5Fifth Decision
Hardware & Accessories (Notes C and D)
Group IGroup II (Indicator Plate)Group V (Screw Terminal Options)
-00 No Outer Hardware Desired
-10 Black Knurled Nut
-11 Bright Nickel Knurled Nut
-20 Black Panel Dress Nut
-21 Bright Nickel Panel Dress Nut
-31 Bright Nickel Hex Nut
-C SAE 8-32, Upturned Lugs (Tabs)
Straight Terminal
-F M4, Upturned Lugs (Tabs)
Straight Terminal
-D SAE 8-32, Bus-Type Connect (Flat)
Straight Terminal
-H M4, Bus-Type Connect (Flat)
Straight Terminal
Please select a screw terminal option if you
selected “S” in Decision 1
-A Vertical Mount
(Off/On & O/I)*
-B Horizontal Mount
(Off/On & O/I)*
*Selection of A or B Indicator Plate
required for VDE and CCC.
Group III
-L Locking Ring
ON
I
Add “CV”
for Combined
markings.
ON
I
O
OFF
Step 3: Choose Handle Markings
Marked For Vertical Mount-After choice of 3 digit number in step 2 above.
Add “IV”
for Intíl.
markings.
I
O
Add “EV”
for English markings.
Example: "-W124EV"
ON
OFF
Add “CH”
for Combined
markings.
Marked For Horizontal Mount-After choice of 3 digit number in step 2 above.
Add “IH”
for International
markings.
O
Add “EH”
for English
markings.
Example “-W06EH”
OFF
OON
OFF I
If you have chosen a handle from this table, your 4th Decison and your catalog
part number are now complete (except if you require “-S” screw terminal option
from the 5th Decision Table.)
Third Decision
Rated Current
Circuit Breaker Construction
Use three numbers to print required
current value between .100 amps
minimum and 30.0 amps maximum.
For example, use:
.100 or 2.00 or 10.0
Switch Only Construction
-SW Maintained SPST & DPST
3
Second Decision
Frequency & Delay
2
-0 Instant DC-50/60 Hz
-1 Fast DC-50/60 Hz
-2 Slow DC-50/60 Hz
-3 Fast w/ Inertia Wheel
DC-50/60 Hz
-4 Slow w/ Inertia Wheel
DC-50/60 Hz
-41 Fast 400 Hz*
-42 Slow 400 Hz*
-49 Instant 400 Hz
-51 Fast DC+
-52 Slow DC+
-59 Instant DC+
-61 Fast 50/60 Hz*
-62 Slow 50/60 Hz*
-69 Instant 50/60 Hz
-S Switch Pole or Special Delay
1
2
First Decision
1
T Paddle Handle 1 Single Pole † 0 Switch Only (Note E)
PP Push-Pull 4 Single Pole †† 1 Series Circuit Protector
PR Push-To-Reset 2 Two Pole † 3 Shunt Circuit Protector
R Rocker 5 Two Pole †† 4 Relay Circuit Protector ††††
CR Rocker ** 5 Series w/ Silver Aux. Switch †††
CPP Push-Pull ** 6 Series w/ Gold Aux. Switch †††
CPR Push to Reset ** 9 Mixed Construction (Two Pole Only)
Quick Connects (leave blank)
S Screw Terminals,
Single pole (-1) and series only
(5th decision, group V - screw
terminal option is required
when 1st decision "S" is
specified)
† UL & CSA Construction
†† Non UL & CSA Construction
††† Auxilary Switch is located in the left hand pole (viewed from terminal end)
†††† Does not meet spacings for many IEC / VDE equipment specs.
Consult factory for additional information.
* Multi-pole units with mixed construction, poles numbered left to right when viewed
from terminal end. Shunt or relay construction available in pole 2 only, other pole must be a series
or switch only construction.
**UL 489A listed, available in 1 pole series or series w/silver aux. switch. DC delay only
Handle Poles Configurations* Terminals
1
-01 Black
-02 Red
-03 Yellow
-04 Green
-05 Blue
-06 White
If you have chosen a handle from this table, your 4th Decison is now
complete except for hardware options in 5th Decision Table.
