© 2015 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-33M/CR-33M Page 1
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
ELECTRICAL CHARACTERISTICS
Form Factor SPDT,
break before make
Frequency Range
CCR-33M
CR-33M DC–3 GHz
DC–3 GHz
Characteristic Impedance 75 Ohms
Operate Time 10 ms (max.)
Release Time 10 ms (max.)
Actuation Voltage Available 12 15 24 28 V
Actuation Current, max. @ ambient 200 250 120 90 mA
ENVIRONMENTAL AND PHYSICAL CHARACTERISTICS
Operating Temperature
Commercial Model, CCR-33M
Elite Model, CR-33M 40°C to 65°C
55°C to 85°C
Vibration (MIL-STD-202 Method 214,
Condition D, non-operating) 10 g’s RMS
Shock (MIL-STD-202 Method 213,
Condition D, non-operating) 500 g’s
Standard Actuator Life
Actuator Life w/ Additional Features 5,000,000 cycles
1,000,000 cycles
Connector Type mini-SMB
Humidity (Moisture Seal) Available
Weight 1.65 oz. (46.78g) (max.)
TYPICAL PERFORMANCE CHARACTERISTICS
Frequency DC–1 GHz 1–2 GHz 2–3 GHz
Insertion Loss, dB,
typical. 0.1 0.2 0.2
Isolation, dB, typical. 70 65 65
VSWR , typical. 1.1:1 1.3:1 1.3:1
PART NUMBERING SYSTEM
Connector
M: mini-SMB Female Actuator Voltage
1: 28 Vdc Failsafe
2: 15 Vdc Failsafe
3: 12 Vdc Failsafe
4: 24 Vdc Failsafe
Actuator Type
0: Standard Contacts
C: Indicator Contacts
**SEE PARTS LIST ON PAGE 7
Options
T: TTL Drivers with Diodes
D: Transient Suppression
Diodes
N: Narrow Body
M: Moisture Seal
S: 9 Pin D-Sub Connector
Actuator Voltage
CCR-33 M 1 C - T **
Series
Connectors Actuator Type
Options
For other options, contact factory.
PART NUMBER DESCRIPTION
CCR-33M Commercial Failsafe SPDT, DC-3GHz
CR-33M Elite Failsafe SPDT, DC-3GHz
The CCR-33M/CR-33M is a broadband, SPDT, electromechanical, coaxial switch designed to switch
a microwave signal from a common input to either of two outputs. The characteristic impedance is 75
Ohms. The small switches incorporate mini-SMB connectors.
The CCR-33M/CR-33M series switch is offered with a failsafe actuator. This design is compatible with
the two most common mounting hole patterns. The CCR-33M/CR-33M series switch is interchangeable
with a variety of switches.
For maximum limits, please see charts on page 3-5
Available with
USB & Ethernet
Control!
Click here
MMA SERIES
CCR-33M/CR-33M Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2015 TELEDYNE COAX SWITCHES
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch COAX SWITCHES
SCHEMATICS AND MECHANICAL OUTLINE
9 PIN D-SUB PINOUT FOR FAILSAFE SPDT
OPTIONS
Pin
No. Basic Indicators TTL Indicators &
TTL
1+ +
2- -
3 Common Common
411
5
6VswVsw
7A A
8B B
9C C
1
6
“-S OPTION9-PIN D-SUB CONNECTOR (EXAMPLE: CCR-33M10-S)
TRUTH TABLE (with TTL option)
Logic
Input RF Path Indicator
(if applicable)
1IN
to 1 IN
to 2 AB
0On Off C0
1Off
On 0C
H = 1.30 MAX. STD MODEL
H = 1.80 MAX. TTL MODEL
Standard
Width Body
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
Indicators Analog
TTL
Optional Narrow
Width Body H = 1.30 MAX. STD MODEL
H = 1.80 MAX. TTL MODEL
2X SOLDER TERMINALS
SOLDER WIRE MAXIMUM
TEMP 250ºC FOR NO
MORE THAN 5 SEC
© 2015 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-33M/CR-33M Page 3
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF INSERTION LOSS PERFORMANCE CURVES
-1
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
0 0.2 0.4 0.6 0.8 1
Insertion Loss (dB)
Frequency (GHz)
Insertion Loss ( DC-1 GHz )
-1
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
1 1.2 1.4 1.6 1.8 2
Insertion Loss (dB)
Frequency (GHz)
Insertion Loss ( 1-2 GHz )
-1
-0.9
-0.8
-0.7
-0.6
-0.5
-0.4
-0.3
-0.2
-0.1
0
2 2.2 2.4 2.6 2.8 3
Insertion Loss (dB)
Frequency (GHz)
Insertion Loss ( 2-3 GHz )
TYPICAL
MAXIMUM TEST LIMIT
CCR-33M/CR-33M Page 4 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2015 TELEDYNE COAX SWITCHES
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch COAX SWITCHES
TYPICAL NARROWBAND RF ISOLATION PERFORMANCE CURVES
TYPICAL
MAXIMUM TEST LIMIT
-140
-120
-100
-80
-60
-40
-20
0
0 0.2 0.4 0.6 0.8 1
Isolation (dB)
Frequency (GHz)
Isolation ( DC-1 GHz )
-140
-120
-100
-80
-60
-40
-20
0
1 1.2 1.4 1.6 1.8 2
Isolation (dB)
Frequency (GHz)
Isolation ( 1-2 GHz )
-140
-120
-100
-80
-60
-40
-20
0
20
2 2.2 2.4 2.6 2.8 3
Isolation (dB)
Frequency (GHz)
Isolation ( 2-3 GHz )
© 2015 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-33M/CR-33M Page 5
