Zelio
Plug-In Relays
RUM universal range
Catalog
2014
3
Contents Zelio Plug-In Relays
RUM universal relays
bIntroduction ..................................................... 5
bSpecications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
bReferences ..................................................... 8
bDimensions .................................................... 10
bWiring diagrams ................................................. 12
bFunctions ...................................................... 14
4
5
Introduction of product range
The RUM universal relay product range includes:
1 10 A relays with 2 and 3 C/O contacts, and cylindrical or quick-connect (Faston
type) pins. All of these relays have the same dimensions.
2 Sockets with mixed or separate contact terminals.
3 Protection modules (diode, RC circuit or varistor) or 1 timer module, common to
all RUM sockets.
4 Metal maintaining clamp for all RUM sockets.
5 2-pole bus jumper that can be used on sockets with separate contact terminals
in order to simplify cabling when creating an equipotential link between the
coil terminals.
6 Clip-in legends for the sockets.
Relay description
1 Spring return pushbutton for testing the contacts (green: Vdc coil; red: Vac coil).
2 Mechanical “relay status” indicator.
3 Removable lock-down door enables continuous engagement of the contacts for
test or maintenance purposes.(1).
4 Optional bipolar LED indicating the relay status.
5 RemovableIDtagforrelayidentication.
6 Finger grips for easy removal of the relay from a socket.
7 Eight or eleven cylindrical pins (RUM2C and RUM3C versions).
8 Eight or eleven quick-connect (Faston type) pins (RUM2F and RUM3F versions).
Socket description
Sockets with mixed contact terminals (2)
1 Connection by screw connector.
2 Eight or eleven female contacts for the relay cylindrical pins.
3 Location for protection modules or timer module.
4 Locking component for metal hold-down clip.
5 Locating slot for mounting on DIN rail.
6 Twoxingholesforpanelmounting.
Sockets with separate contact terminals (3)
1 Connection by screw connector.
2 a Eight or eleven female contacts for the relay cylindrical pins.
bElevenfemalecontactsfortherelayatpins.
3 Location for protection modules or timer module.
4 Locking component for metal hold-down clip.
5 LocatingslotformountingonDINrailwithxingclip.
6 Twoxingholesforpanelmounting.
7 Location for bus jumpers (see dimensions for mounting on sockets on page 10).
(1) During operation, this lock-down door must always be in the closed position.
(2) The inputs are mixed with the relay's coil terminals, with the outputs being located on the
opposite side of the socket.
(3) The inputs and outputs are separated from the relay coil terminals.
Zelio Plug-In Relays
RUM universal relays
Introduction
1
2
3
4
5
6
6
5
2
1
3
4
7 8
1
2
3
4
5
6
Outputs
Relay supply
Inputs
Relay suppy
1
6
2a
3
4
5 7
Inputs
Outputs
Relay supply
5
1
2b
3
4
5 7
Inputs
Outputs
Relay supply
5
Specications:
page 6
References:
page 8
Dimensions:
page 10
Wiring diagrams:
page 12
Functions:
page 14
6
General Specications
