869 FIBER SENSORS Digital Mark Sensor Amplifier Built-in LX-100 SERIES Related Information General terms and conditions............ F-17 Glossary of terms........................ P.1359~ Sensor selection guide...................P.831~ General precautions...................... P.1405 LASER SENSORS PHOTOELECTRIC SENSORS Conforming to EMC Directive MICRO PHOTOELECTRIC SENSORS Recognition AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic-electric-works.net/sunx PNP output type available Timer Automatic sensitivity setting STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Introduction of the 3 LED mark sensor Can detect any mark! Coaxial reflective optics and a sharp 1 x 5 mm 0.039 x 0.197 in spot enable high precision sensing. Stable detection of marks is possible. Newly developed 4-digit digital display The 4-digit digital display enables numerical sensing control and minute settings. Operation panel R*G*B light emitting elements all in one 3 large buttons that click into position making operation easy. To detect any marking, this unit is blue equipped with red, green and blue light emitting emittingelements elementsallallinin LED light one. Highest in the industry 12-bit A/D converter A resolution of 1/4,000 is realized to enable high precision mark sensing. Total reflection High precision coaxial mirror reflective optical system Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Panasonicunique SUNX's Electriccoaxial Works SUNX's reflective optics coaxial technology ensures unique reflective optics very accurate sensing. is made technology ensuresThe veryunit accurate with a scratchproof sensing. The unit is glass madelens. with a scratchproof glass lens. Half mirror Receiving element Glass lens Protection IP67 Image schematic Water Detection Other Products LX-100 FZ-10 The 3 colors of the R*G*B LEDs are optimally selected according to the color combination. With the LX-100's Mark mode, the built-in "Automatic optimal LED selection function" automatically selects the LED for the largest contrast (S / N ratio) between the mark and base (non-mark area) to ensure optimal sensing. For more stable detection, the sensor makes selection according to the contrast and not according to the reflected light variation between the mark and base (non-mark area). The example on the right deals with reflected light on packing film. Great figures are indicated for the blue LED's light amount ratio and, for even more stable sensing, the blue LED effectuates this mark sensing. Example: A packing film Mark Light amount = ratio Base 6 : 8 Reflective light Small / Slim Object Detection Obstacle Detection Reflective light Ultrasonic Automatic optimal LED selection function Reflective light Color Mark Detection Hot Melt Glue Detection Washing the machines and production line with water will not affect the sensor thanks to its waterproof construction. Spot size 1 x 5 mm 0.039 x 0.197 in approx. Mark Light amount = ratio Base 8 : 4 Optimal Mark Light amount = ratio Base 4 : 1 Digital Mark Sensor LX-100 SERIES Two detection modes can be selected from to suit the application Mark mode Ultra high-speed response This sensing mode automatically selects a single color from the 3 R*G*B LEDs to achieve an ultra quick 45 s response time. The automatic optimal LED selection function automatically selects the LED that is most suitable for the sensing. This function is perfect for ultra quick sensing. RED 870 FIBER SENSORS Automatic selection of the optimal LED LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS GREEN BLUE AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Color mode High precision discrimination SIMPLE WIRE-SAVING UNITS All 3 R*G*B LEDs light up and high precision mark color discrimination occurs using the R*G*B reflective light ratio. This function enables effective detection of films with patterns around the area of the mark. WIRE-SAVING SYSTEMS The color around letters is detected as a mark. MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS Predetermined colors are detected as marks. MACHINE VISION SYSTEMS UV CURING SYSTEMS * You can select the mark mode or color mode through key operation. High precision mark color discrimination The color mode on the LX-100 series utilizes all 3 R*G*B LEDs to determine the R*G*B ratio of the mark color. The built-in 12-bit A/D converter enables high precision 1/4,000-resolution judgments. The figure below is a graphic description of this process. 1. 