Zelio Plug-In Relays TM RUM universal range Catalog 2014 Contents ZelioTM Plug-In Relays RUM universal relays bb Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 bb Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 bb References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 bb Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 bb Wiring diagrams. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 bb Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 3 4 ZelioTM Plug-In Relays Introduction RUM universal relays Introduction of product range 6 The RUM universal relay product range includes: 1 10 A relays with 2 and 3 C/O contacts, and cylindrical or quick-connect (Faston type) pins. All of these relays have the same dimensions. 2 Sockets with mixed or separate contact terminals. 3 Protection modules (diode, RC circuit or varistor) or 1 timer module, common to all RUM sockets. 4 Metal maintaining clamp for all RUM sockets. 5 2-pole bus jumper that can be used on sockets with separate contact terminals in order to simplify cabling when creating an equipotential link between the coil terminals. 6 Clip-in legends for the sockets. 2 1 4 5 3 6 Relay description 1 2 1 Spring return pushbutton for testing the contacts (green: Vdc coil; red: Vac coil). 2 Mechanical "relay status" indicator. 3 Removable lock-down door enables continuous engagement of the contacts for test or maintenance purposes.(1). 4 Optional bipolar LED indicating the relay status. 5 Removable ID tag for relay identification. 6 Finger grips for easy removal of the relay from a socket. 7 Eight or eleven cylindrical pins (RUM2C and RUM3C versions). 8 Eight or eleven quick-connect (Faston type) pins (RUM2F and RUM3F versions). 3 4 5 7 8 1 Socket description Outputs Sockets with mixed contact terminals (2) 1 Connection by screw connector. 2 Eight or eleven female contacts for the relay cylindrical pins. 3 Location for protection modules or timer module. 4 Locking component for metal hold-down clip. 5 Locating slot for mounting on DIN rail. 6 Two fixing holes for panel mounting. 2 6 4 3 Relay supply 5 Inputs Relay suppy 6 1 1 Sockets with separate contact terminals (3) 1 Connection by screw connector. 2 a Eight or eleven female contacts for the relay cylindrical pins. Outputs b Eleven female contacts for the relay flat pins. 2b 3 Location for protection modules or timer module. 4 Locking component for metal hold-down clip. 5 Locating slot for mounting on DIN rail with fixing clip. 4 6 Two fixing holes for panel mounting. 7 Location for bus jumpers (see dimensions for mounting on sockets on page 10). 3 Inputs Inputs Outputs 4 2a 3 57 5 Specifications: page 6 Relay supply 57 5 Relay supply References: page 8 (1) During operation, this lock-down door must always be in the closed position. (2) The inputs are mixed with the relay's coil terminals, with the outputs being located on the opposite side of the socket. (3) The inputs and outputs are separated from the relay coil terminals. Dimensions: page 10 Wiring diagrams: page 12 Functions: page 14 5 ZelioTM Plug-In Relays Specifications RUM universal relays General Specifications Conforming to standards Product certifications Ambient air temperature around the device Storage Operation Vibration resistance In operation conforming to IEC/EN 60068-2-6 Not operating Degree of protection Conforming to IEC/EN 