Conforming to standards IEC/EN 61810-1, UL 508, CSA C22-2 n° 14
Product certications cULus File E164862 CCN NLDX, NLDX7; cURus File E164862 CCN NLDX2, NLDX8;
CSA; CE; GOST; RoHS compliant
Ambient air temperature
around the device
Storage °C (F) - 40 to + 85 (-40 to +185)
Operation °C (F) - 40 to + 55 (-40 to +131)
Vibration resistance
conforming to IEC/EN 60068-2-6
In operation 3 gn (35 to 150 Hz) and ± 1 mm (10 to 35 Hz); 5 cycles
Not operating 4 gn (35 to 150 Hz) and ± 1 mm (10 to 35 Hz); 5 cycles
Degree of protection Conforming to IEC/EN 60529 IP 40 (housing only)
Shock resistance
conforming to IEC/EN 60068-2-27
Opening 10 gn (11 ms)
Closing 10 gn (11 ms)
Protection category RT I
Mounting position Any
Insulation Specications
Rated insulation voltage (Ui) Conforming to IEC/EN 60947 V250 (IEC), 300 (UL, CSA)
Rated impulse withstand voltage (Uimp) kV 4 (1.2/50 µs)
Dielectric strength
(rms voltage)
Between coil and contact Vac 2500
Between poles Vac 2000
Between contacts Vac 1500
Contact Specications
Relay type RUMF2ppp RUMF3ppp RUMC2ppp RUMC3App
Number and type of contacts 2 C/O 3 C/O 2 C/O 3 C/O
Contact materials AgNi
Conventional thermal
current (Ith)
For ambient
temperature y 55°C
A10
Rated operational current Conforming to IEC
in utilization
categories
AC-1 and DC-1
NO A10 at 250 Vac
10 at 28 Vdc
NC A5 at 250 Vac
5 at 28 vdc
Conforming to UL Resistive A10 at 277 Vac (200k cycles)
10 at 30 Vdc (200k cycles)
Motor HP Motor: 1/3 at 120 Vac (6k cycles)
Motor: 1 at 277 Vac (6k cycles)
Pilot Duty B300 (6k cycles)
Minimum switching requirement mA 10at17Vdc;MCTF≥10million
Maximum switching voltage V250 V (IEC) / 300 V (UL,CSA)
Switching capacity Maximum Vac VA 2500 VA (IEC), 2770 VA (UL)
Vdc W280 W (IEC) / 300 W (UL)
Minimum mW 170
Maximum operating rate
In operating cycles/hour
No-load 18000
Under load 1200
Utilization coefcient 20%
Mechanical durability Cycles 5,000,000
Electrical durability
Operating cycles
Resistive load 100,000(unlessotherwisespecied)
Inductive load See curve below
Electrical durability of contacts Resistive load Vac
ReductioncoefcientforinductiveloadVac
(depending on power factor cos ϕ)
RUMFppppp, RUMC2ppp, RUMC3Appp
Durability(inductiveload)=durability(resistiveload)xreductioncoefcient.
Zelio Plug-In Relays
RUM universal relays
Specications
0.3
0.5
0.61 0.4 0.2
0.4
0.6
0.8
1
Reductioncoefcient(A)
Introduction:
page 5
References:
page 8
Dimensions:
page 10
Wiring diagrams:
page 12
Functions:
page 14
7
Coil Specications
Average consumption VA 3
W1.4
Drop-out voltage threshold u 0.15 Uc (at minimum operating temperature)
u 0.1 Uc (at minimum operating temperature)
Response time Operate time ms 20 max (at 100% coil voltage)
Release time ms 20 max
Control circuit voltage Uc V 12 24 48 60 110 120 125 220 230
Relay control voltage codes JD BD ED ND FD GD MD
d.c. supply Average resistance at 20 °C ± 10% 120 470 1800 2790 7300 7300 37,000
Operating
voltage limits
Min. V9.6 19.2 38.4 48 88 100 176
Max. V13.2 26.4 52.8 66 121 137.5 242
Relay control voltage codes B7 E7 F7 P7
a.c. supply Average resistance at 20 °C ± 15% 72 290 1700 6800
Operating
voltage limits