1-level teaching for this mark 2. R*G*B ratio calculated 3. Precise determination of consistency of the spot color (R*G*B ratio) a Inconsistent c Inconsistent c b b R: 15 G: 10 B: 5 Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Small / Slim Object Detection Obstacle Detection Other Products LX-100 Mark Even similar colors are accurately determined using the R*G*B ratio. Wafer Detection Ultrasonic Reflective light a b Consistent Selection Guide FZ-10 13 : 10 : 5 15 : 10 : 5 15 : 10 : 6 871 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Digital Mark Sensor LX-100 SERIES Its digital display makes settings easy! Numerical control of the settings is possible The 4-digit digital display enables easy verification of received light from marks and base (non-mark area). Also, the threshold value can be controlled numerically enabling setting indication easily. Displaying the direct code enables settings verification. This function is handy for remote maintenance. MODE indicator 4-digit digital display amount and ( Light-receiving setting values are displayed. ) MODE indicator Operation indicator LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES MODE key (PRO mode: CANCEL key) OFF key (PRO mode: ENTER key) ON key (PRO mode: SELECT key) Even beginners can quickly master MODE NAVI operation The sensor's basic operations are represented by 6 indicators (MODE NAVI). The user can check what mode the sensor is presently in with a quick glance making operation simple. This is the sensing mode. The digital display shows the light-receiving amount (mark mode) and the color consistency (color mode). RUN COLOR TEACH TIMER ADJ PRO This mode enables a mark mode / color mode selection. ENDOSCOPE LASER MARKERS This is the threshold value setting (teaching) mode. PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS This is the threshold fine-adjustment mode. Wafer Detection Liquid Leak Detection Liquid Level Detection The sensing status, displayed numerically, can be verified at a glance. Also, the sensor settings for each type of packing film can be digitally indicated. * Example of sensor setting indication Selected LED: Green LED Threshold value: 1850 Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 Selected LED: Blue LED Threshold value: 1600 Direct codes enable settings verification at a glance The settings for the LX-100 series sensors are displayed using a 4-digit direct code. Direct codes enable easy setting verification and maintenance by phone. Water Detection Color Mark Detection Hot Melt Glue Detection This mode enables the setting of various functions such as key lock and timer period. Sensing status digitally controllable Selected LED: Red LED Threshold value: 600 Selection Guide Timer type selection mode. What is the direct code? The direct code is 0004. At present, the sensor is operating with a mark at 2300 and base at 860. Digital Mark Sensor Direct code table (D-Code) When in RUN mode, press the MODE key for at least 2 sec. to display the direct code. (Remove your finger from the MODE key and the direct code will disappear.) The sensor setting modes can be verified by a 4-digit code (D-Code). The table below shows a list of all available codes. 1st digit 2nd digit Display Sensing mode (light source color) Operation mode (Note 1) Sensing (Note 2) FINE L-ON COARSE Mark mode (green) FINE D-ON COARSE FINE L-ON COARSE Mark mode (blue) FINE D-ON COARSE FINE L-ON COARSE Mark mode (red) FINE D-ON COARSE FINE Consistent-ON COARSE Color mode FINE Inconsistent-ON COARSE LX-100 SERIES 3rd digit Display Display mode ECO mode (Note 4) Turn mode (Note 5) Display Key lock OFF Full lock OFF ON Standard (All operations disabled) OFF ON ON RUN teaching OFF OFF (Teaching only enabled) ON Percent display OFF RUN adjust (Note 3) ON ON Threshold value adjustment only enabled ( ) 4th digit Timer mode Display Timer period 1 ms non 2 ms OFF-delay 5 ms ON-delay 10 ms non 20 ms OFF-delay 50 ms ON-delay 100 ms non 200 ms OFF-delay 500 ms ON-delay FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS Notes: 1) In Mark mode, L-ON / D-ON is automatically set in the sensor. For example, with 2-level teaching, press the ON key at the targeted mark and press the OFF key at the base (non-mark area). When doing so, the operator does not have to consider L-ON / D-ON. 2) Sensing accuracy can be set to either FINE (standard) or COARSE. 3) The percent display is only enabled in mark mode. 4) ECO mode is a function that reduces power consumption by turning off the digital display in the event that no button operations are made for a predetermined time (approx. 10 sec. or more) in RUN mode. Press any button to turn the digital display on again. 