DRR-DTH/DRT-DTH Features and Benefits
DIMENSIONS (in) mm
Notes 1) For details on electrical specifications,contact Hamlin.
2) Contact rating-Product of the switching voltage and current should never exceed the
wattage rating.
Contact Hamlin for additional load/life information.
3) Operate/Release Time-per EIA/NARM RS421A,diode suppressed coil.
4) Pull in Range-Contact Hamlin for tolerances available within this range.
5) Rating Sensitivity-The value at which contact ratings and operating characteristics are
determined.Derating may be required below this value.
6) Storage Temperature-Long time exposure at elevated temperature may degrade
solderability of the leads.
7) Contact resistance measured at 36 Vdc, 100 ma, switched wet.
Switch Type DRR-DTH DRT-DTH *
Contact Form CC
ELECTRICAL RATINGS
Contact Rating (2) Watt - max. 30 50
Voltage Switching Vdc - max. 500 500
Breakdown Vdc - min. 1200 1000
Current Switching A - max. 0.5 1.5
Carry A - max. 3.0 2.0
Resistance Contact,Initial Ω- max. 0.125 0.500 (7)
Insulation Ω- min. 109109
Capacitance Contact pF - typ. 2.0 2.0
Temperature Operating °C -20 to +125 -20 to +125
Storage (6) °C -65 to +125 -65 to +125
OPERATING CHARACTERISTICS
Operate Time (3) ms - max. 4.5 5.5
Release Time (3) ms - max. 7.0 8.0
Shock 11ms 1⁄2sine wave G - max. 10 10
Vibration 50-2000 Hertz G - max. 15 15
Resonant Frequency Hz - typ. 2750 2750
MAGNETIC CHARACTERISTICS
Pull-In Range (4) Ampere Turns 50-80 50-80
Rating Sensitivity (5) Ampere Turns 60 60
Test Coil L4988 L4988
Features
•Changeover switch with
39.67mm x 5.53mm (1.562” x
0.21”) glass envelope
•Capable of carrying up to 3 Amps
•Maximum contact rating up to
50 Watts
•Minimum voltage breakdown
1200 Vdc
•109Ohms insulation resistance
•Available sensitivity range
50-80 AT
Benefits
•Hermetically sealed switch contacts
are not eff ected by and have no effect
on their external environment
•Can be used as changeov er or
normally closed contact
•Capable of switching European
mains voltage
•Low,stable contact resistance
•Zero operating power required for
contact closure
•Fit and forget durability
Applications
•Security
•Limit switching
•Industrial safety applications
•White goods applications
•Automotive applications
INFORMATION PROVIDED ON THIS DATA SHEET IS PROVIDED FOR INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED UPON AS BEING ACCURATE FOR ANY
PARTICULAR PURPOSE. Product performance may be affected by the application to which the product is applied. Upon request, HAMLIN will assist purchasers by providing information
specific to any particular application. HAMLIN disclaims any and all liability whatsoever for any purchaser’s reliance upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.
USA Tel: +1 920 648 3000 • Fax: +1 920 648 3001 • Email: sales.us@hamlin.com
UK Tel: +44 (0)1379 649700 • Fax: +44 (0)1379 649702 • Email: sales.uk@hamlin.com
Germany Tel: +49 (0) 6142 923920 • Fax: +49 (0) 6142 923921 • Email: sales.de@hamlin.com
France Tel: +33 (0) 1 6047 3000 • Fax: +33 (0) 1 6015 9136 • Email: sales.fr@hamlin.com
ISSUE No: 3 DATE: 28/09/0
www.hamlin.com