60529 Shock resistance Opening conforming to IEC/EN 60068-2-27 Closing Protection category Mounting position C (F) C (F) Insulation Specifications Rated insulation voltage (Ui) IEC/EN 61810-1, UL 508, CSA C22-2 n 14 cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8; CSA; CE; GOST; RoHS compliant - 40 to + 85 (-40 to +185) - 40 to + 55 (-40 to +131) 3 gn (35 to 150 Hz) and 1 mm (10 to 35 Hz); 5 cycles 4 gn (35 to 150 Hz) and 1 mm (10 to 35 Hz); 5 cycles IP 40 (housing only) 10 gn (11 ms) 10 gn (11 ms) RT I Any V 250 (IEC), 300 (UL, CSA) Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 s) Dielectric strength (rms voltage) Vac Vac Vac 2500 2000 1500 Conforming to IEC/EN 60947 Between coil and contact Between poles Between contacts Contact Specifications Relay type Number and type of contacts RUMF2ppp 2 C/O Contact materials RUMF3ppp 3 C/O For ambient temperature y 55C Rated operational current Conforming to IEC in utilization categories AC-1 and DC-1 Conforming to UL A 10 NO A 10 at 250 Vac 10 at 28 Vdc NC A 5 at 250 Vac 5 at 28 vdc Resistive A 10 at 277 Vac (200k cycles) 10 at 30 Vdc (200k cycles) Motor HP Motor: 1/3 at 120 Vac (6k cycles) Motor: 1 at 277 Vac (6k cycles) Pilot Duty B300 (6k cycles) Minimum switching requirement mA Maximum switching voltage V 250 V (IEC) / 300 V (UL,CSA) VA 2500 VA (IEC), 2770 VA (UL) Maximum Vac Vdc Minimum Maximum operating rate In operating cycles/hour 10 at 17 Vdc; MCTF 10 million W 280 W (IEC) / 300 W (UL) mW 170 No-load 18000 Under load 1200 Utilization coefficient 20% Mechanical durability Cycles 5,000,000 Electrical durability Operating cycles Resistive load 100,000 (unless otherwise specified) Inductive load Electrical durability of contacts Resistive load Vac Reduction coefficient for inductive load Vac (depending on power factor cos ) Reduction coefficient (A) RUMC3App 3 C/O AgNi Conventional thermal current (Ith) Switching capacity RUMC2ppp 2 C/O See curve below 1 0.8 0.6 0.5 0.4 0.3 1 0.6 0.4 0.2 RUMFppppp, RUMC2ppp, RUMC3Appp Durability (inductive load) = durability (resistive load) x reduction coefficient. Introduction: page 5 6 References: page 8 Dimensions: page 10 Wiring diagrams: page 12 Functions: page 14 ZelioTM Plug-In Relays Specifications (continued) RUM universal relays Coil Specifications Average consumption VA 3 W 1.4 Drop-out voltage threshold u 0.15 Uc (at minimum operating temperature) u 0.1 Uc (at minimum operating temperature) Response time Operate time ms Release time ms 20 max V 12 24 48 60 110 120 125 220 230 JD BD ED ND FD - GD MD - 120 470 1800 2790 7300 - 7300 37,000 - Min. V 9.6 19.2 38.4 48 88 - 100 176 - Max. V 13.2 26.4 52.8 66 121 - 137.5 242 - - B7 E7 - - F7 - - P7 - 72 290 - - 1700 - - 6800 Min. V - 19.2 38.4 - - 96 - - 184 Max. V - 26.4 52.8 - - 132 - - 253 Control circuit voltage Uc Relay control voltage codes d.c. supply Average resistance at 20 C 10% Operating voltage limits Relay control voltage codes a.c. supply Average resistance at 20 C 15% Operating voltage limits Socket Specifications 20 max (at 100% coil voltage) Socket type RUZC2M RUZC3M RUZSC2M RUZSC3M RUZSF3M Relay types used RUMC2ppppp RUMC3ppppp RUMC2ppppp RUMC3ppppp RUMFppppp Contact terminal arrangement Mixed Wire connection method Connector Product certifications UL, CSA Conforming to standards IEC 61984, e Electrical Specifications Separate Conventional thermal