Pin Indicating Type FNA
Dual-Element, Time-Delay
1/10–30 Amps
Form No. FNA
Page 1 of 1
BIF Doc #2029
Bussmann®
11-7-01 SB98107
0.343"
(blown)
0.063"
1.5"
(50.031)
(not blown)
0.406"
(50.004)
0.343"
(blown)
0.063"
1.5"
.817"
.406" .406"
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select-
ed, it should be tested by the user in all possible applications.
Dimensional Data
1
10
100
1,000
CURRENT IN AMPERES
100
10
1
.1
.01
TIME IN SECONDS
AMPERE
RATING
1
15
20
Electrical Ratings (Catalog Symbol and Amperes)
250 Volts AC IR* 125 Volts AC IR 125 Volts AC IR 125 Volts AC
FNA-1/10 FNA-1 FNA-3 FNA-9
FNA-1/8 FNA-1-1/8 FNA-3-2/10 FNA-10
FNA-15/100 FNA-1-1/4 FNA-3-1/2 FNA-12
FNA-2/10 FNA-1-4/10 FNA-4 FNA-15
FNA-1/4 FNA-1-1/2 FNA-4-1/2 32 Volts A C†
FNA-3/10 FNA-1-6/10 FNA-5 FNA-20
FNA-4/10 FNA-1-8/10 FNA-5-6/10 FNA-25
FNA-1/2 FNA-2 FNA-6 FNA-30
FNA-6/10 FNA-2-1/4 FNA-6-1/4
FNA-3/4 FNA-2-1/2 FNA-7
FNA-8/10 FNA-2-8/10 FNA-8
*Interrupting rating of 10,000A at 125V AC.
†Interrupting rating of 1,000A at 32V.
Time-Current Characteristic Curves–Average Melt
IR
35A IR
10,000A IR
10,000A
IR
10,000A
IR
1kA
Use in power electronic circuits in which there are high
inrush currents and fuse openings must be quickly apparent.
Has silver-plated pin for positive, electrical signal activation.
FNAs larger than 10 amperes have dual-tube construction.
Mount in Buss fuseblock 3839 for signal indication.
Mount in HPF-C panel-mounted fuseholder or BM series
fuseblocks for visual indication.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000V AC, 75-1500V DC). Refer to BIF document #8002 or contact
Bussmann Application Engineering at 314-527-1270 for more information.
12-30A
Dual Tube Construction
CATALOG SYMBOL: FNA (5AG) ⁄Ω¡º-10A
DU AL-ELEMENT, TIME-DELAY
1/10 TO 30 AMPERES
U.L. LISTED:
⁄Ω¡º-°Ω¡ºA, IR 35A@ 250V
IR 10kA@ 125V
1-15A, IR 10kA@ 125V
(GUIDE # JDYX, FILE # E19180)
CSA CERTIFIED
0-10/125V A
(CLASS 1422-01, FILE # 53787)
Carton Quantity and Weight
Ampere Carton Weight
Ratings Qty Lbs. Kg.
0–10 100 1.5 0.650
12–30 100 3.0 1.36