Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1412R Multi-Conductor - CMR Rated Cables For more Information please call 1-800-Belden1 General Description: 24 AWG stranded (7x32) TC conductor, polyolefin insulation, individually shielded Beldfoil(R) (100% coverage) numbered/color-coded PVC jackets, jackets and shields bonded to strip simultaneously, overall Beldfoil shield and 18 AWG TC drain wire. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material Dia. (mm) 16 24 7x32 TC - Tinned Copper 0.6096 Total Number of Conductors: 32 Insulation Insulation Material: Insulation Material Dia. (mm) PO - Polyolefin 1.016 Inner Shield Inner Shield Material: Inner Shield Trade Name Type Inner Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Inner Shield Drain Wire AWG: AWG 24 Inner Shield Drain Wire Stranding: 7x32 Inner Shield Drain Wire Conductor Material: TC - Tinned Copper Inner Jacket Inner Jacket Material: Inner Jacket Material Nom. Dia. (mm) PVC - Polyvinyl Chloride 2.8194 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 18 7x26 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material PVC - Polyvinyl Chloride Outer Jacket Ripcord: Yes Overall Cable Overall Cabling Color Code Chart: Page 1 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1412R Multi-Conductor - CMR Rated Cables Number Color 1 Brown and Numbered 1 2 Red and Numbered 2 3 Orange and Numbered 3 4 Yellow and Numbered 4 5 Green and Numbered 5 6 Blue and Numbered 6 7 Purple and Numbered 7 8 Gray and Numbered 8 9 White and Numbered 9 10 Black and Numbered 10 11 Tan and Numbered 11 12 Pink and Numbered 12 13 Gray/Brown Stripe and Numbered 13 14 Gray/Red Stripe and Numbered 14 15 Gray/Orange Stripe and Numbered 15 16 Gray/Yellow Stripe and Numbered 16 Overall Nominal Diameter: 15.799 mm Pair Pair Color Code Chart: Number Color 1 Red & Black Mechanical Characteristics (Overall) Operating Temperature Range: -30C To +75C Bulk Cable Weight: 321.451 Kg/Km Max. Recommended Pulling Tension: 1272.190 N Min. Bend Radius/Minor Axis: 157.988 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CMR CEC/C(UL) Specification: CMG EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1666 Riser CSA Flame Test: FT4 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Characteristic Impedance: Impedance (Ohm) Page 2 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1412R Multi-Conductor - CMR Rated Cables 50 Nom. Inductance: Inductance (H/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 101.711 Nom. Capacitance Cond. to Other Conductor & Shield: Capacitance (pF/m) 190.298 Nominal Velocity of Propagation: VP (%) 66 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 76.4473 Nominal Outer Shield DC Resistance: DCR @ 20C (Ohm/km) 19.686 Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 52.168 Ohm/km Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 1.05 Amps per conductor @ 25C Notes (Overall) Notes: Pair jackets and shields bonded so both strip simultaneously. Beldfoil(R) provides high reliability with ease of termination. Put Ups and Colors: Item # Putup Ship Weight Color Notes Item Desc 1412R 0101000 305 MT 105.234 KG BLACK C 16 #24 PR PO BFS PVC FS PVC 1412R 010500 152 MT 53.071 KG BLACK C 16 #24 PR PO BFS PVC FS PVC Notes: C = CRATE REEL PUT-UP. Revision Number: 1 Revision Date: 09-11-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 4 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 1412R Multi-Conductor - CMR Rated Cables Page 4 of 4 10-30-2013