current (Ith) A 10 Maximum operating voltage V 250 (IEC) Between adjacent output contacts Vrms 2500 Between input and output contacts Vrms 2500 Between contacts and DIN rail Vrms 2500 Ambient air temperature around the device Storage C (F) - 40 to + 85 (-40 to +185) Operation C (F) - 40 to + 55 (-40 to +131) Insulation Specifications General Specifications 12 Degree of protection Conforming to IEC/EN 60529 IP 20 Cabling Solid cable without cable end 1 conductor 0.5 to 2.5 mm2 - AWG 20 to AWG 14 2 conductors 0.5 to 1.5 mm2 - AWG 20 to AWG 16 Flexible cable with cable end 1 conductor 0.25 to 2.5 mm2 - AWG 22 to AWG 14 2 conductors 0.25 to 1 mm2 - AWG 22 to AWG 17 Maximum tightening torque / Screw size Nm 1 / M3.3 screw Mounting On 35 mm DIN rail / on panel Fixing on DIN rail By red plastic clip Terminal referencing IEC, NEMA Bus jumper (Ith: 5 A) No Compatibility with the metal maintaining clamp Yes Timer module Yes Protection module All RUW24ppp Clip-in legends Wire connection method Introduction: page 5 No Yes Yes Screw connector References: page 8 Dimensions: page 10 Wiring diagrams: page 12 Functions: page 14 7 ZelioTM Plug-In Relays References RUM universal relays References Pins Control circuit voltage Number and type of contacts - Thermal current (Ith) 2 C/O - 10 A 3 C/O - 10 A Unit reference Weight Unit reference kg/lb Universal relays with lockable test button only (sold in lots of 10) Cylindrical RUMC21BD Flat (Faston type) RUMC21F7 RUMC32BD Flat (Faston type) RUMF33P7 Introduction: page 5 8 RUMC21JD RUMC21BD RUMC21ED - RUMC21FD - - RUMC21B7 RUMC21E7 RUMC21F7 RUMC21P7 RUMF21JD RUMF21BD RUMF21ED RUMF21FD RUMF21B7 RUMF21E7 RUMF21F7 RUMF21P7 0.086/0.190 0.086/0.190 0.086/0.190 - 0.086/0.190 - - 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 RUMC31JD RUMC31BD RUMC31ED RUMC31ND RUMC31FD RUMC31GD RUMC31MD RUMC31B7 RUMC31E7 RUMC31F7 RUMC31P7 RUMF31JD RUMF31BD RUMF31ED RUMF31FD RUMF31B7 RUMF31E7 RUMF31F7 RUMF31P7 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 RUMC22JD RUMC22BD RUMC22ED - RUMC22FD - RUMC22B7 RUMC22E7 RUMC22F7 RUMC22P7 RUMF22JD RUMF22BD RUMF22ED RUMF22FD RUMF22B7 RUMF22E7 RUMF22F7 RUMF22P7 0.086/0.190 0.086/0.190 0.086/0.190 - 0.086/0.190 - 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 RUMC32JD RUMC32BD RUMC32ED RUMC32ND RUMC32FD RUMC32GD 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 RUMC23JD RUMC23BD RUMC23ED - RUMC23FD - RUMC23B7 RUMC23E7 RUMC23F7 RUMC23P7 RUMF23JD RUMF23BD RUMF23ED RUMF23FD RUMF23B7 RUMF23E7 RUMF23F7 RUMF23P7 0.086/0.190 0.086/0.190 0.086/0.190 - 0.086/0.190 - 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 RUMC33JD RUMC33BD RUMC33ED RUMC33ND RUMC33FD RUMC33GD Universal relays with lockable test button and LED (sold in lots of 10) Cylindrical RUMF32F7 12 Vdc 24 Vdc 48 Vdc 60 Vdc 110 Vdc 125 Vdc 220 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 12 Vdc 24 Vdc 48 Vdc 60 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac Universal relays with LED only (sold in lots of 10) Cylindrical pins Quick-connect pins Specifications: page 6 12 Vdc 24 Vdc 48 Vdc 60 Vdc 110 Vdc 125 Vdc 24 Vac 48 Vac 120 Vac 230 Vac 12 Vdc 24 Vdc 48 Vdc 110 Vdc 24 Vac 48 Vac 120 Vac 230 Vac Dimensions: page 10 Weight kg/lb Wiring diagrams: page 12 RUMC32B7 RUMC32E7 RUMC32F7 RUMC32P7 RUMF32JD RUMF32BD RUMF32ED RUMF32FD RUMF32B7 RUMF32E7 RUMF32F7 RUMF32P7 RUMC33B7 RUMC33E7 