5) The turn mode is a function that reverses the digital display making it easily to be viewed in the event that the sensor installation renders the display up-side-down. * Default setting: D-code = " ". Super simple teaching SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE Press the ON button at the targeted mark. External teaching possible Here is an example of the most basic setting method "2-level teaching". Teaching is possible through external input using an operation panel or touch panel even on hard-to-reach color mark sensors located inside an equipment. Also, models can be interchanged easily. Mode selection Press MODE key and select TEACH mode. Mark mode 2-level teaching and full-auto teaching possible Teaching 872 1 Align the spot on the mark and press the ON key. 2 Align the spot onto the base (non-mark area) and press the OFF key. * The 1 2 order can be reversed. Color mode 1-level teaching possible LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Display showing complete settings Sensing Selection Guide Teaching complete. The optimal LED is automatically selected and the sensor automatically returns to RUN mode. Wafer Detection Liquid Leak Detection Liquid Level Detection Other teaching methods * Full-auto teaching: In Mark mode, teaching is effective without stopping the sensing object. * 1-level teaching: In Color mode, the color detected is aligned by the spot and teaching is effective. Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Compact design for significant space savings Key lock function High precision sensing and multiple functions are all packed in a compact W57 x D24 x H38 mm W2.244 x D0.945 x H1.496 in body. Cable and plug-in connector types are available depending on the equipment used. These sensors can mm be easily introduced 38 1.496 in to existing facilities. The key lock function enables input operation control that prevents mistaken changes in the sensor settings. Other detailed settings include "RUN adjust", allowing threshold value adjustment only, and "RUN teaching", allowing teaching operation only. If the sensor is set to "RUN adjust" or "RUN teaching", adjustment and teaching are possible having the sensor remained in RUN mode. 24 mm 0.945 in 57 mm 2.244 in Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 873 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS ORDER GUIDE Sensors Mating cable is not supplied with the plug-in connector type. Please order it separately. Type Appearance Cable type LASER SENSORS Output LX-101 NPN open-collector transistor LX-101-P PNP open-collector transistor LX-101-Z NPN open-collector transistor LX-101-P-Z PNP open-collector transistor Type Model No. Description CN-24B-C2 Length: 2 m 6.562 ft CN-24B-C5 Length: 5 m 16.404 ft CN-24BL-C2 Length: 2 m 6.562 ft CN-24BL-C5 Length: 5 m 16.404 ft 0.34 mm2 4-core cabtyre cable, with connector on one end Cable outer diameter: o5 mm o0.197 in Elbow FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Wafer Detection OPTIONS Type Sensor mounting bracket Model No. MS-LX-1 MS-LX-2 Description Mounting bracket made for LX-100 series applicable for various kinds of installations Sensor mounting bracket * MS-LX-1 * MS-LX-2 Liquid Leak Detection Water Detection Color Mark Detection Hot Melt Glue Detection Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 o14 mm o0.551 in 43.5 mm 1.713 in o5 mm o0.197 in o5 mm o0.197 in o14 mm o0.551 in 29 mm 1.142 in Liquid Level Detection Ultrasonic * CN-24BL-C2 * CN-24BL-C5 31 mm 1.220 in PLC / TERMINALS ENERGY CONSUMPTION VISUALIZATION COMPONENTS Mating cables for plug-in connector type sensor * CN-24B-C2 * CN-24B-C5 Straight LASER MARKERS HUMAN MACHINE INTERFACES Sensing range Mating cables for plug-in connector type sensor Mating cable is not supplied with the plug-in connector type sensor. Please order it separately. STATIC CONTROL DEVICES ENDOSCOPE Model No. 10 3 mm 0.394 0.118 in WIRE-SAVING SYSTEMS MEASUREMENT SENSORS LX-100 SERIES Plug-in connector type FIBER SENSORS Digital Mark Sensor Two M4 (length 28 mm 1.102 in) screws with washers are attached. Two M4 (length 30 mm 1.181 in) screws with washers are attached. Digital Mark Sensor LX-100 SERIES SPECIFICATIONS Model No. Type Item FIBER SENSORS Cable type Plug-in connector type NPN output LX-101 LX-101-Z PNP output LX-101-P LX-101-P-Z Sensing range Spot size 10 3 mm 0.394 0.118 in 1 x 5 mm 0.039 x 0.197 in (at 10 mm 0.394 in setting distance) Supply voltage Current consumption Output 1 (OUT) 12 to 24 V DC 10 % Ripple P-P 10 % or less Normal mode: 750 