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
TYPICAL NARROWBAND RF VSWR PERFORMANCE CURVES
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
0 0.2 0.4 0.6 0.8 1
VSWR
Frequency (GHz)
VSWR ( DC-1 GHz )
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
1 1.2 1.4 1.6 1.8 2
VSWR
Frequency (GHz)
VSWR ( 1-2 GHz )
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
2 2.2 2.4 2.6 2.8 3
VSWR
Frequency (GHz)
VSWR ( 2-3 GHz )
TYPICAL
MAXIMUM TEST LIMIT
CCR-33M/CR-33M Page 6 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2015 TELEDYNE COAX SWITCHES
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch COAX SWITCHES
Actuator
An actuator is the electromechanical mechanism that
transfers the RF contacts from one position to another upon
DC command.
Arc Suppression Diode
A diode is connected in parallel with the coil. This diode
limits t he “revers e EMF spike” gener ated wh en the c oi l de -
energizes to 0.7 volts. The diode cathode is connected to
the po sitive side of the c oil and the ano de is connected to
the negative side.
Date Code
All sw itch es are m ar ked with ei ther a uni que se ri al numbe r
or a date code. Date codes are in accordance with MIL-
STD-1285 Paragraph 5.2.5 and consist of four digits.
The rst two digits de ne the year and the last two digits
de ne the week of the year (YYWW). Thus, 1032 identi es
switches that passed through nal inspection during the
32nd week of 2010.
Failsafe
A failsafe switch reverts to the default or failsafe position
when actuating voltage is removed. This is realized by a
return spring within the drive mechanism. This type of switch
require s th e continuous ap plicati on of operating voltage to
select and hold any position. (Multi-position switches are
normally open with no voltage applied).
Indicator
Indicators tell the system which position the switch is in.
Other names for indicators are telemetry contacts or tellback
circuit. Indicators are usually a set of internally mounted DC
co nt ac t s linked to th e ac tu ato r. They c an b e wi re d to di git a l
input lines, status lights, or interlocks. Unless otherwise
speci ed, the ma ximum indicator contact rating is 30 Vdc,
50 mA, or 1.5 Watts into a resistive load.
Isolation
Isolation is the measure of the power level at the output
co nnecto r of an unco nnecte d RF chann el as referenc ed to
the power at the input co nnector. It is speci ed in dB be low
the input power level.
SPDT Switch
A single-pole double-throw, bi-directional switch that can
be used as having on e input and t wo out puts o r t wo inputs
and one output.
Switching Time
Switching time is the total interval beginning with the arrival
of the leading edge of the command pulse at the switch DC
input and ending w it h t h e comp let i on of t h e swi tc h t rans fer,
including contact bounce. It consists of three parts: (1)
inductive delay in the coil, (2) transfer time of the physical
movement of the contacts, and (3) the bounce time of the
RF contacts.
TTL Switch Driver Option
As a special option, switch drivers can be provided for both
failsafe and latching switches, which are compatible with
industry-standard low-power Schottky TTL circuits.
Performance Parameters vs Frequency
Generally speaking, the RF performance of coaxial switches
is frequency dependent. With increasing f requency, VSWR
and insertion loss increase while isolation decreases. All
data sheets specify these three parameters as “worst case”
at the highest operating frequency. If the switch is to be
used over a narrow frequency band, better performance
can be achieved.
Actuator Current vs Temperature
The resistance of the actuator coil varies as a function of
temperature. There is an inverse relationship between the
oper ating temperatur e of the switch and t he actuator dri ve
current. For switches operating at 28 VDC, the approximate
actuato r drive cur rent at temperat ure, T, can be c alculated
using the equation:
Magnetic Sensitivity
An electro-mechanical switch can be sensitive to ferrous
materials and external magnetic elds. Neighboring ferrous
materials should be permitted no closer than 0.5 inches and
adjacent external magnetic elds should be limited to a ux
density of less than 5 Gauss.
