INPUT CHARACTERISTICS: P1U-6180/6200P
VOLTAGE: 90 ~ 264 VAC FULL RANGE
FREQUENCY : 47 ~ 63 HZ
INPUT CURRENT: 4.0 A ( RMS ) FOR 115VAC
2.0 A ( RMS ) FOR 230VAC
INRUSH CURRENT: 65 A MAX. FOR 115 VAC
130 A MAX. FOR 230 VAC
OUTPUT CHARACTERISTICS:
OUTPUT CURRENT REGULATION OUTPUT
MIN. [A] MAX. [A] LOAD LINE
5V 2.0 16 ± 5% ± 1% 70mV
12V 1.0 7 ± 5% ± 1% 120mV
-5V 0.1 0.2 ± 5% ± 1% 100mV
-12V 0.1 0.7 -10%~+10% ± 1% 120mV
3.3V 1.0 14 ± 5% ± 1% 70mV
+5VSB 0.1 1.5 ± 5% ± 1% 70mV
OUTPUT
VOLTAGE RIPPLE & NOISE
MAX. [P-P]
REMARKS: 1. THE OUTPUT POWER OF 5V & 3.3V NOT EXCEED 110 WATTS
2. TOTAL OUTPUT POWER NOT EXCEED 180 / 200 WATTS
SPECIFICATION:
TEMPERATURE RANGE: OPERATING 0 --- 40
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND
INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND
EFFICIENCY: 65% TYPICAL
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 130 +/- 20%
OVER VOLTAGE PROTECTION: +5V 5.6V ~ 6.6V, 3.3V 3.6 ~ 4.2V,
12V 13.2 ~ 14.6V
SHORT CIRCUIT PROTECTION: +5V, -5V, +12V, -12V, +3.3V
EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS B
SAFETY: UL 1950, CSA 22.2 NO/ 950, TÜV IEC 950
REMOTE ON / OFF CONTROL
THE UNIT SHALL ACCEPT A LOGIC OPEN COLLECTOR LEVEL WHICH WILL
DISABLE / ENABLE ALL THE OUTPUT VOLTAGE (EXCLUDE +5V STANDBY),
AS LOGIC LEVEL IS LOW, OUTPUTS VOLTAGE WERE ENABLE,
AS LOGIC LEVEL IS HIGH, OUTPUTS VOLTAGE WERE DISABLE.
3.3V / 5V REMOTE SENSING
COOLING: TWO 40mm DC FANS
DIMENSION: 190 (D) x 100 (W) x 40 (H) mm
ACTIVE POWER FACTOR CORRECTION MEET IEC-1000-3-2 CLASS D
Revision: A01