© 2002 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com S 5
S\072001\Q1
Series S
Operating Frequency
All relays 0.1 440 Hz
I2t for match fusing (<8.3ms)
12A output current 72 A2S
S24R25 312 A2S
S24D/S24A 25A output current 288 A2S
S48 25A output current 265 A2S
40A output current 612 A2S
50A output current 1500 A2S
75A output current 5000 A2S
95A output current 11000 A2S
125A output current 20000 A2S
ENVIRONMENTAL SPECIFICATION
Min Max Units
Operating Temper ature –40 100 °C
Storage Temper ature –40 100 °C
Input-Output Isolation 4000 Vr ms
Output-Case Isolation
12A output current 2500 Vrms
25A output current 2500 Vrms
40A output current, R 2500 Vrms
40A output current, D 3300 Vrms
40A output current, A 3300 Vrms
50A output current 3300 Vrms
75A output current 3300 Vrms
95A output current 3300 Vrms
125A output current 3300 Vrms
OUTPUT (LOAD) SPECIFICATION (Continued)
Input Type Min Max Units
1010.10.01
50
100
150
0
t(s)
Apeak
Non-repetitive
Repetitive with initial T
j
= 70°C
11010.10.01
0
50
100
150
200
250
0
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
1100.10.01
0
100
200
300
400
0
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
1100.10
0
200
400
600
0
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
t(s)
Apeak
1010.10.01
500
1000
1500
0
Non-repetitive
Repetitive with initial T
j
= 70°C
11010.10.01
0
500
1000
1500
2000
t(s)
A
peak
Non-repetitive
Repetitive with initial T
j
= 70°C
SURGE CURRENT (continued)
Figure 4a — 12A output current
Figure 4b — 25A output current
Figure 4c — 40A output current
Figure 4d — 50A output current
Figure 4e — 75A output current
Figure 4g — 125A output current
SURGE CURRENT
Figure 4f — 95A output current
t(s)
A
peak
Repetitive with initial T
j
= 70°C
Non-repetitive
11010.10.01
0
500
1000
1500
0