Package Level 1 Height: 20 mm
Package Level 1 Length: 125 mm
Package Level 1 Gross Weight: 0.04 kg
Package Level 1 EAN: 3471523130043
Package Level 2 Units: 300 piece
Package Level 3 Units: 5400 piece
Product Packing Type: Bag
Tightening Torque UL/CSA: Auxiliary Circuit 11 in·lb
Connecting Capacity Auxiliary
Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Conventional Free-air Thermal
Current (I ):
acc. to IEC 60947-5-1, q = 40 °C 16 A
IIT Publishing Status: Level 0 - Information enabled
Maximum Electrical Switching
Frequency:
AC-15 1200 cycles per hour
DC-13 900 cycles per hour
Maximum Mechanical Switching
Frequency:
3600 cycles per hour
Mounted Auxiliary Contacts: 1 NO, 1 NC
Number of Auxiliary Contacts
NC:
1
Number of Auxiliary Contacts
NO:
1
Order Multiple: 1 piece
Product Main Type: Accessories for Block Contactors
Product Name: Auxiliary Contact Block
Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
Rated Impulse Withstand Voltage
(U ):
6 kV
Rated Insulation Voltage (U ): acc. to UL/CSA 600 V
acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Rated Operational Current AC-15
(I ):
(220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
Rated Operational Current DC-13
(I ):
(110 V) 0.55 A / 60 A
(125 V) 0.55 A / 69 A
(220 V) 0.27 A / 60 A
(24 V) 6 A / 144 A
(250 V) 0.27 A / 68 A
(400 V) 0.15 A / 60 A
(48 V) 2.8 A / 134 A
(500 V) 0.13 A / 65 A
(600 V) 0.1 A / 60 A
(72 V) 1 A / 72 A
Rated Operational Voltage: Auxiliary Circuit 24 ... 690 V
Rated Short-time Withstand for 0.1 s 140 A
Technical UL/CSA
Additional Information
th
imp
i
e
e