Min. V 19.2 38.4 96 184
Max. V 26.4 52.8 132 253
Socket Specications
Socket type RUZC2M RUZC3M RUZSC2M RUZSC3M RUZSF3M
Relay types used RUMC2ppppp RUMC3ppppp RUMC2ppppp RUMC3ppppp RUMFppppp
Contact terminal arrangement Mixed Separate
Wire connection method Connector
Product certications UL, CSA
Conforming to standards IEC 61984, e
Electrical Specications
Conventional thermal current (Ith) A10 12
Maximum operating voltage V250 (IEC)
Insulation Specications
Between adjacent output contacts Vrms 2500
Between input and output contacts Vrms 2500
Between contacts and DIN rail Vrms 2500
General Specications
Ambient air temperature
around the device
Storage °C (F) - 40 to + 85 (-40 to +185)
Operation °C (F) - 40 to + 55 (-40 to +131)
Degree of protection Conforming to IEC/EN 60529 IP 20
Cabling Solid cable
without
cable end
1 conductor 0.5 to 2.5 mm2 - AWG 20 to AWG 14
2 conductors 0.5 to 1.5 mm2 - AWG 20 to AWG 16
Flexible cable
with cable end
1 conductor 0.25 to 2.5 mm2 - AWG 22 to AWG 14
2 conductors 0.25 to 1 mm2 - AWG 22 to AWG 17
Maximum tightening torque / Screw size Nm 1 / M3.3 screw
Mounting On 35 mm DIN rail / on panel
Fixing on DIN rail By red plastic clip
Terminal referencing IEC, NEMA
Bus jumper (Ith: 5 A) No Yes
Compatibility with the metal maintaining clamp Yes
Timer module Yes
Protection module All RUW24ppp
Clip-in legends No Yes
Wire connection method Screw connector
Zelio Plug-In Relays
RUM universal relays
Specications (continued)
Introduction:
page 5
References:
page 8
Dimensions:
page 10
Wiring diagrams:
page 12
Functions:
page 14
8
References
Pins Control
circuit voltage
Number and type of contacts - Thermal current (Ith)
2 C/O - 10 A 3 C/O - 10 A
Unit reference Weight Unit reference Weight
kg/lb kg/lb
Universal relays with lockable test button only (sold in lots of 10)
Cylindrical 12 Vdc RUMC21JD 0.086/0.190 RUMC31JD 0.086/0.190
24 Vdc RUMC21BD 0.086/0.190 RUMC31BD 0.086/0.190
48 Vdc RUMC21ED 0.086/0.190 RUMC31ED 0.086/0.190
60 Vdc RUMC31ND 0.086/0.190
110 Vdc RUMC21FD 0.086/0.190 RUMC31FD 0.086/0.190
125 Vdc RUMC31GD 0.086/0.190
220 Vdc RUMC31MD 0.086/0.190
24 Vac RUMC21B7 0.086/0.190 RUMC31B7 0.086/0.190
48 Vac RUMC21E7 0.086/0.190 RUMC31E7 0.086/0.190
120 Vac RUMC21F7 0.086/0.190 RUMC31F7 0.086/0.190
230 Vac RUMC21P7 0.086/0.190 RUMC31P7 0.086/0.190
Flat (Faston type) 12 Vdc RUMF21JD 0.086/0.190 RUMF31JD 0.086/0.190
24 Vdc RUMF21BD 0.086/0.190 RUMF31BD 0.086/0.190
48 Vdc RUMF21ED 0.086/0.190 RUMF31ED 0.086/0.190
110 Vdc RUMF21FD 0.086/0.190 RUMF31FD 0.086/0.190
24 Vac RUMF21B7 0.086/0.190 RUMF31B7 0.086/0.190
48 Vac RUMF21E7 0.086/0.190 RUMF31E7 0.086/0.190
120 Vac RUMF21F7 0.086/0.190 RUMF31F7 0.086/0.190
230 Vac RUMF21P7 0.086/0.190 RUMF31P7 0.086/0.190
Universal relays with lockable test button and LED (sold in lots of 10)
Cylindrical 12 Vdc RUMC22JD 0.086/0.190 RUMC32JD 0.086/0.190
24 Vdc RUMC22BD 0.086/0.190 RUMC32BD 0.086/0.190
48 Vdc RUMC22ED 0.086/0.190 RUMC32ED 0.086/0.190
60 Vdc RUMC32ND 0.086/0.190
110 Vdc RUMC22FD 0.086/0.190 RUMC32FD 0.086/0.190
125 Vdc RUMC32GD 0.086/0.190
24 Vac RUMC22B7 0.086/0.190 RUMC32B7 0.086/0.190
