North America (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211Asia (HK): 852-2437-9662
1
Special Features
Electrical Specs
10 Watts
AEE00-12Vin
10 W, Dual output
2:1 Input range
1.0" x 2.0" x 0.33 case
Industry standard package
Low Profile
Low Cost
Operating base temperature range:
-25°C to +100°C
Storage temperature: -40°C to +125°C
MTBF: 3 Million Hours (Belcore TR332)
UL UL1950 Recognition
CSA CSA22.2-950 Recognition
TUV EN60950 Recognition
Input
Input range 9 to 18 VDC
Efficiency 78% typical (3.3V)
Output
Voltage tolerance ±1.0%
Overall regulation ±1% max
Noise/ripple 1% Typ, 2% Max
Transient response 300 usec typical (50% step load
change to within 3%Vo)
Temperature Regulation ±0.02 %Vo/°C
Switching frequency 330kHz
Isolation
I/O isolation 1500 VDC Input to Output
1000 VDC Input to Case
1000 VDC Output to Case
Isolation Resistance 300 Mohms
Total Power: 10 Watts
Input Voltages: 12V
No. of Outputs: Single and Dual
Environmental
Safety
EUROPE
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
AME RI CA S
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
2
Ordering Information
www.astecpower.com
ASIA
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Fwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
Input Output Efficiency Model Number
Voltage Voltage
9-18 V 3.3V @2.55 A 78% AEE02F12-49
9-18 V 5.0V @2 A 81% AEE02A12-49
9-18 V 12V @0.84 A 83% AEE00B12-49
9-18 V 15V @0.68 A 84% AEE00C12-49
9-18 V ±5V @±1.0 A 81% AEE01AA12-4
9-18 V ±12V @±0.42 A 83% AEE00BB12-4
9-18 V ±15V @±0.33 A 84% AEE00CC12-4
NOTES:
Enable Function
Trim Feature
Notes:
1. 20 MHz bandwidth. An external 0.1 uf ceramic capacitor
is recommended to be placed from +V out to comm.
2. All specifications are typical at nominal line, full load,
and 25°C unless otherwise noted.
3. All specifications subject to change without notice.
4. Mechanical drawings are for reference only.
Mechanical Dimensions and Pin Assignments
1. With the control pin floating (no connection), the unit is enabled and there is an output of 5V.
2. With the control pin Low (short to -Vin), the unit is enabled and there is an output of 5V.
3. With the control pin connected to an external logic signal (5V), the unit is disabled and there is no output.
“9” at end of Model Number designates Trim option.