When using Zigbee 3.0 install codes the device EUI and install code entered must match the EUI and install code of the desired device.
The EUI is an 8-byte (16-digit number) expressed in hexadecimal format. The install code is 16-byte (32-digit number) expressed in
hexadecimal format. Refer to the following for additional information on creating and flashing Silicon Labs reference designs with Zig-
bee 3.0 installation codes:
•http://community.silabs.com/t5/Mesh-Knowledge-Base/Z3-network-join-with-install-code-derived-link-key/ta-p/191924
•http://www.silabs.com/documents/public/application-notes/AN714-SmartEnergyECCEnabledDeviceSetupProcess.pdf
To enter join mode for the Silicon Labs lighting reference design press S1 ten times rapidly, for the contact sensor press S1 for more
than one second, for the dimmer switch press S3 for more than one second, for the occupancy sensor press S1 for more than one
second, and for the outlet press the front button for more than three seconds. Additional information can be found in the user's guide for
each device. Devices will appear in the list with their name, endpoint, unique node ID, and state. The name shown is determined by the
Zigbee device ID of the endpoint(s) reported by each device and the unique node ID is assigned each time the device joins a Zigbee
network. For a device supporting multiple-endpoints, each endpoint will appear as an individual entry in the device list with correspond-
ing name and endpoint.
If a device is on a network and communicating with the gateway, its state will be labeled as “joined”. A device failing to respond will be
labeled “unresponsive”. To request a device to leave the network, select the “X” next to the device. The device will be labeled "leave
sent" if there is no response from the device. Devices may become unresponsive or indicate leave sent because they are asleep,
turned off, or out of range. When the device wakes, turns on, or comes back into range, the unresponsive device will be labeled as
“joined” and a device labeled “leave sent” will be removed from the device list.
RD-0030-0201: Contact Sensor Reference Design will indicate open/close state, active/alarm state, temperature, and the join/leave-
sent/unresponsive state. The open/close state is sent by the contact sensor immediately upon change of state to indicate whether the
magnet is away (open) or near (closed) the reed switch. The alarm state is sent by the contact sensor immediately upon change of
state when the tamper alarm is activated by pressing button S1 for more than four seconds and then releasing.
RD-0020-0601, RD-0035-0601, RD-0085-0401, and RD-0098-0401: Lighting Demo Board Reference Designs will present the Toggle
Light, Turn On and Turn Off buttons to change the on/off state of the light and indicate the join/leave-sent/unresponsive state. The Tog-
gle Light button sends the ZCL on-off toggle command while the Turn On/Off buttons send the ZCL on-off on and ZCL on-off off com-
mand respectively.
RD-0039-0201: Capacitive Sense Dimmer Switch Reference Design will show the joined/leave sent/unresponsive state.
RD-0078-0201 and RD-0099-0201: Occupancy Sensor Reference Design will indicate occupied or not occupied state, temperature,
and the join/leave-sent/unresponsive state.
RD-0051-0201 and RD-0100-0201: Smart Outlet Reference Design will present Toggle Power, Turn On, and Turn Off buttons to
change the on/off state of the outlet and indicate the join/leave-sent/unresponsive state. The Toggle Power button sends the ZCL on-off
toggle command while the Turn On/Off buttons send the ZCL on-off on and ZCL on-off off command respectively.
Figure 5.4. Attached Devices
The gateway allows the user to create rules to bind one device to another. To create a rule, click [+ Set Rule], choose the desired input
node and output node, and click [Bind]. Multiple rules can be set for both input nodes and output nodes. If two input nodes send a
UG129: Zigbee® Gateway Reference Design User's Guide (RD-0001-0201, RD-0002-0201)
Run the Gateway
silabs.com | Building a more connected world. Rev. 0.7 | 15