SPECIFICATION
35W Single Output Switching Power Supply LRS-35 series
File Name:LRS-35-SPEC 2015-06-16
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION Note.4
LOAD REGULATION
Note.5
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1000ms, 30ms/230VAC 2000ms,30ms/115VAC at full load
30ms/230VAC 12ms/115VAC at full load
85 ~ 264VAC 120 ~ 373VDC
47 ~ 63Hz
86% 86% 88% 89%
0.7A/115VAC 0.42A/230VAC
COLD START 45A/230VAC
<0.75mA / 240VAC
110 ~ 150% rated output power
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
-30 ~ +70℃(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
763.6K hrs min. MIL-HDBK-217F (25 )℃
0.23Kg ; 60pcs/14.8Kg/0.88CUFT
99*82*30mm (L*W*H)
12V 15V 24V 48V
3A 2.4A 1.5A 0.8A
0 ~ 3A 0 ~ 2.4A 0 ~ 1.5A 0 ~ 0.8A
36W 36W 36W 38.4W
120mVp-p 120mVp-p 150mVp-p 200mVp-p
±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5%
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE Note.3
PROTECTION
ENVIRONMENT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
88%
36V
1A
0 ~ 1A
36W
200mVp-p
±1.0%
±0.5%
±0.5%
5V
7A
0 ~ 7A
35W
80mVp-p
±2.0%
±0.5%
±1.0%
82%
SAFETY STANDARDS UL60950-1, TUV EN60950-1, EN60335-1, EN61558-1 2 16 approved/- - ,CCC GB4943
Protection type : Shut down o/p voltage, re-power on to recover
5.75 ~ 6.9V 13.8 ~ 16.2V 18.75 ~ 21.75V 28.8 ~ 33.6V 41.4 ~ 48.6V 55.2 ~ 64.8V
Compliance to EN55022 (CISPR22), GB9254 Class B, EN55014, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A
SAFETY &
EMC
(Note 9)
EMC IMMUNITY
EMC EMISSION
10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 43.2 ~ 52.8V
32.4 ~ 39.6V
4.5 ~ 5.5V
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up
time.
7. 5V when the load factor 0~50%, the switching power less is reduced by burst operation, which will cause ripple and ripple noise to go
beyond the specifications.
8. The ambient temperature derating of 5 /1000m is needed for operating altitude greater than 2000m(6500ft).
℃
9. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed
that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power
supplies. (as available on http://www.meanwell.com)
LRS-35-5 LRS-35-12 LRS-35-15 LRS-35-24 LRS-35-36 LRS-35-48