Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5582UG Multi-Conductor - Residential, Light Commercial and Institutional Applications For more Information please call 1-800-Belden1 General Description: Security & Alarm Cable, Rated-CM, 4-22 AWG solid bare copper conductors with polyolefin insulation, PVC jacket Physical Characteristics (Overall) Conductor AWG: # Conductors AWG Stranding Conductor Material 4 22 Solid BC - Bare Copper Total Number of Conductors: 4 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PP - Polypropylene 0.1524 Outer Shield Outer Shield Material: Outer Shield Material Unshielded Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.381 Overall Cable Overall Cabling Color Code Chart: Color Black Red Yellow Green Overall Nominal Diameter: 3.099 mm Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +75C UL Temperature Rating: 75C Bulk Cable Weight: 19.347 Kg/Km Max. Recommended Pulling Tension: 138.784 N Min. Bend Radius/Minor Axis: 30.480 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM NEC Articles: 800 CEC/C(UL) Specification: CM Page 1 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5582UG Multi-Conductor - Residential, Light Commercial and Institutional Applications CEC/C(UL) Specification: CM EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading CSA Flame Test: FT1 Plenum/Non-Plenum Plenum (Y/N): No Electrical Characteristics (Overall) Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 51.5117 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 2.2 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 5582UG U4FC1000 305 MT 5.443 KG BEIGE U4F 4 #22 PP FRPVC 5582UG U4FC500 152 MT 2.722 KG BEIGE U4F 4 #22 PP FRPVC 5582UG U4FU1000 305 MT 5.897 KG BEIGE U4F 4 #22 PP FRPVC 5582UG 001C500 152 MT 2.722 KG BROWN 4 #22 PP FRPVC 5582UG 008C1000 305 MT 5.443 KG GRAY 4 #22 PP FRPVC 5582UG 008C500 152 MT 2.722 KG GRAY 4 #22 PP FRPVC 5582UG 009C1000 305 MT 5.443 KG WHITE 4 #22 PP FRPVC 5582UG 009C500 152 MT 2.722 KG WHITE 4 #22 PP FRPVC 5582UG 009U1000 305 MT 5.897 KG WHITE 4 #22 PP FRPVC Revision Number: 1 Notes Item Desc Revision Date: 03-11-2013 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide Page 2 of 3 08-21-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 5582UG Multi-Conductor - Residential, Light Commercial and Institutional Applications for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 08-21-2013