Special Features
Electrical Specs
25 Watts
AA25N
• Ideal for telecom/networking
applications
• High efficiency
• Unencapsulated 2.0” x 2.0” x 0.50” package.
• Integral heat spreader available
• 100°C Baseplate temperature
• Enable (on/off)
• Thermal protection
• 350kHz Switching frequency
• Under voltage lockout
Input
Input range 18-36 Vdc (24 Vdc nominal)
36 - 75Vdc (48Vdc nominal)
Input capacitance 2mF typical
Input reverse voltage
protection Fuse recommended
Input surge voltage 100V for 100mS (048L)
50V for 100mS (024L)
36V for 100mS (012L)
Input reflected ripple <10mA (P-P) See Note 2
Undervoltage lockout Vin<32V (-048L ONLY)
Efficiency 82% typical
Output
Voltage tolerance Main Output ±1.0%
Aux Output ±3.0%
Dual Output ±2.0%
Line regulation Main Output ±0.1%
Aux Output ±0.5%
Dual Output ±0.2%
Load regulation Main Output ±0.75%
Aux Output ±3.0%
Dual Output ±0.5%
(10% to 100% load) Note 6.
Noise/ripple 50mV P-P, Singles
100mVp-p, Dual , Triple
Short circuit protection Continuous power cycle
Overvoltage protection 120% of V0, Typ
Transient response 2% Vo typ; recovery <500msec typ
(25% step load change to within 1%Vo)
Temperature coefficient ±0.2%/°C
Switching frequency 350kHz
Control
Enable on =2.5 to 5.5Vdc or open circuit
off = 0 to 0.8Vdc
Ref. to -Vin. TTL compatible
Input current (enable OFF) <10ma
Output trim Single output models
Thermal shutdown 110°C Baseplate temperature (typ)
Auto reset
Isolation
I/O isolation 1500Vdc
Isolation resistance 15 x 108 ohms
Environmental
Total Power: 25 Watts
Input Voltages: 24V or 48V
No. of Outputs: Single, Dual, Triple
Operation case temperature range: -40°C to
+100°C
Storage temperature: -40°C to +125°C
Humidity: 5% to 100%
Safety
UL UL1950
CAN CAN22.2-950
TUV EN60950
Astec Conventional Power
America’s (USA): 1-888-41-ASTEC Europe (UK): 44 (1384) 842-211 Asia (HK): 852-2437-9662
70
W9959_02_DCDC_001-073_73 2/8/02 3:56 PM Page 70