www.honeywell.com/sensing/products/di
ML S
ERIES
•
PRESSURE
TRANSDUCER
TECHNICAL SPECIFICATIONS
Sensing and Control
Honeywell
100 Discov ery Way
Acton, MA 01720 USA
T el: (877) 384-1300; Fax: (978) 263-0630
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell
will repair or replace without charge those items it finds defective. The foregoing is Buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of merchantability and fitness for a particular purpose.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
Item # 1121700 M.G. 3/01 Rev. A
RANGES
15, 25, 50 PSIG; 100, 200, 300, 500, 1000, 2000, 3000, 5000 PSIS
6, 10, 16, 25, 40, 60, 100,160, 250 BAR
PHYSICAL
Proof Pressure < 500 psi ≥ 500 psi
2 X rated range 1.5 X rated range
Burst Pressure < 500 psi ≥ 500 psi (30K psi max)
10 X rated range 10 X rated range
Material in Contact 300 series SS,
with Media braze compound
Weight 2.0 oz (57 gm)
ENVIRONMENTAL
Shock 50 g’s peak (5 ms), 100 g’s peak (11 ms)
Vibration Figure 514.2-5, Curve AK, Table 514.2-V
Random Vibration Test (Overall g rms = 20.7 minimum)
ELECTRICAL Ratiometric Voltage Regulated Current
Zero Output 0.5 Vdc 1.0 Vdc 4.0 mA
Full Scale Output* 4.0 Vdc 5.0 Vdc 16 mA
(0.50-4.50 Vdc) (1.0-6.0 Vdc) (4-20 mA)
Excitation 5 Vdc ±250 mV 7-35 Vdc 9.5-35 Vdc
(7.0 V max)
Supply Current 5 mA typical 5 mA typical N/A
(7 mA max) (7 mA max)
Source (nominal) 2.0 mA 2.0 mA N/A
Sink (nominal) 20 µA 20 µA N/A
@ zero output @ zero output
Supply Rejection Ratio 90 db 90 db 90 db
Output Impedance 25 W max. 25 W max. N/A
PERFORMANCE
Response Time < 500 microseconds
EMI/RFI Exceeds CE heavy industrial (30v/m radiated 150kHz-1gHz)
Electrical Packard Metri-Pack™ connector requires
Connection Packard #12065287 mating connector
Accuracy ±0.25% F.S.O. best fit straight line.
Includes: non-linearity, hysteresis, non-repeatability.
Thermal errors not included. 0.5% < 100 PSI **
Total Error Band ±2% Typical (±3% Max.) F.S.O.
Includes: zero offset error, span error, thermal effect on zero
and thermal effect on span, non-linearity, hysteresis, non-repeatability
Compensated Operating and -40° to 105°C
Storage Temperature Range (-40° to 221°F)
* PSIG vented thru vent hole protected by Gortex
®
filter
NOTE: All specifications are measured at 25
°
C (77
°
F) and at rated excitation unless
otherwise specified.
NOTE: Meets IEC-68-2 or MIL-STD 810C.
NOTE: Contact the factory to discuss other pressure ranges.
PIN AND WIRE CODES
DIMENSIONS
xx.xx = inches
(xx.x) = mm
Pins Voltage Current
A + Excitation + Excitation
B Output - Excitation
C Common NC
[40] *
1.58
[19]
0.73 [22]
0.85
1/8-27 NPT or 1/4-18 NPT
1-1/16 [27] HEX
[27]
1.06
[15] **
0.60
a
c
b
Not Intended for
Customer use
* Maximum
** 0.75 [19] for 1/4-18 NPT