First Edition Jan 20, 2000 OPTREX LCD Module Technical Specification Final Revision Aug 2,2001 Type No. DMF-50840NB-FW-AKE-AS Approved by (Production Div.) Checked by (Quality Assurance Div.) Checked by (Design Engineering Div.) Prepared by (Production Div.) Table of Contents 1. General Specifications .................................................................................................................................. 2 2. Electrical Specifications ............................................................................................................................... 3 3. Optical Specifications ................................................................................................................................... 8 4. I/O Terminal .................................................................................................................................................... 10 5. Test ................................................................................................................................................................... 12 6. Appearance Standards ............................................................................................................................... 13 7. Code System of Production Lot ............................................................................................................... 16 8. Type Number.................................................................................................................................................. 16 9. Applying Precautions .................................................................................................................................. 16 10. Precautions Relating Product Handling................................................................................................ 17 11. Warranty ........................................................................................................................................................ 18 Revision History Rev. 2 Date Aug 2,2001 Page 2,12 7 Comment Change of Operating Temperature.( 0C ~50C0C ~60C) 2.7 Lighting Specifications Change of Backlight's Average Life.(25000hrs50000hrs) 8 3.1 LCD Driving Voltage The driving voltage is changed along with the temperature range change.(Ta=60C Min.) DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 1/18 1. General Specifications Operating Temp. : min. 0C ~max. 60C Storage Temp. : min. -20C ~max. 60C Dot Pixels : 320 (W) Dot Size : 0.33 (W) x 0.33 (H) mm Dot Pitch : 0.36 (W) x 0.36 (H) mm Viewing Area : 120.0 (W) Outline Dimensions : 167.1 (W) x 109.0* (H) *Without Connector **Without CFL Cable Weight : 230g max. LCD Type : NTD-15885 ( STN / Blue-mode / Transmissive ) Viewing Angle : 6:00 Data Transfer : 4-bit parallel data transfer Backlight : Cold Cathode Fluorescent Lamp (CFL) Additional Spec. : Electroplated Coating of Black-Zinc on Steel Holder Type Drawings : Dimensional Outline x DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 240 (H) dots x 90.0 (H) mm x 11.0max.* (D) mm x 1 UE-36988 OPTREX CORPORATION Page 2/18 2. Electrical Specifications 2.1. Absolute Maximum Ratings VSS=0V Parameter Symbol Conditions Min. Max. Units Supply Voltage VCC -V SS - -0.3 7.0 V VCC -V EE - 0 35.0 V VI - -0.3 VCC +0.3 V (Logic) Supply Voltage (LCD Drive) Input Voltage 2.2. DC Characteristics Ta=25C, VSS=0V Parameter Symbol Conditions Min. Typ. Max. Units Supply Voltage VCC -V SS - 4.5 - 5.5 V VCC -V EE - 26.4 - 30.0 V (Logic) Supply Voltage (LCD Drive) High Level VCC -V ADJ Shown in 3.1 V VIH VCC =5.0V10% 0.8xVCC - VCC V VIL VCC =5.0V10% 0 - 0.2xVCC V ICC VCC -V SS=5.0V - 5.5 15.0 mA IEE VCC -V ADJ=23.3V - 5.0 10.0 mA Input Voltage Low Level Input Voltage Supply Current DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 3/18 2.3. AC Characteristics VCC =5.0V10% Parameter Symbol Min. Max. Units CP Frequency fCP - 6.0 MHz Clock Pulse Width tWC tWL 50 - ns 63 - ns tSETUP tHOLD tCL tLC tr, tf tFDS tFDH 30 - ns 30 - ns 80 - ns 0 - ns - Note 1 ns 100 - ns 100 - ns Latch Pulse Width Data Setup Time Data Hold Time Clock Pulse Setup Time Clock Pulse Hold Time Rise/Fall Time FLM Setup Time FLM Hold Time Note 1:The rise and fall times (tr, tf ) must satisfy the following relationships. 