INPUT CHARACTERISTICS: P1U-6180/6200P VOLTAGE: 90 ~ 264 VAC FULL RANGE FREQUENCY : 47 ~ 63 HZ INPUT CURRENT: 4.0 A ( RMS ) FOR 115VAC 2.0 A ( RMS ) FOR 230VAC INRUSH CURRENT: 65 A MAX. FOR 115 VAC 130 A MAX. FOR 230 VAC OUTPUT CHARACTERISTICS: OUTPUT VOLTAGE OUTPUT CURRENT REGULATION OUTPUT MIN. [A] MAX. [A] LOAD LINE RIPPLE & NOISE MAX. [P-P] 5V 2.0 16 5% 1% 70mV 12V 1.0 7 5% 1% 120mV -5V 0.1 0.2 5% 1% 100mV -12V 0.1 0.7 -10%~+10% 1% 120mV 3.3V 1.0 14 5% 1% 70mV +5VSB 0.1 1.5 5% 1% 70mV REMARKS: 1. THE OUTPUT POWER OF 5V & 3.3V NOT EXCEED 110 WATTS 2. TOTAL OUTPUT POWER NOT EXCEED 180 / 200 WATTS SPECIFICATION: TEMPERATURE RANGE: OPERATING 0 --- 40 HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND EFFICIENCY: 65% TYPICAL POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms OVER LOAD PROTECTION: 130 +/- 20% OVER VOLTAGE PROTECTION: +5V 5.6V ~ 6.6V, 3.3V 3.6 ~ 4.2V, 12V 13.2 ~ 14.6V SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC 950 REMOTE ON / OFF CONTROL THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY), AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE, AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE. 3.3V / 5V REMOTE SENSING COOLING: TWO 40mm DC FANS DIMENSION: 190 (D) x 100 (W) x 40 (H) mm ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D Revision: A01