PSB-120 Series (2 Phase) Features: Specifications OUTPUT Cat. No. PSB-12024 DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max) 24 V 5A 0-5A 120 W 100 mVp-p * Multiple overload/ short circuit protection modes * Efficiency above 91% * Small size * DIN rail mountable * Cooling by free air convection * UL508 (industrial control equipment) approved * EN60950-1 * Built-in DC OK relay contact * 3 year warranty Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1F & 47F parallel capacitor. VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE 22 V ~ 27 V -0.03 Tolerance: includes set up tolerance, line regulation and load regulation. DISSIPATION POWER LOAD mas LINE REGULATION LOAD REGULATION SETUP, RISE TIME 50,000 F 12A Max 2 sec.: Hiccup mode Permanent: Continuous mode 11 W 0.5% 1% 1 sec. (max) INPUT HOLD UP TIME (Typ.) Typ. 20 msec PROTECTION VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (115 - 230 Vac.) INRUSH CURRENT (Typ.) INTERNAL FUSE EXTERNAL FUSE (recommended) LEAKAGE CURRENT 187 ~ 264 V AC / 330 ~ 550V AC by switch 47 ~ 63 Hz +-6% >91 % 1.0 ~ 0.58 ~ 0.46A < 11 A < 5 msec T4A 10 A (MCB curve B) < 1.5 mA @ 230 Vac OVERLOAD ENVIRONMENT OVER VOLTAGE OVER TEMPERATURE SHORT CIRCUIT PROTECTION In (60C) x 1.5 3 min.; Current max. Overload @ 4Vdc (permanent) Imax=In (60C) x (1.8 ~ 2.2) 30 - 35 Vdc Yes. Shuts down output and automatically restarts when the temperature inside goes down 1 Hiccup Mode / 2 Fold Back / 3 Restart After Main - Selectable SAFETY & EMC DC OK AKTIV SIGNAL (max.) WORKING TEMP. HUMIDITY STORAGE TEMP TEMP. COEFFICIENT VIBRATION 20 ~ 30 Vdc -25 up to +70 C (>60derating 2.5% C) 95 % at 25C, no condensation -40 up to +85 C 0.03% / C (0 - 60 C) In according to IEC60068-2-6 SAFETY STANDARDS WITHSTAND VOLTAGE PROTECTION CLASS ISOLATION RESISTANCE EMI CONDUCTION & RADIATION HARMONIC CURRENT EMS IMMUNITY UL508 approved, IEC/EN 60950, EN 50178, IEC/EN 60950, EN60950-1, PELV EN 60204-1 I/P-O/P: 3k VAC I/P-FG: 1.6k VAC O/P-FG: 500 VAC IP 20 (EN/IEC 60529) 100 M (min) @ 500 Vdc EN61000-6-4 EN61000-3-2 EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN61000-6-2, START UP WITH STRONG LOAD CURRENT SHORT CIRCUIT Icc Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. The power supply is considered a component which will be installed into a final equipment. The final equipment must be OTHERS re-confirmed that it still meets EMC directives. MTBF IEC 61709 POLLUTION DEGREE CONNECTION TERMINAL BLOCK DIMENSION PACKING NOTE > 500.000 h 2 2.5 mm Screw (24 ~ 14 AWG) 55x110x105 mm ( 2.16x4.33x4.13 in ) 0.50 kg ( 1.1 lbs) each All parameters NOT specially mentioned are measured at 230V AC input, rated load and 25C of ambient temperature. For the latest on Altech Power Supply specifications please visit www.altechcorp.com/power. 50 Mechanical Specification 55 116 103 Cat. No.: PSB-12024 TB1 Terminal Pin. No Assignment Pin No. 1 2 3 Assignment (2 phase) N/L L/L FG TB2 Terminal Pin. No Assignment Pin No. 1,2 3,4 5,6 Assignment DC output -V DC output +V DC OK relay contacts DC OK Relay Contact Outputs are used for preventive function monitoring of the power supply. An electrically isolated signal contact is available. The signal contact closes when the output power is OK and opens when the output voltage falls below 20Vdc 5%. Output Derating Curve Note: All dimensions are in millimeters, to convert to inches multiply by 0.03937. Altech Corp.(R) * 35 Royal Road * Flemington, NJ 08822-6000 * Phone (908)806-9400 * FAX (908)806-9490 51