RUMC33F7 RUMC33P7 RUMF33JD RUMF33BD RUMF33ED RUMF33FD RUMF33B7 RUMF33E7 RUMF33F7 RUMF33P7 Functions: page 14 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 0.086/0.190 References (continued) ZelioTM Plug-In Relays RUM universal relays References (continued) Sockets Contact terminal arrangement Mixed Separate Connection Relay type Sold in lots of Unit reference Screw connector RUMC2ppp 10 RUZC2M 0.054/0.119 RUMC3ppp 10 RUZC3M 0.054/0.119 RUMC2ppp 10 RUZSC2M 0.095/0.209 RUMC3ppp 10 RUZSC3M 0.100/0.220 RUMF2ppp 10 RUZSF3M 0.095/0.209 Screw connector Weight kg/lb RUMF3ppp RUZSC3M + Relay RUMC3ppp Protection modules Description For use with Voltage Sold in lots of Unit reference Weight Diode All RUM sockets 6 to 250 Vdc 10 RUW240BD 0.004/0.009 RC circuit All RUM sockets 110 to 240 Vac 10 RUW241P7 0.004/0.009 Varistor All RUM sockets 24 Vac/Vdc 10 RUW242B7 0.004/0.009 240 Vac/Vdc 10 RUW242P7 0.004/0.009 kg/lb RUW241P7 Timer module Description For use with Voltage Reference All RUM sockets 24 to 240 Vac/Vdc RUW101MW Weight kg/lb Multifunction RUW101MW Accessories Description RUZC200 0.020/0.044 For use with Sold in lots of Unit reference Weight kg/lb Metal maintaining clamp All RUM sockets 10 RUZC200 0.001/0.002 Bus jumper 2-pole (Ith : 5 A) All RUM sockets with separate contacts 10 RUZS2 0.005/0.011 Clip-in ID tags All relays (sheet of 108 legends) 10 RXZL520 0.080/0.190 All RUM sockets with separate contacts 10 RUZL420 0.001/0.002 RUZS2 Introduction: page 5 Specifications: page 6 Dimensions: page 10 Wiring diagrams: page 12 Functions: page 14 9 ZelioTM Plug-In Relays Dimensions RUM universal relays Dimensions: mm (in.) Universal relays RUMFpp 6 (0.24) 56 (2.20) 35.4 (1.39) 35.4 (1.39) RUMCpp 35 (1.37) 6 (0.24) 53 (2.08) 35 (1.37) Sockets Common side view RUZC2M RUZC3M 22 (0.86) 24 22 6 (1) 4 3 A2 14 12 5 3 4 21 7 6 7 4 3 10 11 1 2 11 1 INPUT A2 10 A2 A2 A1 8 2 10 2xO3.1 (2xO0.12) 5 9 37 (1.45) 37 (1.45) 7 4 (0.15) 63 (2.48) 22 7 8 INPUT A1 2 INPUT A2 7 89 (3.50) 24 8 1 8 A2 32 9 2 7 (2) 34 2xO3.1 (2xO0.12) 4 5 27 (1.06) 3 6 74 (2.91) (3) 12 14 5 31 10 21 11 INPUT A1 2 11 6 30 (1.18) 30 (1.18) 38 (1.49) 38 (1.49) A1 1 2 93 (3.66) RUZSC2M RUZSC3M 63 (2.48) 45 (1.77) 19 (0.74) 22 5 24 6 11 1 21 8 19 (0.74) 12 4 31 11 14 3 24 7 14 3 32 22 12 7 4 (0.15) 29 75 (2.95) (1.14) (1) 2 8 1 (2) A2 7 (4) (3) A1 2 101 (3.98) 75 (2.95) 29 (1.14) 101 (3.98) 105 (4.13) 105 (4.13) (1) Relays (2) Protection or timer module (3) Maintaining clamp (4) 2 bus jumpers Introduction: page 5 10 Specifications: page 6 References: page 8 5 4 7 6 5 8 4 3 9 10 2 11 1 A2 10 (4) 30 (1.18) 36 (1.41) O4 (O0.15) 40 (1.57) (2) 3 92 (3.62) 6 40 (1.57) (1) 4 4 (0.15) 92 (3.62) (3) 5 11 1 34 9 8 O4 (O0.15) 21 6 Wiring diagrams: page 12 Functions: page 14 A1 2 32 (1.25) 36 (1.41) ZelioTM Plug-In Relays Dimensions (continued) RUM universal relays Dimensions: mm (in.) (continued) Sockets (continued) RUZSF3M 63 (2.48) 21 9 11 7 24 6 34 5 14 4 22 32 12 3 2 1 92 (3.62) (1) 31 8 (3) (2) A2 B 24 (0.94) 46 (1.81) 104 (4.09) 29 (1.14) 4 (0.15) (4) A1 A 36 (1.41) (1) Relays (2) Protection or module (3) Maintaining clamp (4) 2 bus jumpers Metal maintaining clamps and plastic legends Mounting 35 (1.37) RUZC200 120 (4.72) 59.6 (2.34) 0.8 (0.03) RUZL420 14.2 (0.55) 12 (0.47) 32 (1.25) Bus jumper Mounting on sockets with separate contacts (view from below) Example of