S 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS
S\072001\Q1
Single Output to 125A 660 Vac
AC/DC Control
FEATURES/BENEFITS
Industry standard package
Internal snubber (except S60 models)
Designed for all types of loads
AC or DC control available
Excellent thermal performance
Tight zero-cross window for low EMI
High immunity to surges
DESCRIPTION
The Series S single-phase relays are designed for all
types of loads. The design incorporates an SCR or
triac output. The relays utilize optical isolation to protect
the control from load transients . All contain an internal
snubber f or output protection. High current models are
excellent for motor and phase angle control.
APPLICATIONS
Heating control
Motor control
Uninterruptible power supplies
Light dimmers
Industrial and process control
On/Off controls of AC equipment
APPROVALS
S60 models are pending UL recognition. All other
models are UL recognized. UL File Number: E128555.
Part Numbers
Package & Line Switch Output Options3
Chip Type Voltage1Type2Current
S24R12 -22
D25
A40
S48R25 -22
D50
A75
95
125
S60D50
75
95
125
Part Number Example: S48A25-22
Series S
NOTES
1) Line Voltage (nominal): 24 = 240 Vac; 48 = 480 Vac; 60 = 600 Vac
2) Switch Type: R = Random turn-on; D = Zero cross turn-on;
A = AC control, Zero cross turn-on
3) Options: -22 = 24Vac control. Available on D type 240Vac, 25 and 40A
models and D type 480Vac, 25, 50, 125A models
MECHANICAL SPECIFICATION
TOLERANCES: ±.01 (0.3) WEIGHT: 3.18 oz. (90g)
1~ 2~
4- 3+
1.1 (28)
Ø.19 (Ø4.7)
1. 7 ( 43.2)
1.87 (47.6)
.26 (7.5)
.2 (5.1)
1 (25.4)
1.75 (44.5)
M4
M3
2.29 (58.2)
1.06 (27)
.77 (19.6)
.9 (22.8)
(
±
0.5)
1.02 (25.8)
(
±
.02)
Figure 1 — S relays, 12–95 A;
dimensions in inches (mm)
125A model uses larger M5 output screw terminals
4-
3+
-
+
1
2
* 1-2 can be changed
* SSR must be mounted on a heat sink
Line Protection
LOAD
Line Voltage
Control
Figure 2 — S relays
TYPICAL APPLICATION
© 2002 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S 3
S\072001\Q1
Series S
INPUT (CONTROL) SPECIFICATION
Input Type Min Max Units
Control Range
S24 R 3 30 Vdc
D430Vdc
S48 R 4 30 Vdc
D530Vdc
S60 D 7 30 Vdc
SxxA A 90 240 Vac/Vdc
Sxxxxx-22 A 17 80 Vac/Vdc
Input Current Range
SR/D330mA
SA38mA
Sxxxxx-22 A 5.6 26 mA
Must Turn-Off V oltage
SR/D 1Vdc
S24 A 15 Vac
S48 A 1 Vac
Sxxxxx-22 3 Vac
Input Resistance (Typical)
SR/D 1000 Ohms
SA 30,000 Ohms
Sxxxxx-22 3000 Ohms
Re verse Voltage Protection
SR/D 30V
SA NA
Control Voltage (V)
Input Current (mA)
4
6
8
10
14
16
20
18
22
24
26
28
12
2
0210 12 140468 1618 26 28 3020 22 24
CONTROL CHARACTERISTICS
Figure 3a — S48R, S48D and S60D relays
CONTROL CHARACTERISTICS
Control Voltage (V)
Input Current (mA)
4
6
8
10
14
16
20
18
22
24
26
28
30
12
2
0210 12 140468 1618 26 28 3020 22 24
Figure 3b — S24D/R relays
Control Voltage (V)
Input Current (mA)
001020304050607080
5
10
15
20
25
30
Figure 3c — S24A and S48A relays
Control Voltage (V)
Input Current (mA)
4
6
8
2
020 100 120 1400406080 160180 200 220 240
Figure 3d — Sxxxxx-22 relays
S 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS
S\072001\Q1
OUTPUT (LOAD) SPECIFICATION
Input Type Min Max Units
Operating Range
S24 12 280 Vrms
S48 24 520 Vrms
S60 24 660 Vrms
Peak V oltage
S24 600 Vpeak
S48 1200 Vpeak
S60 1600 Vpeak
Load Current Range (Resistive)
12A output current .005 12 Arms
25A output current .005 25 Arms
40A output current .005 40 Arms
50A output current .005 50 Arms
75A output current .005 75 Arms
95A output current .005 95 Arms
125A output current .005 125 Arms
Inductive Load Current
12A output current 2.5 Arms
25A output current 5 Arms
40A output current 9 Arms
50A output current 12 Arms
75A output current 16 Arms
95A output current 20 Arms
125A output current 30 Arms
Capacitive Load Current
S60D50 13 Arms
S60D75 24 Arms
S60D90 36 Arms
S60D125 48 Arms
Maximum Surge Current Rating (Non-Repetitive)
12A output current 120 A
S24, 25A output current 240 A
S24R25 250 A
S48, 25A output current 230 A
40A output current 350 A
50A output current 550 A
75A output current 1000 A
95A output current 1500 A
Series S
Maximum Surge Current Rating (Non-Repetitive)
(Continued)
125A output current 2000 A
On-State V oltage Drop
12A output current 1.3 V
25A output current 1.2 V
40A output current 1.4 V
50A output current 1.4 V
75A output current 1.35 V
S60D75 1.3 V
95A output current 1.3 V
S60D90 1.15 V
125A output current 1.3 V
S60D125 1.1 V
Zero Cross Window (Typical)
SR NA
SD/A ±12 Vac
Off-State Leakage Current (60Hz)
S24 3 mA
S48 D/A 3 mA
S48 R 2.5 mA
S60 A 1 mA
Turn-On Time (60 Hz)
SR 0.1 ms
SD 8.3 ms
SA 24.9 ms
Turn-Off Time (60 Hz)
SR/D 8.3 ms
SA 24.9 ms
Off-State dv/dt
All relays 500 V/µs
Maximum di/dt (Non-Repetitive)
All relays 50 A/µs
OUTPUT (LOAD) SPECIFICATION (Continued)
Input Type Min Max Units
© 2002 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S 5
S\072001\Q1
Series S
Operating Frequency
All relays 0.1 440 Hz
I2t for match fusing (<8.3ms)
12A output current 72 A2S
S24R25 312 A2S
S24D/S24A 25A output current 288 A2S
S48 25A output current 265 A2S
40A output current 612 A2S
50A output current 1500 A2S
75A output current 5000 A2S
95A output current 11000 A2S
125A output current 20000 A2S
ENVIRONMENTAL SPECIFICATION
Min Max Units
Operating Temper ature –40 100 °C
Storage Temper ature –40 100 °C
Input-Output Isolation 4000 Vr ms
Output-Case Isolation
12A output current 2500 Vrms
25A output current 2500 Vrms
40A output current, R 2500 Vrms
40A output current, D 3300 Vrms
40A output current, A 3300 Vrms
50A output current 3300 Vrms
75A output current 3300 Vrms
95A output current 3300 Vrms
125A output current 3300 Vrms
OUTPUT (LOAD) SPECIFICATION (Continued)
Input Type Min Max Units
1010.10.01
50
100
150
0
t(s)
Apeak
Non-repetitive
Repetitive with initial T
j
= 70°C
11010.10.01
0
50
100
150
200
250
0
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
1100.10.01
0
100
200
300
400
0
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
1100.10
0
200
400
600
0
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
t(s)
Apeak
1010.10.01
500
1000
1500
0
Non-repetitive
Repetitive with initial T
j
= 70°C