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) NPN open-collector transistor * Maximum sink current: 50 mA * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 1.5 V or less (at 50 mA sink current) PNP open-collector transistor * Maximum source current: 50 mA * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.5 V or less (at 50 mA source current) Short-circuit protection Output operation Output 2 (OUT) Short-circuit protection Output operation Response time Teaching input Digital display Sensitivity setting NPN open-collector transistor * Maximum sink current: 50 mA * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 1.5 V or less (at 50 mA sink current) PNP open-collector transistor * Maximum source current: 50 mA * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.5 V or less (at 50 mA source current) - Incorporated - Inverted operation of the output 1 - Environmental resistance Ambient humidity Ambient illuminance Voltage withstandability Vibration resistance Shock resistance Emitting element Material Cable Cable extension Weight Accessory PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS Mark mode: 45 s or less, Color mode: 150 s or less NPN non-contact input * Signal condition: High... +5 V to +V, or open Low... 0 to +2 V (source current: 0.5 mA or less) * Input impedance: 10 k approx. LASER SENSORS WIRE-SAVING SYSTEMS Mark mode: Light-ON / Dark-ON (Auto-setting on teaching), Color mode: Consistent-ON / Inconsistent-ON (Setting on teaching) PNP non-contact input * Signal condition: High... +4 V to +V (sink current: 3 mA or less) Low... 0 to +0.6 V, or open * Input impedance: 10 k approx. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS 4-digit red LED display Mark mode: 2-level teaching / Full-auto teaching, Color mode: 1-level teaching Incorporated Selection Guide Incorporated with variable ON-delay / OFF-delay timer, switchable either effective or ineffective (Timer period: 1 to 500 ms, 9 levels variable) Wafer Detection IP67 (IEC) Liquid Leak Detection Protection Ambient temperature NPN open-collector transistor * Maximum sink current: 100 mA * Applied voltage: 30 V DC or less (between output and 0 V) * Residual voltage: 1.5 V or less (at 100 mA sink current) PNP open-collector transistor * Maximum source current: 100 mA * Applied voltage: 30 V DC or less (between output and +V) * Residual voltage: 1.5 V or less (at 100 mA source current) Incorporated Fine sensitivity adjustment function Timer function 874 -10 to +55 C +14 to +131 F (No dew condensation or icing allowed), Storage: -20 to +70 C -4 to +158 F 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure 10 to 500 Hz frequency, 3.0 mm 0.118 in amplitude (max. 20 G) in X, Y and Z directions for two hours each 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions for three times each Combined Red / Green / Blue LEDs (Peak emission wavelength: 640 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil) Enclosure: PBT, Display cover: Polycarbonate, Operation buttons: Silicone rubber, Lens: Glass, Lens holder: Aluminum (Note 2) Extension up to total 100 m 328.084 ft is possible with 0.3 mm , or more, cable. 2 Net weight: 120 g approx., Gross weight: 180 g approx. Water Detection Color Mark Detection Incandescent light: 3,000 x at the light-receiving face 0.34 mm2 5-core cabtyre cable, 2 m 6.562 ft long Liquid Level Detection Net weight: 55 g approx., Gross weight: 120 g approx. M4 (length 30 mm 1.181 in) screw with washers: 2 pcs. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 C +73.4 F. 2) Mating cable is not supplied with the plug-in connector type. Please order it separately. Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 875 Digital Mark Sensor I/O CIRCUIT AND WIRING DIAGRAMS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS LX-101(-Z) D1 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS LASER MARKERS ZD2 ZD1 10 k D2 +5 V Internal circuit Color code of cable type / mating cable for plug-in connector type 2 Terminal No. of plug-in connector type (Brown) +V 10 k D2 Load (Black) Output 1 Load (White) Output 2 (Note 2) 50 mA max. (Note 1) + 50 mA max. (Note 1) 3 - 12 to 24 V DC 10 % (Pink) Teaching input (Blue) 0 V Tr2 3 Internal circuit *1 (Black) Output 1 50 mA max. (Note 1) (White) Output 2 (Note 2) Load Load (Blue) 0 V Users' circuit +V or Non-voltage contact or PNP transistor * Teaching input High: 5 V to +V, or open Low: 0 to +2 V(source current: 0.5 mA or less) Teaching is carried out at the Low. or 0V Symbols ... D1, D2 : Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : NPN output transistor * Teaching input High: +4 V to +V (sink current: 3 mA or less) Low: 0 to +0.6 V, or open Teaching is carried out at the High. Symbols ... D1, D2 : Reverse supply polarity protection diode ZD1, ZD2: Surge absorption zener diode Tr1, Tr2 : PNP output transistor Connector pin layout of plug-in connector type Connector pin No. Description 1 +V 2 Teaching input 3 0V 4 Output SPOT SIZE CHARACTERISTICS (TYPICAL) (Unit: mm in) Spot size (Note 2) Setting distance L (Note 1) Width (W) Length (D) 7 0.276 2.0 0.079 5.5 0.217 8 0.315 1.7 0.067 5.5 0.217 Liquid Level Detection 9 0.354 1.2 0.047 5.3 0.209 Water Detection 10 0.394 1.0 0.039 5.0 0.197 11 0.433 1.3 0.051 5.0 0.197 12 0.472 1.5 0.059 5.0 0.197 13 0.512 2.0 0.079 5.0 0.197 Selection Guide Wafer Detection W Liquid Leak Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 12 to 24 V DC 10 % *1 Non-voltage contact or NPN transistor FA COMPONENTS Hot Melt Glue Detection - *1 ENERGY CONSUMPTION VISUALIZATION COMPONENTS Color Mark Detection + Notes: 1) The current of the plug-in connector type LX-101-P-Z is 100 mA max. 2) The output 2 is not incorporated to the plug-in connector type LX-101-P-Z. HUMAN MACHINE INTERFACES UV CURING SYSTEMS (Pink) Teaching input 50 mA max. (Note 1) 4 D1 Users' circuit 2 (Brown) +V ZD2 Tr1 *1 PLC / TERMINALS MACHINE VISION SYSTEMS ZD1 0V 1 Color code of cable type / mating cable for plug-in connector type Notes: 1) The current of the plug-in connector type LX-101-Z is 100 mA max. 2) The output 2 is not incorporated to the plug-in connector type LX-101-Z. MEASUREMENT SENSORS ENDOSCOPE 4 Tr2 WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES 1 Tr1 PNP output type I/O circuit diagram Terminal No. of plug-in connector type INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS LX-101-P(-Z) NPN output type I/O circuit diagram Sensor circuit PHOTOELECTRIC SENSORS Sensor circuit FIBER SENSORS LASER SENSORS LX-100 SERIES L D Notes: 1) S etting distance "L" represents the distance from the lens surface to the sensing object. 2) Examples only meant for use as a guideline. Digital Mark Sensor PRECAUTIONS FOR PROPER USE * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. Mounting * Care must be taken regarding the sensor mounting direction with respect to the object's direction of movement. Do not make the sensor detect an object in this direction because it may cause unstable operation. Mark and base Mark and base * The tightening torque should be 0.8 N*m or less. Sensing glossy object * Objects with a glossy surface have a large amount of specular reflection particles that may destabilize sensing. In such a case, by slightly tilting the sensor's beam axis, this specular reflection can be reduced rendering sensing more stable. * If the surface of the sensing object has a shine, mount the sensor inclining approx. 10 to 15 degrees against the sensing object. 10 to 15 Wiring * Make sure to carry out wiring in the power supply off condition. * Take care that wrong wiring will damage the sensor. * Verify that the supply voltage variation is within the rating. * Take care that if a voltage exceeding the rated range is applied, or if an AC power supply is directly connected, the sensor may get burnt or damaged. * In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual ground. * If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. * Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. * Take care that short-circuit of the load or wrong wiring may burn or damage the sensor. * Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. * Extension up to total 100 m is possible with 0.3 mm2, or more, cable. However, in order to reduce noise, make the wiring as short as possible. LX-100 SERIES 876 Refer to General precautions. Others * Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. * Take care that the sensor is not directly exposed to fluorescent light from a rapid-starter lamp or a high frequency light device or sunlight etc., as it may affect the sensing performance. * Do not touch the lens of the sensor by hand directly. If the lens becomes dirty, wipe it off with a soft cloth gently. * When the inside lens is steamed up, unscrew the lens to get rid of the condensation. * These sensors are only for indoor use. * Do not use this sensor in places having excessive vapor, dust, etc., or where it may come in direct contact with water, or corrosive gas. * Take care that the product does not come in contact with water, oil, grease, or organic solvents, such as, thinner, etc. * Make sure that stress by forcible bend or pulling with 76 N, or