GLOSSARY
IA
[1 + .00385 (T-20)]
Where:
IT= Actuator current at temperature, T
IA = Room temperature actuator current –
see data sheet
T= Temperature of interest in °C
IT =
Carrier
Frequency 1 Carrier
Frequency 2 PIM 3rd Order
Frequency PIM 5th
Order Fre-
quency
870 MHz 893 MHz 847 MHz 824 MHz
3rd Order
Intermodulation 5th Order
Intermodulation
SPDT 91 dBm –110 dBm
134 dBc 153 dBc
SPECIAL FEATURE
Switching High-Power or Highly Sensitive Signals
Ensure the most linear response with the best galvanically
matched contact system in the industry. Extremely low
passive intermodulation is standard on all of our switches.
© 2015 TELEDYNE RELAYS (800) 284-7007 • www.teledynecoax.com CCR-33M/CR-33M Page 7
CCR-33M\CR-33M\092015\Q3
Series CCR-33M/CR-33M
Miniature DC3 GHz
Failsafe SPDT Coaxial Switch
COAX SWITCHES
FAILSAFE CCR-33M/CR-33M PART NUMBER LIST
* X = 1 (28Vdc), 2 (15Vdc), 3 (12Vdc) and 4 (24Vdc)
PART NO.PART NO.PART NO.
1CCR-33MXC 43 CCR-33MX0-TMS 85 CR-33MX0-NM
2CCR-33MXC-D 44 CCR-33MX0-TN 86 CR-33MX0-NMS
3CCR-33MXC-DM 45 CCR-33MX0-TNM 87 CR-33MX0-NS
4CCR-33MXC-DMS 46 CCR-33MX0-TNMS 88 CR-33MX0-S
5CCR-33MXC-DN 47 CCR-33MX0-TNS 89 CR-33MX0-T
6CCR-33MXC-DNM 48 CCR-33MX0-TS 90 CR-33MX0-TM
7CCR-33MXC-DNMS 49 CR-33MXC 91 CR-33MX0-TMS
8CCR-33MXC-DNS 50 CR-33MXC-D 92 CR-33MX0-TN
9CCR-33MXC-DS 51 CR-33MXC-DM 93 CR-33MX0-TNM
10 CCR-33MXC-M 52 CR-33MXC-DMS 94 CR-33MX0-TNMS
11 CCR-33MXC-MS 53 CR-33MXC-DN 95 CR-33MX0-TNS
12 CCR-33MXC-N 54 CR-33MXC-DNM 96 CR-33MX0-TS
13 CCR-33MXC-NM 55 CR-33MXC-DNMS
14 CCR-33MXC-NMS 56 CR-33MXC-DNS
15 CCR-33MXC-NS 57 CR-33MXC-DS
16 CCR-33MXC-S 58 CR-33MXC-M
17 CCR-33MXC-T 59 CR-33MXC-MS
18 CCR-33MXC-TM 60 CR-33MXC-N
19 CCR-33MXC-TMS 61 CR-33MXC-NM
20 CCR-33MXC-TN 62 CR-33MXC-NMS
21 CCR-33MXC-TNM 63 CR-33MXC-NS
22 CCR-33MXC-TNMS 64 CR-33MXC-S
23 CCR-33MXC-TNS 65 CR-33MXC-T
24 CCR-33MXC-TS 66 CR-33MXC-TM
25 CCR-33MX0 67 CR-33MXC-TMS
26 CCR-33MX0-D 68 CR-33MXC-TN
27 CCR-33MX0-DM 69 CR-33MXC-TNM
28 CCR-33MX0-DMS 70 CR-33MXC-TNMS
29 CCR-33MX0-DN 71 CR-33MXC-TNS
30 CCR-33MX0-DNM 72 CR-33MXC-TS
31 CCR-33MX0-DNMS 73 CR-33MX0
32 CCR-33MX0-DNS 74 CR-33MX0-D
33 CCR-33MX0-DS 75 CR-33MX0-DM
34 CCR-33MX0-M 76 CR-33MX0-DMS
35 CCR-33MX0-MS 77 CR-33MX0-DN
36 CCR-33MX0-N 78 CR-33MX0-DNM
37 CCR-33MX0-NM 79 CR-33MX0-DNMS
38 CCR-33MX0-NMS 80 CR-33MX0-DNS
39 CCR-33MX0-NS 81 CR-33MX0-DS
40 CCR-33MX0-S 82 CR-33MX0-M
41 CCR-33MX0-T 83 CR-33MX0-MS
42 CCR-33MX0-TM 84 CR-33MX0-N
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Teledyne Relays:
CCR-33M8O CCR-33M1O CCR-33M3C CCR-33M8O-R CCR-33K6OM CCR-33M80-R CCR-33M80 CCR-
33K60M