I/O MODULE G4 DIGITAL DC INPUT DATA SHEET Form 253-990215 Description page 1/4 Part Number Description G4IDC5 G4 DC Input 10-32 VDC, 5 VDC Logic G4IDC5B G4 DC Input 4-16 VDC, 5 VDC Logic High Speed G4 DC Input 2.5-28 VDC, 5 VDC Logic Opto 22's G4 DC input modules are used to detect G4IDC5G G4 DC Input 35-60 VDC, 5 VDC Logic on/off DC voltage levels. Each module provides up to G4IDC5K G4 DC Input 2.5-16 VDC, 5 VDC Logic Very High Speed 4,000 Vrms of optical-isolation between field inputs and G4IDC5MA G4 DC Input 10-32 VDC, 5 VDC Logic With Manual/Auto Switch the logic output of the circuit. All DC input modules except the G4IDC5K and G4IDC15 G4 DC Input 10-32 VDC, 15 VDC Logic G4IDC5D are designed with filtering on the input and a G4IDC24 G4 DC Input 10-32 VDC, 24 VDC Logic hysteresis amplifier, providing high noise rejection and transient-free, "clean" switching. The G4IDC5K is a fast-switching module used to detect signals produced by photoelectric switches and TTL devices. The low-cost G4IDC5D is used for data acquisition. The G4IDC5MA is a special module featuring a manual-on/manual-off/automatic switch, ideal for diagnostic testing of control applications. Typical applications for DC input modules include sensing the presence or absence of voltage, and sensing contact closure from sources such as proximity switches, limit switches, selector switches, push buttons, photoelectric switches, and TTL-compatible devices. G4IDC5D Features * * * * * * * * 4,000 Vrms optical isolation Built-in LED status indicator Small footprint design, reducing mounting space by approximately 50 percent Built-in filtering for transient suppression and noise rejection Operating temperature: -30 C to 70 C UL recognized, CSA certified, CE approved Passes NEMA Showering Arc Test (ICS 2-230) Meets IEEE Surge Withstand Specification (IEEE-472) Opto 22 * 43044 Business Park Drive * Temecula, CA 92590 * Phone: (909) 695-3000 * (800) 321-OPTO * Fax: (909) 695-3095 * Internet: www.opto22.com Inside Sales: (800) 452-OPTO * Product Support: (800) TEK-OPTO * (909) 695-3080 * Fax: (909) 695-3017 * E-mail: support@opto22.com * FaxBack: (800) 474-OPTO Dimension and specifications are subject to change. All products and/or company names throughout this data sheet are generally trademarks or registered trademarks of their respective companies. I/O MODULE G4 DIGITAL DC INPUT DATA SHEET page 2/4 Form 253-990215 Specifications Input voltage range Units G4IDC5 G4IDC5B G4IDC5D G4IDC5G VDC VAC 10-32 12-32 4-16 4-16 2.5-28 --- 35-60 35-60 --- Higher speed High speed --- Key feature Input current at maximum line mA 25 45 30 6 Isolation input-to-output Vrms 4,000 4,000 4,000 4,000 Turn-on time ms 5 0.05 1 10 Turn-off time ms 5 .1 1.5 10 Input allowed for off-state mA, V 1, 3 .7, 1 .2, 1 .7, 7 Nominal output supply voltage VDC 5 5 5 5 Output supply voltage range VDC 4.5-6 4.5-6 4.5-6 4.5-6 mA 12 12 12 12 Input resistance (R1 in schematic) 1.5K 300 900 10K Control resistance (RC in schematic) 220 220 470 220 V @ 50 mA .4 .4 .4 .4 mA 50 50 50 50 Output leakage with no input A @ 30 VDC 100 100 10 100 Transistor V breakdown 30 30 30 30 C C -30 to +70 -30 to +85 -30 to +70 -30 to +85 -30 to +70 -30 to +85 -30 to +70 -30 to +85 Output supply current at nominal logic voltage Output voltage drop Output current (sinking) Temperature: Operating Storage Opto 22 * 43044 Business Park Drive * Temecula, CA 92590 * Phone: (909) 695-3000 * (800) 321-OPTO * Fax: (909) 695-3095 * Internet: www.opto22.com Inside Sales: (800) 452-OPTO * Product Support: (800) TEK-OPTO * (909) 695-3080 * Fax: (909) 695-3017 * E-mail: support@opto22.com * FaxBack: (800) 474-OPTO I/O MODULE G4 DIGITAL DC INPUT DATA SHEET page 3/4 Form 253-990215 Specifications (CONT.) Units G4IDC5K G4IDC5MA G4IDC15 G4IDC24 VDC VAC 2.5-16 --- 10-32 12-32 10-32 12-32 10-32 12-32 Highest speed Diagnostic switch --- --- mA 30 25 25 25 Vrms 4,000 4,000 4,000 4,000 Turn-on time ms .025* 5 5 5 Turn-off time ms .025* 5 5 5 mA, V .2, 1 1, 3 1, 3 1, 3 Nominal ouput supply voltage VDC 5 5 15 24 Output supply voltage range VDC 4.5-6 4.5-6 12-18 20-30 mA 12 12 15 18 Input resistance (R1 in schematic) 500 1.5K 1.5K 1.5K Control resistance (Rc in schematic) 220 220 1K 2.2K V @ 50 mA .4 .4 .4 .4 mA 50 50 50 50 Output leakage with no input A @ 30 VDC 100 100 100 100 Transistor V breakdown 30 30 30 30 C C -30 to +70 -30 to +85 -30 to +70 -30 to +85 -30 to +70 -30 to +85 -30 to +70 -30 to +85 Input voltage range Key feature Input current at maximum line Isolation input-to-output Input allowed for off-state Output supply current at nominal logic voltage Output voltage drop Output current (sinking) Temperature: *At 5Vp-p square wave input, 50% duty cycle. Opto 22 * 43044 Business Park Drive * Temecula, CA 92590 * Phone: (909) 695-3000 * (800) 321-OPTO * Fax: (909) 695-3095 * Internet: www.opto22.com Inside Sales: (800) 452-OPTO * Product Support: (800) TEK-OPTO * (909) 695-3080 * Fax: (909) 695-3017 * E-mail: support@opto22.com * FaxBack: (800) 474-OPTO I/O MODULE G4 DIGITAL DC INPUT DATA SHEET page 4/4 Form 253-990215 Dimensions Schematics Opto 22 * 43044 Business Park Drive * Temecula, CA 92590 * Phone: (909) 695-3000 * (800) 321-OPTO * Fax: (909) 695-3095 * Internet: www.opto22.com Inside Sales: (800) 452-OPTO * Product Support: (800) TEK-OPTO * (909) 695-3080 * Fax: (909) 695-3017 * E-mail: support@opto22.com * FaxBack: (800) 474-OPTO Dimension and specifications are subject to change. All products and/or company names throughout this data sheet are generally trademarks or registered trademarks of their respective companies.