1
www.power-one.com
2/12.2000
• Rugged electrical and mechanical design
• Output 1 regulated, outputs 2 and 3 tracking
• Operating ambient temperature range
–25...71°C with convection cooling
H Series 50 Watt DC-DC Converters
Wide input voltage ranges up to 60 V DC
1, 2 or 3 outputs up to 48 V DC
4 kA DC I/O electric strengh test voltage
Selection chart
Output 1 Output 2 Output 3 Input voltage Type Options
U
o nom
I
o nom
U
o nom
I
o nom
U
o nom
I
o nom
U
i
[V DC] [A] [V DC] [A] [V DC] [A] [V DC]
5.1 8 - - - - 8...15 12H1001-2R -7, D, V
5.1 8 - - - - 14...30 24H1001-2R -7, D, V
5.1 8 - - - - 28...60 48H1001-2R -7, D, V
12 4 - - - - 8...15 12H1301-2R -7, D
12 4 - - - - 14...30 24H1301-2R -7, D
12 4 - - - - 28...60 48H1301-2R -7, D
15 3.4 - - - - 8...15 12H1501-2R -7, D
15 3.4 - - - - 14...30 24H1501-2R -7, D
15 3.4 - - - - 28...60 48H1501-2R -7, D
24 2 - - - - 8...15 12H1601-2R -7, D
24 2 - - - - 14...30 24H1601-2R -7, D
24 2 - - - - 28...60 48H1601-2R -7, D
48 1 - - - - 9...15 12H1901-2R -7, D
48 1 - - - - 18...30 24H1901-2R -7, D
48 1 - - - - 36...60 48H1901-2R -7, D
12 2 12 2 - - 8...15 12H2320-2 -7, D
12 2 12 2 - - 14...30 24H2320-2 -7, D
12 2 12 2 - - 28...60 48H2320-2 -7, D
15 1.7 15 1.7 - - 8...15 12H2540-2 -7, D
15 1.7 15 1.7 - - 14...30 24H2540-2 -7, D
15 1.7 15 1.7 - - 28...60 48H2540-2 -7, D
5.1 5 12 0.7 12 0.7 8...15 12H3020-2 -7, D, V
5.1 5 12 0.7 12 0.7 14...30 24H3020-2 -7, D, V
5.1 5 12 0.7 12 0.7 28...60 48H3020-2 -7, D, V
5.1 5 15 0.6 15 0.6 8...15 12H3040-2 -7, D, V
5.1 5 15 0.6 15 0.6 14...30 24H3040-2 -7, D, V
5.1 5 15 0.6 15 0.6 28...60 48H3040-2 -7, D, V
LGA