48 Vac RUMC22E7 0.086/0.190 RUMC32E7 0.086/0.190
120 Vac RUMC22F7 0.086/0.190 RUMC32F7 0.086/0.190
230 Vac RUMC22P7 0.086/0.190 RUMC32P7 0.086/0.190
Flat (Faston type) 12 Vdc RUMF22JD 0.086/0.190 RUMF32JD 0.086/0.190
24 Vdc RUMF22BD 0.086/0.190 RUMF32BD 0.086/0.190
48 Vdc RUMF22ED 0.086/0.190 RUMF32ED 0.086/0.190
110 Vdc RUMF22FD 0.086/0.190 RUMF32FD 0.086/0.190
24 Vac RUMF22B7 0.086/0.190 RUMF32B7 0.086/0.190
48 Vac RUMF22E7 0.086/0.190 RUMF32E7 0.086/0.190
120 Vac RUMF22F7 0.086/0.190 RUMF32F7 0.086/0.190
230 Vac RUMF22P7 0.086/0.190 RUMF32P7 0.086/0.190
Universal relays with LED only (sold in lots of 10)
Cylindrical pins 12 Vdc RUMC23JD 0.086/0.190 RUMC33JD 0.086/0.190
24 Vdc RUMC23BD 0.086/0.190 RUMC33BD 0.086/0.190
48 Vdc RUMC23ED 0.086/0.190 RUMC33ED 0.086/0.190
60 Vdc RUMC33ND 0.086/0.190
110 Vdc RUMC23FD 0.086/0.190 RUMC33FD 0.086/0.190
125 Vdc RUMC33GD 0.086/0.190
24 Vac RUMC23B7 0.086/0.190 RUMC33B7 0.086/0.190
48 Vac RUMC23E7 0.086/0.190 RUMC33E7 0.086/0.190
120 Vac RUMC23F7 0.086/0.190 RUMC33F7 0.086/0.190
230 Vac RUMC23P7 0.086/0.190 RUMC33P7 0.086/0.190
Quick-connect pins 12 Vdc RUMF23JD 0.086/0.190 RUMF33JD 0.086/0.190
24 Vdc RUMF23BD 0.086/0.190 RUMF33BD 0.086/0.190
48 Vdc RUMF23ED 0.086/0.190 RUMF33ED 0.086/0.190
110 Vdc RUMF23FD 0.086/0.190 RUMF33FD 0.086/0.190
24 Vac RUMF23B7 0.086/0.190 RUMF33B7 0.086/0.190
48 Vac RUMF23E7 0.086/0.190 RUMF33E7 0.086/0.190
120 Vac RUMF23F7 0.086/0.190 RUMF33F7 0.086/0.190
230 Vac RUMF23P7 0.086/0.190 RUMF33P7 0.086/0.190
Zelio Plug-In Relays
RUM universal relays
References
RUMC21BD
RUMC21F7
RUMC32BD
RUMF32F7
RUMF33P7
Introduction:
page 5
Specications:
page 6
Dimensions:
page 10
Wiring diagrams:
page 12
Functions:
page 14
9
References (continued)
Sockets
Contact terminal
arrangement
Connection Relay type Sold in
lots of
Unit
reference
Weight
kg/lb
Mixed Screw connector RUMC2ppp 10 RUZC2M 0.054/0.119
RUMC3ppp 10 RUZC3M 0.054/0.119
Separate Screw connector RUMC2ppp 10 RUZSC2M 0.095/0.209
RUMC3ppp 10 RUZSC3M 0.100/0.220
RUMF2ppp 10 RUZSF3M 0.095/0.209
RUMF3ppp
Protection modules
Description For
use with
Voltage Sold in
lots of
Unit
reference
Weight
kg/lb
Diode All RUM sockets 6 to 250 Vdc 10 RUW240BD 0.004/0.009
RC circuit All RUM sockets 110 to 240 Vac 10 RUW241P7 0.004/0.009
Varistor All RUM sockets 24 Vac/Vdc 10 RUW242B7 0.004/0.009
240 Vac/Vdc 10 RUW242P7 0.004/0.009
Timer module
Description For
use with
Voltage Reference Weight
kg/lb
Multifunction All RUM sockets 24 to 240 Vac/Vdc RUW101MW 0.020/0.044
Accessories
Description For
use with
Sold in
lots of
Unit
reference
Weight
kg/lb
Metal maintaining clamp All RUM sockets 10 RUZC200 0.001/0.002
Bus jumper 2-pole (Ith : 5 A) All RUM sockets with separate contacts 10 RUZS2 0.005/0.011
Clip-in ID tags All relays
(sheet of 108 legends)
10 RXZL520 0.080/0.190
All RUM sockets with separate contacts 10 RUZL420 0.001/0.002
Zelio Plug-In Relays
RUM universal relays
References (continued)
RUW101MW
RUW241P7
RUZSC3M +
Relay RUMC3ppp
RUZC200
RUZS2
Introduction:
page 5
Specications:
page 6
Dimensions:
page 10
Wiring diagrams:
page 12
Functions:
page 14
10
Dimensions: mm (in.)