Paddle (T) Handle Color
Step: 2: Choose Handle Combinations
Without Illumination Basic Handle Color (w/o Markings)
01 Black
02 Red
06 White
07 Orange
Example: “-W06”
101 Clear w/Neon (Note A)
102 Clear w/Green Glow Neon (Note A)
103 Clear w/Red LED (Note B)
104 Clear w/4-8 Vdc Red LED
105 Clear w/8-16 Vdc Red LED
107 Clear w/Green LED (Note B)
With Illumination Basic Handle Color & Light Choice (w/o Markings)
108 Clear w/4-8 Vdc Green LED
109 Clear w/8-16 Vdc Green LED
121 Transparent Red w/Neon (Note A)
123 Transparent Red w/Red LED (Note B)
124 Transparent Red w/Red LED 4-8 Vdc
125 Transparent Red w/Red LED 8-16 Vdc
161 Translucent White w/Neon (Note A)
162 Translucent White w/ Green Glow Neon (Note A)
171 Transparent Amber w/Neon (Note A)
181 Transparent Smoke Gray w/Neon (Note A)
182 Transparent Smoke Gray w/Green Glow Neon (Note A)
183 Transparent Smoke Gray w/Red LED (Note B)
184 Transparent Smoke Gray w/4-8 Vdc Red LED
185 Transparent Smoke Gray w/8-16 Vdc Red LED
187 Transparent Smoke Gray w/Green LED (Note B)
188 Transparent Smoke Gray w/4-8 Vdc Green LED
189 Transparent Smoke Gray w/8-16 Vdc Green LED
Example: “-W124”
If you prefer NO markings, then your handle decision is now complete.
Step 1: Choose Letter For Body Color
B Black
G Gray
W White
Rocker
R Black w/ Handle guard
S Gray w/ Handle guard
T White w/ Handle guard
Example: “W...”
For White Rocker Body (Rocker Style)
4Fourth Decision
-XX No Button Markings desired (not available for CPP & CPR)
-OA
-OB
-OC
Push-Pull (PP, CPP and CPR)
LINE
5
LINE
5
LINE
5
Marked Buttons Available For These Amperages
0.1
.25
0.5
.75
1
2.5
5
7.5
10
15
17.5
20
If you have chosen a handle from this table, your 4th Decison and your catalog part
number are now complete (except if you require “-S” screw terminal option from
the 5th Decision Table.)
-XX No Button Markings Only
If you have chosen a handle from this table, your 4th Decison and your catalog part number are
now complete (except if you require “-S” screw terminal option from the 5th Decision Table.)
Push-to-Reset (PR)
V = VDE, TÜV and CCC Approved
The shaded areas denote VDE, CCC (if applicable) and CE compliant options. The V will be
added to any part number formed entirely from shaded decisions. If non-shaded areas are
selected, the unit will not be VDE approved, nor CE compliant, but other approvals still apply.
*For addition of Inertia Delay an "F" may be added
to delay numbers 41, 42, 51, 52, 61 and 62 only.
+CR, CPP, CPR only available in these delays
T11 - 2- 5.00A - 01-11AL- V
1 2 3 4 5
T = TÜV Approved
This approval requires the addition of a T at the end of the PN. The unit will not be VDE approved. If
non-shaded areas are selected, the unit will not be TÜV approved, with the exception being you can select
screw terminals and screw terminal options (1st & 5th decision) as these options are TÜV approved.
HOW TO ORDER
The ordering code for the
SNAPAK® circuit protectors
may be determined by following
the steps in the decision tables
shown here.
The coding given permits a self-
assigning part number, with
certain limitations (due to the
adaptability of magnetic
protectors to complex circuits),
requires a factory-assigned part
number.
The example shown is the code
for a paddle handle, single pole
(UL construction), series
circuit protector designed for
operation of a 50/60Hz/DC
circuit. A slow time delay and
rating of 5 amperes has been
indicated. Handle color is black,
and a bright nickel knurled nut,
vertical mount (ON-OFF)
indicator plate and locking ring
are to be supplied.
To determine the ordering code
for your particular SNAPAK®
unit, simply follow the steps
shown, then fill in the letters
and/or numbers in the boxes.
Space is available on the circuit
breaker label for your part
number (up to 12 digits). You
may then use your own part
number to place an order or as
a reference for further
questions you may have. This
option does require a factory
assigned part number for
traceability to your drawing or
internal part number.
SNAPAK® Series - Decision Tables73
Notes:
A A neon bulb is provided when specified for 120Vac and 250Vac operation. For operation
at 120Vac a 33,000 ohm, 1/2 watt external resistor is required. At 250Vac a 100,000
ohm, 1 watt external resistor is required.
B An LED with 750 ft. L @ 20mA is provided in the center of the handle. Maximum power
dissipation @ 25°C is 135mW. Continuous forward current is 20mA. Forward voltage,
typical, is 1.6v at 20mA. Reverse current, typical, is 100mA @ 3.0 volts. An external
resistor may be required to limit current to these values.
C When ordering Paddle Handles, you may choose one item from each hardware group to add to 5th
decision if such items are desired. For example, “-11ALCA” would indicate a bright nickel knurled nut,
plus a vertical mount indicator, plus a locking ring, plus #8-32 screw terminal, straight with tabs.
D All units except Rocker units will have (1) hex nut installed as standard hardware for the back of a
panel. The choices in the fifth decision table are intended for the front or visible side of the panel and
are offered for Paddle Handle configuration only. Push-Pull and Push-to-Reset configurations include
one (1) panel nut and one (1) hex nut as standard hardware.
E Switch only — no current overload protection provided.
F. CCC Approval - If CCC is required on this product, please inform Sensata to have this product
manufacturered in our China facility