more, force is not applied to the sensor cable joint. * This sensor cannot be used in an environment containing inflammable or explosive gases. * Never disassemble or modify the sensor. FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 877 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Digital Mark Sensor LIST OF PROMODE SETTING ITEMS * Before performing teaching or each detail setting, perform the setting of either mark mode or color mode with mark / color mode setting of NAVI mode. AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10 PROmode * For selecting a setting item, press 'ON key'. For confirming each selected setting item, press 'OFF / ENTER key'. After confirming setting, the digital display flashes. For canceling setting, press 'MODE key'. NAVImode RUN Run OFF At mark mode setting: Indicates the absolute value of emitting amount. It is possible to indicate the relative value (percent value) against threshold value. At color mode setting: Indicates color matching degree with relative value. Press Sensing setting Sets the sensing level (hysteresis.) TEACH SELECT Sensing level: Fine (20ms) Teaching Adjust At mark mode setting: Allows fine adjustment of the threshold value. At color mode setting: Allows adjustment of sensing tolerance value. Sensing level: Coarse (50ms) (100ms) (200ms) (500ms) (10ms) (5ms) (2ms) (1ms) Sets timer setting period by 9-steps. At mark mode setting: Sets the threshold value by '2-level teaching' or 'full-auto teaching'. At color mode setting: Sets the threshold value by '1-level teaching'. ADJ OFF Press ENTER Timer setting Press Key lock setting Set full key lock. Selects key lock function. Set key lock except for RUN adjust mode.(RUN adjust) OFF Press ENTER Set key lock except for RUN teaching mode. (RUN teaching) Display setting Selects display method of digital desplay. Mark mode setting: Displays incident light intesity Color mode setting: Displays color coincidence Mark mode setting: Displays relative value (percentage) Color mode setting: Displays color coincidence Eco setting COLOR Sets ON / OFF of eco mode. Mark / Color mode setting Sets mark mode or color mode. TIMER Changes display direction of digital display. Configures operation of the timer. PRO Eco setting: OFF Eco setting: ON Not invert the display. Invert the display. Display inverting mode setting Timer operation setting Reset setting PRO Allows various detailed settings to be configured. Selection Guide LX-100 SERIES Resets to factory setting. Press Press Not reset the settings. Reset the settings. Digital Mark Sensor DIMENSIONS (Unit: mm in) LX-101LX-101-P 24 0.945 1.5 0.059 OPE. Sensor RUN TEACH ADJ MODE ON SELECT TEACH 5 0.197 FIBER SENSORS LX-101-ZLX-101-P-Z LASER SENSORS 24 0.945 OFF 1.5 0.059 RUN TEACH ADJ OPE. ENTER 57 2.244 47 1.850 Sensor PHOTOELECTRIC SENSORS COLOR TIMER PRO MODE ON CANCEL SELECT TEACH MICRO PHOTOELECTRIC SENSORS OFF ENTER 71.5 2.815 57 2.244 47 1.850 5 0.197 o14.4 o0.567 9.4 0.370 35 25 1.378 0.984 35 25 1.378 0.984 5 0.197 3 0.118 2-o4.5 o0.177 mounting holes o22 (o0.866 ) 15 0.591 MS-LX-1 Sensor mounting bracket (Optional) 4-R2 R0.079 39 1.535 27 1.063 15 0.591 28 1.102 ( o22 o0.866 15 0.591 R2 30.4 R0.079 1.197 21 0.827 25 0.984 6 0.236 9 0.354 47 1.850 57 2.244 72 2.835 Material: Stainless steel (SUS) Two M4 (length 28 mm 1.102 in) screws with washers are attached. 28 1.102 41 1.614 3 0.118 3-M5 x 0.8 0.031 27.2 1.071 PRESSURE / FLOW SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE 60 2.362 15 0.591 3-R2 R0.079 ENERGY CONSUMPTION VISUALIZATION COMPONENTS 47 57 1.850 2.244 4 0.157 4-M4 x 0.7 0.028 6 0.236 FA COMPONENTS MACHINE VISION SYSTEMS R2 R0.079 25 0.984 PLC / TERMINALS HUMAN MACHINE INTERFACES 2-M4 x 0.7 0.028 57.2 2.252 2-R5 10 R0.197 0.394 LASER MARKERS R4.7 R0.185 45 40 1.772 30 1.575 1.181 15 0.591 25 0.984 LIGHT CURTAINS 2-M5 x 0.8 0.031 2-R5 R0.197 5 0.197 80 3.150 R2 R0.079 4 0.157 2-R5 R0.197 5 0.197 2-o4.5 o0.177 mounting holes Sensor mounting bracket (Optional) 20 0.787 2-R4.7 R0.185 57 47 2.244 1.850 ) MS-LX-2 3 0.118 AREA SENSORS INDUCTIVE PROXIMITY SENSORS M12 5 0.197 3 0.118 878 The CAD data in the dimensions can be downloaded from our website. COLOR TIMER PRO CANCEL LX-100 SERIES 5 5 0.197 0.197 UV CURING SYSTEMS Material: Stainless steel (SUS) Two M4 (length 30 mm 1.181 in) screws with washers are attached. Selection Guide Wafer Detection Liquid Leak Detection Liquid Level Detection Water Detection Color Mark Detection Hot Melt Glue Detection Ultrasonic Small / Slim Object Detection Obstacle Detection Other Products LX-100 FZ-10