Rated voltage 760 VAC/600 VAC 50/60 Hz
Capacitance range 0.01 – 1.0 µF
Capacitance tolerance ± 20% standard, ± 10% option
Temperature range –40 to +105°C
Climatic category 40/105/56/B
Approvals ENEC, UL, CSA
Dissipation factor Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 0.47 µF C > 0.47 µF
1 kHz 0.1% 0.1% 0.1%
10 kHz 0.1% 0.2% 0.5%
100 kHz 0.6% 0.9% –
Test voltage between The 100% screening factory test is carried
terminals out at 4100 VDC. The voltage level is
selected to meet the requirements in
applicable equipment standards. All
electrical characteristics are checked
after the test.
Resonance frequency Tabulated self-resonance frequencies f0
refer to 5 mm lead length.
Insulation resistance C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
In DC application Recommended voltage: ≤1000VDC
PHE845
• EMI suppressor, class X1, metallized polypropylene
• 0.01 – 1.0 µF, 760 VAC/600VAC, +105°C
• New, small dimensions
TYPICAL APPLICATIONS CONSTRUCTION
TECHNICAL DATA
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
Metallized polypropylene winding,
encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
ENVIRONMENTAL TEST DATA
Endurance IEC384–14 1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration IEC68–2–6 3 directions at 2 hours each, No visible damage
Test Fc 10–55 Hz at 0.75 mm or 98 m/s2No open or short circuit
Bump IEC68–2–29 1000 bumps at No visible damage
Test Eb 390 m/s2No open or short circuit
Change of temperature IEC68–2–14 Upper and lower rated No visible damage
Test Na temperature 5 cycles
Active flammability EN 132400
Passive flammability IEC384-14 (1993) Enclosure material of
EN 132400 UL94V–0 flammability class
UL1414
Humidity IEC 68-2-3 +40°C and 56 days
Test Ca 90 – 95% R.H.
p d std l max l b
22.5 ± 0.4 0.8 6 30 ±0.4
27.5 ± 0.4 0.8 6 30 ±0.4
37.5 ± 0.5 1.0 6 30 ±0.7
Tolerance in lead length
< 30 mm mm
≥ 30 mm mm
+0
–1
+5
–0