bus jumper mounting on sockets 35.4 (1.39) (1) (1) (2) (2) 8.5 (0.33) 3.3 (0.12) RUZS2 32 (1.25) 2.3 (0.09) (1) 2 bus jumpers (polarity A2) (2) 2 bus jumpers (polarity A1) Introduction: page 5 Specifications: page 6 References: page 8 Wiring diagrams: page 12 Functions: page 14 11 ZelioTM Plug-In Relays Wiring diagrams RUM universal relays Wiring diagrams Universal relays RUMC2ppp 12 4 14 A1 RUMF2ppp 5 22 3 6 2 7 + 11 1 8 21 24 A2 RUMC3ppppp 1 3 12 4 22 6 14 7 24 9 11 A (+) 21 B( ) A1 A2 22 12 7 24 4 8 14 3 A1 32 9 34 2 + 10 1 11 24 A2 A1 22 21 34 32 31 RUMF3ppp 21 6 5 14 12 A2 A1 11 34 32 RUMF3ppp 31 24 22 21 14 12 A2 A1 11 24 22 RUMC3ppppp 21 14 11 12 RUMp2ppp 11 31 A2 1 2 3 12 4 32 5 22 6 14 7 34 8 24 9 11 A (+) 31 21 B( ) A2 A1 Symbols shown in blue correspond to NEMA marking. Introduction: page 5 12 Specifications: page 6 References: page 8 Dimensions: page 10 Functions: page 14 ZelioTM Plug-In Relays Wiring diagrams (continued) RUM universal relays Wiring diagrams (continued) Sockets RUZ C2M 6 RUZ C3M RUZ SC2M 5 4 3 9 8 7 5 3 24 22 12 14 34 32 24 22 14 12 6 7 7 A2 5 8 7 A2 4 1 8 21 7 3 8 2 9 10 1 11 2 A1 10 10 A2 A2 6 5 11 31 6 21 4 12 3 14 1 11 8 21 6 21 7 24 5 22 11 31 8 32 9 34 4 5 3 11 1 RUZ SC3M 5 22 6 24 4 4 2 7 1 11 8 7 A2 2 A1 8 3 6 1 7 9 10 2 2 A1 6 5 1 11 4 12 3 14 4 3 11 1 2 2 A1 10 A2 Symbols shown in blue correspond to NEMA marking. RUZ SF3M 9 21 6 24 8 31 5 34 7 11 4 14 3 22 2 32 1 12 B A2 A A1 Symbols shown in blue correspond to NEMA marking. Protection modules RUW 240BD RUW 241P7 RUW 242pp - A2 - A2 - A2 + A1 + A1 + A1 Introduction: page 5 Specifications: page 6 References: page 8 Dimensions: page 10 Functions: page 14 13 ZelioTM Plug-In Relays Functions RUM universal relays Multifunction timer module RUW 101MW Programming Timing range selection Function Timing range selection selection 0.1 to 1 s 0.1 to 10 s 0.1 to 1 min 1 to 10 min 0.1 to 1 h 0.1 to 1 day 1 to 10 h 1 to 10 days Function selection Series control Monostable with maintained control Wu Series control Flashing relay, starting On-delay phase Bi Series control Flashing relay, starting Off-delay phase Bp Series control Off-delay timer R U .1/.4 .1/.2 U t U .1/.4 .1/.2 R t U .1/.4 .1/.2 t t U .1/.4 .1/.2 Control by external contact (S) t t U U S S .1/.4 .1/.2 Monostable, starting on de-energization Wa On-delay Timer Es Control by external contact (S) U R S .1/.4 .1/.2 Control by external contact (S) t U S .1/.4 .1/.2 Control by external contact (S) t U S .1/.4 .1/.2 t Power off Contact open U : voltage S : external control Power on Contact closed R : relay RUM ppp t : adjustable time delay References: page 8 Dimensions: page 10 Introduction: page 5 14 t A2 Monostable with pulse control Ws Specifications: page 6 Control scheme B1 On-delay Timer E Function diagram A1 Control A2 Function A1 Selection Wiring diagrams: page 12 Schneider Electric USA, Inc. 8001 Knightdale Blvd. Knightdale, NC 27545 www.schneider-electric.com USA Customer Care Center Tel: 888-778-2733 Schneider Electric Canada (c) 2014 Schneider Electric. All rights reserved. Schneider Electric, Zelio, and "Make the most of your energy" are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. Canada Customer Care Center Tel: 800-565-6699 Design: Schneider Electric Photos: Schneider Electric 5985 McLaughlin Rd. Missassauga, Ontario, Canada L5R 1B8 DIA3ED2090304EN-RUM-US 9/2014