BXA40 SERIES Single output * Pin-compatible with NFC40 Series * Meets telecom power supply interface standard ETS300-132-2 * EN60950, CSA C22.2 No. 950 and UL1950 safety approvals * EN61000-4-2, -3, -4, -5, -6 immunity compliant * Fixed frequency operation at 350kHz typ. * MTBF in excess of 500,000 hours * Basic insulation system with 1500V isolation * Remote sense on low voltage logic outputs * Output voltage trim The BXA40 Series providing up to 40 Watts, comprising 9 different models, has been conceived as an applications specific range of DC/DC converters, specifically addressing telecommunications, industrial electronics, test equipment, mobile telecommunications and distributed power applications. The series offers two wide input voltage ranges, 18-36VDC and 36-75VDC, and is available with single outputs from 2.9V to 15V. The BXA40 series is designed to meet ETSI telecoms interface standards ETS300-132-2. Together with internal filtering, safety approval to IEC950 and basic insulation, the 48VDC models are ideal for telecommunications applications. The 24V models are particularly suited to industrial and test equipment applications, featuring EN61000-4-2, -3, -4, -5 and -6 immunity compliance. Other features include low output ripple, overvoltage protection, indefinite short circuit protection, remote enable and remote sense. [ 2 YEAR WARRANTY ] SPECIFICATION All specifications are typical at nominal input, full load at 25C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Voltage adjustability Singles 10% Conducted emissions Line regulation Low line to high line 0.3% Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity Load regulation Full load to no load Ripple and noise (20MHz bandwidth) 2.9V and 3.3V 5.0V All other models All models 1.0% 30mV pk-pk 50mV pk-pk 100mV pk-pk 20mV rms EN55022, FCC part 15, (See Notes 4, 13) EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Level B Perf. Perf. Perf. Perf. Perf. Perf. Level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 GENERAL SPECIFICATIONS Temperature coefficient 0.02%/C Efficiency Overvoltage protection (See Note 9) 135% Vout Short circuit protection (See Note 10) Continuous Transient response 25% to 100% load (See Note 11) Voltage accuracy Remote sense (See Note 8) Isolation voltage Input/output input/case 4.0% Switching frequency Fixed 1.0% 5V, 2.0% 12V Approvals and standards (pending) EN60950, UL1950 CSA C22.2 No. 950 Case material Aluminum substrate with plastic case Compensated line drops up to 0.5V on 5V models Compensated line drop up to 300mV on 2.9V & 3.3V models 24Vin nominal 48Vin nominal 350kHz typ. Material flammability UL94V-0 18 to 36VDC 36 to 75VDC MTBF 85g (3.0oz) MIL-HDBK-217F Size Reverse voltage protection 1500VDC 1500VDC Weight INPUT SPECIFICATIONS Input voltage range See table 500,000 hours 2.2 x 2.2 x 0.5 inches 55.9 x 55.9 x 12.7 mm (See Note 5) ENVIRONMENTAL SPECIFICATIONS Max. input rise and fall time Start-up time Remote ON/OFF Logic compatibility ON OFF PAGE 138 48V 5V/ms ETS300-132 Thermal performance 30ms typ. CMOS/TTL Open-circuit <1VDC Thermal impedance (See Note 6) Baseplate operating temperature Non-operating -40C to +105C -55C to +105C No air flow, no heatsink No air flow, with heatsink 8.5C/W 7.2C/W Data Sheet (c) Artesyn Technologies(R) 2000 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. DC/DC CONVERTERS | 40W DC/DC 40 Watt Wide input DC/DC converters INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT CURRENT (MAX.) 18-36VDC 3.3V 7A INPUT CURRENT (1) TYPICAL EFFICIENCY 70mA REGULATION LINE (2) LOAD 75% 0.3% MODEL NUMBER (12) (3) 1.0% BXA40-24S3V3-SM BXA40-24S05-M (8) (8) 18-36VDC 5.0V 8A 40mA 81% 0.3% 1.0% 18-36VDC 12.0V 3.33A 60mA 85% 0.3% 1.0% BXA40-24S12-M 18-36VDC 15.0V 2.67A 50mA 85% 0.3% 1.0% BXA40-24S15-M 36-75VDC 2.9V 6.9A 40mA 