Universal relays
RUMCpp RUMFpp
Sockets
Common side view RUZC2M RUZC3M
2xØ3.1
(2xØ
0.12)
38 (1.49)
37
(1.45)
30 (1.18)
24
6
2
7
A2
7
A1
2
11
1
21
8
A2
7
INPUT A2 INPUT A1
22
5
12
4
1
4
2
3
8
5
7
6
14
3
A2
10
A2
10
31
11
21
6
11
1
A1
2
34
9
32
8
24
7
22
5
14
3
12
4
2
10
1
6
2
5
3
4
11
10
7
9
8
INPUT A2
INPUT A1
2xØ3.1
(2xØ
0.12)
38 (1.49)
37
(1.45)
30 (1.18)
RUZSC2M RUZSC3M
(1) Relays
(2) Protection or timer module
(3) Maintaining clamp
(4) 2 bus jumpers
56
(2.20)
35
(1.37)
35.4
(1.39)
6
(0.24)
35.4
(1.39)
35
(1.37)
53
(2.08)
6
(0.24)
Ø4
(Ø0.15)
36 (1.41)
75 (2.95)
101 (3.98)
105 (4.13)
29
(1.14)
92 (3.62)4
(0.15)
40
(1.57)
30 (1.18)
19
(0.74)
45
(1.77)
22
5
11
1
12
4
24
6
1
4
2
3
8
5
7
6
A2
7
A1
2
21
8
14
3
(4)
(1)
(3)
(2)
31
11
21
6
11
1
32
8
22
5
12
4
34
9
2
1
5
3
4
11
76
10
9
8
A2
10
A1
2
24
7
14
3
75 (2.95)
101 (3.98)
105 (4.13)
29
(1.14)
92 (3.62)
4
(0.15)
19
(0.74)
63
(2.48)
Ø4
(Ø0.15)
36 (1.41)
40
(1.57)
32 (1.25)
(1)
(3)
(2)
(4)
Zelio Plug-In Relays
RUM universal relays
Dimensions
Introduction:
page 5
Specications:
page 6
References:
page 8
Wiring diagrams:
page 12
Functions:
page 14
11
Dimensions: mm (in.) (continued)
Sockets (continued)
RUZSF3M
36
(1.41)
104 (4.09)
29
(1.14)
46 (1.81)24
(0.94)
92 (3.62)4
(0.15)
63
(2.48)
21
9
31
8
11
7
22
3
32
2
12
1
24
6
A2
B
A1
A
34
5
14
4
(1)
(3)
(2)
(4)
(1) Relays
(2) Protection or module
(3) Maintaining clamp
(4) 2 bus jumpers
Metal maintaining clamps and plastic legends
RUZC200 Mounting
0.8
(0.03)
59.6
(2.34)
35
(1.37)
120
(4.72)
RUZL420
12
(0.47)
14.2
(0.55)
32
(1.25)
Bus jumper
RUZS2 Mounting on sockets with separate contacts (view from below)
Example of bus jumper mounting on sockets
(2)(2)
(1)(1)
(1) 2 bus jumpers (polarity A2)
(2) 2 bus jumpers (polarity A1)
3.3 (0.12)
8.5
(0.33)
35.4
(1.39)
32
(1.25) 2.3
(0.09)
Dimensions (continued) Zelio Plug-In Relays
RUM universal relays
Introduction:
page 5
Specications:
page 6
References:
page 8
Wiring diagrams:
page 12
Functions:
page 14
12
Wiring diagrams Zelio Plug-In Relays
RUM universal relays
Wiring diagrams
Universal relays
RUMp2ppp RUMC3ppppp RUMF3ppp
RUMC2ppp RUMF2ppp RUMC3ppppp RUMF3ppp
Symbols shown in blue correspond to NEMA marking.