11010.10.01
0
500
1000
1500
2000
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
SURGE CURRENT (continued)
Figure 4a — 12A output current
Figure 4b — 25A output current
Figure 4c — 40A output current
Figure 4d — 50A output current
Figure 4e — 75A output current
Figure 4g — 125A output current
SURGE CURRENT
Figure 4f — 95A output current
t(s)
A
peak
Repetitive with initial T
j
= 70°C
Non-repetitive
11010.10.01
0
500
1000
1500
0
S 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2002 TELEDYNE RELAYS
S\072001\Q1
Series S
T case
max (°C)
100
95
90
85
80
75
Pd (watts)
1.1
°
C/W
1.6
°
C/W
6
°
C/W
4
°
C/W
Full on state
50% duty cycle
0
2
4
6
8
10
12
14
16
18
20
01 2 34 5 67 891011 12 0 10 20 30 40 50 60 70 80 90 100 110 120
RMS Load Current (A) Ambient Temperature (°C)
2.2
°
C/W
Pd (watts)
RMS Load Current (A) Ambient Temperature (°C)
T case
max (°C)
100
90
80
70
0.95
°
C/W 0.75
°
C/W
1.6
°
C/W
1.1
°
C/W
2.2
°
C/W
Full on state
50% duty cycle
0
0
5
10
15
20
25
30
35
40
24681012 14 16 18 20 22 24 26 0 10 20 30 40 50 60 70 80 90 100 110 120
6
°
C/W
2.2
°
C/W
1.1
°
C/W
0.95
°
C/W
0.75
°
C/W 0.55
°
C/W
1.6
°
C/W
6
°
C/W
Full on state
50% duty cycle
0
0
5
10
15
20
25
30
35
40
45
50
55
60
24681012 14 16 18 20 22 24 26 3028 32 34 36 38 40 0 10 20 30 40 50 60 70 80 90 100 110 120
65
90
100
80
70
75
85
95
T case
max (°C)
Pd (watts)
RMS Load Current (A) Ambient Temperature (°C)
Pd (watts)
RMS Load Current (A) Ambient Temperature (°C)
051015 20 25 30 35 40 45 50 55 60
0
0
10
20
30
40
50
60
70
80
90
100
0
0.3
°
C/W0.55
°
C/W
1.6
°
C/W
6
°
C/W
0.95
°
C/W
Full on state
50% duty cycle
010 203040 50607080 90100 110 120
70
80
90
100
75
85
95
T case
max (°C)
0.75
°
C/W
1.1
°
C/W
2.2
°
C/W
Pd (watts)
RMS Load Current (A) Ambient Temperature (°C)
70
80
90
100
75
85
95
T case
max (°C)
1002030405060708090
0
10
20
30
40
50
60
70
80
90
100
110
120
130
0102030405060708090100 110 120
2.2
°
C/W
1.1
°
C/W
0.3
°
C/W
1.6
°
C/W
6
°
C/W
0.55
°
C/W
0.75
°
C/W
0.95
°
C/W
Full on state
50% duty cycle
Pd (watts)
RMS Load Current (A) Ambient Temperature (°C)
2.2
°
C/W
1.1
°
C/W
0.95
°
C/W
0.3
°
C/W
0.75
°
C/W
1.6
°
C/W
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
01020304050607080901001101200102030405060708090100110
Full on state
50% duty cycle
70
80
90
100
75
85
95
T case
max (°C)
6
°
C/W
Pd (watts)
RMS Load Current (A) Ambient Temperature (°C)
2.2
°
C/W
0.3
°
C/W
0.55
°
C/W
1.6
°
C/W
1.1
°
C/W
0.95
°
C/W
0.75
°
C/W
6
°
C/W
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
0102030405060708090100 110 1200102030405060708090100 110 120 130 140 150
Full on state
50% duty cycle
65
80
90
100
70
T case
max (°C)
THERMAL CHARACTERISTICS
Figure 5a — 12A output current
Figure 5b — 25A output current
Figure 5c — 40A output current
Figure 5d — 50A output current
Figure 5e — 75A output current
Figure 5f — 95A output current
Figure 5g — 125A output current
NOTES:
1. Electrical specifications measured at 25°C unless otherwise
specified.
2. For 800Hz applications, contact factory.
3. For additional/custom options, contact factory.