77% 0.3% 1.0% BXA40-48S2V9-SM (8) 36-75VDC 3.3V 7.0A 40mA 75% 0.3% 1.0% BXA40-48S3V3-SM (8) 36-75VDC 5V 8.0A 30mA 82% 0.3% 1.0% 36-75VDC 12V 3.3A 30mA 87% 0.3% 1.0% BXA40-48S12-M 36-75VDC 15V 2.67 A 30mA 87% 0.3% 1.0% BXA40-48S15-M BXA40-48S05-M (8) Notes 13 An external filter capacitor is necessary for safe operation of the 24V input models. It is also suggested that an external filter capacitor be used on the 48V input models. A 4F (or greater) film capacitor such as: ITW Paktron Capstick series, part number 405K100CS4 4F/100V is recommended, if filtering is not used. See BXA40 Design Note 101. 14 A top mounted heatsink kit is available for the BXA40. The heatsink may be oriented parallel to or perpendicular to the direction of the pins, thus providing optimum flexibility for cooling requirements. The order number for the top mounted heatsink kit with metric screws is `NFC40-HTSK-T'. The order number for the top mounted heatsink kit with imperial screws is `NFC40-HTSK-I'. See Design Note 101 for ambient temperature derating calculations. 1 2 3 4 Nominal line, at no load. Low line to high line at full load. Full load to no-load at nominal line. For conducted noise operation of the BXA40 to VDE0871, VDE0878 and EN55022 level B, see BXA40 Design Note 101. 5 Reverse voltage protection can be implemented by putting a slow blow fuse on the positive input rail. Rate the fuse at 200VDC,1.5A for 48VDC inputs and 100V, 4.5A for 24VDC input units. 6 The maximum operating ambient temperature, without derating depends on internal power dissipation and hence efficiency and cooling method. Download BXA40 Design Note 101 which provides detailed thermal calculations and design-in hints from the Artesyn website. 7 Do not exceed a dv/dt rate of 100V per second at the trim pin input if output current is less than 0.4% lo max. 8 Remote sense is offered as standard on the 2.9V and 3.3V products. The BXA40-24S05 and BXA40-48S05 come with remote sense as an option. Remote sense design is designated by the suffix '-S' e.g. BXA40-48S05SM (for units with metric inserts), BXA40-48S05-S (for units with imperial inserts). For models without remote sense option, pin 5 and pin 6 are absent. 9 Overvoltage protection is 118% on 3.3V output models. 10 For 2.9V output, no short circuit protection above 90C baseplate temp. 11 Transient response, 25% to 100% load, 10% for 2.9V and 3.3V models. 12 Units with the suffix `-M' at the end of the model number are offered as standard with metric threaded inserts (M3). To order units with imperial threaded inserts (4-40 UNC) please remove the suffix `-M' from the model number. These inserts are used for bolting the unit to a PCB and/or fixing heatsinks. EXTERNAL OUTPUT TRIMMING Output can be externally trimmed by 10% using either method shown below. TRIM DOWN RT1 9 OR RT2 9 TRIM UP 1.90 (48.26) 0.15 (3.82) SINGLE OUTPUT 1 + Input 2 - Input 3 Control 4 No Connection 10K TRIMPOT 8 8 PIN CONNECTIONS PIN NUMBER 5 7 7 1.25 (31.76) 0.019 (0.50) 0.60 (15.24) 0.2 (5.08) 3 2 1 1.02 (0.043) Diameter Typ. 5 - Sense (8) 6 + Sense (8) 7 + Output 8 Common 9 Trim Metric (Suffix '-M'): M3 Tap Thru. 4 places or Imperial (No '-M' suffix) 440 UNC (Optional) 1.80 (45.72) 1.90 (48.26) 2.20 0.02 (55.90 0.50) 0.256 (6.50) Diameter Stand-off (4 Places) 9 0.50 (12.70) 8 7 6 0.15 (3.90) International Safety Standard Approvals 0.1 (2.54) 4 0.2 (5.08) 0.05 (1.27) 0.15 (3.82) 0.6 (15.24) 0.8 0.5 (20.32) (12.70) 2.20 0.02 (55.90 0.50) DS_BXA40_20000101.PDF VDE0805/EN60950/IEC950 File No. 14501-3336-7009 Licence No. 6296 0.3 (7.62) 5 BOTTOM VIEW ALL DIMENSIONS IN INCHES (mm) TOLERANCE : 0.004 (0.1) (Unless otherwise specified) UL1950 File No. E174104 CSA C22.2 No. 950 File No. LR41062C Please consult our website for the following items: Design Note http://www.artesyn.com PAGE 139