12
11 14
22
21 24
A2A1
12
11 14
22
21 24
32
31 34
A2A1
12
11 14
22
21 24
32
31 34
A2A1
3
7
18
6
2
45
A1 A2
2111
14 24
22
12
+
1
12
4
14
7
11
3
22
6
24
9
21
A
A1
B
A2
(+) ( )
4
39
2
111
10
8
5
6
7
A1 A2
14 34
3111
12 32
22 24
21
+
(+)
1
12
4
14
7
11
2
32
5
34
8
31
3
22
6
24
9
21
A
A1
B
A2
( )
Introduction:
page 5
Specications:
page 6
References:
page 8
Dimensions:
page 10
Functions:
page 14
13
Wiring diagrams (continued)
Sockets
RUZ C2M RUZ C3M RUZ SC2M RUZ SC3M
24
6
A2
7
A1
2
11
1
21
8
A2
7
22
5
12
4
1
4
2
3
8
5
7
6
14
3
32
8
34
9
A2
10
A1
2
11
1
31
11
21
6
A2
10
24
7
22
5
14
3
12
4
1
6
2
5
3
4
11
10
7
9
8
22
5
11
112
4
6
24 8
21
3
14
A2
7
A1
2
1
4
2
3
8
5
7
6
31
11
21
6
11
1
32
8
22
5
12
4
34
9
24
7
14
3
1
6
2
5
3
4
11
10
7
9
8
A2
10
A1
2
Symbols shown in blue correspond to NEMA marking.
RUZ SF3M
21
9
31
8
11
7
22
3
32
2
12
1
24
6
34
5
14
4
A2
B
A1
A
Symbols shown in blue correspond to NEMA marking.
Protection modules
RUW 240BD RUW 241P7 RUW 242pp
A2
+ A1
A2
+ A1
A2
+ A1
Zelio Plug-In Relays
RUM universal relays
Wiring diagrams (continued)
Introduction:
page 5
Specications:
page 6
References:
page 8
Dimensions:
page 10
Functions:
page 14
14
Multifunction timer module RUW 101MW
Programming Timing range selection
Function selection
Selection Function Control Function diagram Control scheme
On-delay Timer
E
Series control
Monostable with
maintained control
Wu
Series control
Flashing relay,
starting On-delay phase
Bi
Series control
Flashing relay,
starting Off-delay phase
Bp
Series control
Off-delay timer
R
Control by external contact
(S)
Monostable
with pulse control
Ws
Control by external contact
(S)
Monostable, starting
on de-energization
Wa
Control by external contact
(S)
On-delay Timer
Es
Control by external contact
(S)
Power off Contact open U : voltage S : external control
Power on Contact closed R : relay RUM ppp t : adjustable time delay
Function
selection
Timing range
selection
0.1 to 1 s 0.1 to 10 s 0.1 to 1 min 1 to 10 min 0.1 to 1 h 1 to 10 h 0.1 to 1 day 1 to 10 days
t
U
.1/.4
.1/.2
A1
A2
U
R
U
.1/.4
.1/.2
t
U
.1/.4
.1/.2
t t
U
.1/.4
.1/.2
t t
S
U
.1/.4
.1/.2
t
B1
A1
A2
U
R
S
S
U
.1/.4
.1/.2
t
S
U
.1/.4
.1/.2
t
S
U
.1/.4
.1/.2
t
Zelio Plug-In Relays
RUM universal relays
Functions
Introduction:
page 5
Specications:
page 6
References:
page 8
Dimensions:
page 10
Wiring diagrams:
page 12
© 2014 Schneider Electric. All rights reserved.
Schneider Electric, Zelio, and “Make the most of
yourenergy”aretrademarksownedbySchneiderElectricIndustriesSASoritsafliated
companies. All other trademarks are property of their respective owners.
Design: Schneider Electric
Photos: Schneider Electric
DIA3ED2090304EN-RUM-US
9/2014
www.schneider-electric.com
Schneider Electric USA, Inc.
8001 Knightdale Blvd.
Knightdale, NC 27545
USA Customer Care Center
Tel: 888-778-2733
Schneider Electric Canada
5985 McLaughlin Rd.
Missassauga, Ontario, Canada L5R 1B8
Canada Customer Care Center
Tel: 800 -565 - 669 9