solid/flexible Order from catalog numbers above * See Eaton Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Eaton.com/bussmannseries 3 Technical Data 2151 Three-pole high SCCR UL Type 2 surge protective devices for three-phase Delta and Wye systems Effective February 2016 The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States Eaton.com/bussmannseries (c) 2016 Eaton All Rights Reserved Printed in USA Publication No. 2151 -- BU-MC16XXX February 2016 Eaton and Bussmann are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. Follow us on social media to get the latest product and support information.