1 tr, tf tr, tf 50 ns 2fCP - tWC LP tWL tr tCL tf tLC tWC CP tWC tr tf tSETUP tHOLD D0~D3 tFDS tFDH FLM This module contains these capacitors. Please be careful about timing characteristics. FLM 1000pF LP 470pF M 1000pF VSS DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 4/18 2.4. Timing Chart T=0.0556ms typ. LP CP D0 SEG SEG D3 313~ 316 317~ 320 SEG SEG 1~ 4 5~ 8 #1 DATA SEG SEG 313~ 316 317~ 320 SEG SEG 1~ 4 5~ 8 FLM LP (Reduction) 240xT FLM (Reduction) 2.5. Comparison of Display and Data SEG1 #1 D3 SEG320 D2 D1 D0 D1 D0 TOP VIEW D0~D3 #240 DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 5/18 2.6. Power Supply ON/OFF Sequence 2.6.1. ON Sequence SIGNAL LEVEL VCC VCC VSS 0 t VCC SIGNAL VSS 0 t VCC VADJ VSS VEE VADJ VEE 0 t VCC DISPOFF VSS 2.6.2. OFF Sequence LEVEL SIGNAL VCC VSS VCC 0 t VCC VSS 0 t SIGNAL VCC VADJ VSS VEE VADJ VEE VCC 0 t VSS DISPOFF Please maintain the above sequence when turning on and off the power supply of the module. If DISPOFF is supplied to the module while internal alternate signal for LCD driving (M) is unstable, DC component will be supplied to the LCD panel. This may cause damage the LCD module. DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 6/18 2.7. Lighting Specifications Ta=25C Parameter Symbol Conditions Min. Typ. Max. Units Notes Lamp Voltage VL - - 340 - Vrms 1 Lamp Current IL - 3.0 4.0 5.0 mArms 2 VS - 850 - - Vrms 3 L IL=4.0mA - 60 - cd/m2 4 TAL IL=4.0mA 50000 - - hrs 5 B IL=4.0mA 70 - - % Starting Voltage Surface Luminance Average Life Brightne Ratio Note 1 :The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for 3 minutes . Note 2 :The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after lighting for 3 minutes. Note 3 :The voltage at starting the electric discharge when the voltage is increased gradually from 0V. Note 4 :Surface Luminance is specified by the average of 9 luminance values measured at each point shown above after 20 minutes power on with the all ON pattern adjusted to maximum contrast and the dimming control of 100%. ( maximum brightness ) Note 5 : CFL Life is defined as time period that the actual luminance becomes 50% or lower of its initial value. The Average life time of CFL is defined as the time when half or more of the testing CFLs have become less bright than 50% of the initial brightness at continuous operation. Y=60 I N VS VL V Y=160 Y=260 C P1 P2 P3 F P4 P5 P6 P7 P8 P9 L X=60 X=120 X=180 IL CFL Testing Circuit Measurement Points Recommended Inverter : S-12561 ( Produced by ELEVAM ) CXA-L10L (DC 12.0V, Produced by TDK) DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 7/18 3. Optical Specifications 3.1. LCD Driving Voltage Parameter Symbol Recommended LCD Driving Voltage VCC -V ADJ Note 1 Conditions Min. Typ. Max. Units Ta= 0C - - 26.4 V Ta=25C 21.7 23.3 24.9 V Ta=60C 20.0 - - V Note 1 : Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and response time are not guaranteed over the entire range. 3.2. Optical Characteristics Ta=25C, 1/240 Duty, 1/14 Bias, VOD =22.7V (Note 4), = 0C, =- Parameter Contrast Ratio Symbol Conditions Min. Typ. Max. CR = 0C , =- - 5 - Note 1 Viewing Angle Response Time Units Shown in 3.3 Rise Note 2 TON - - 250 380 ms Decay Note 3 TOFF - - 280 420 ms Note 1 :Contrast ratio is definded as follows. (CR = LON / LOFF) LON : Luminance of the ON segments LOFF : Luminance of the OFF segments Note 2 :The time that the luminance level reaches 90% of the saturation level from 0% when ON signal is applied. Note 3 :The time that the luminance level reaches 10% of the saturation level from 100% when OFF signal is applied. Note 4 :Definition of Driving Voltage VOD VOD =VCC -V ADJ-V BE Assuming that the typical driving waveforms shown below are applied to the LCD Panel at 1/A Duty - 1/B Bias (A: Duty Number, B: Bias Number). Driving voltage VOD is definded as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum. Vo-p ( B-2 ) xVo-p/B 1/( fFx A ) 1 /fF ( ON SIGNAL ) ( OFF SIGNAL ) DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 8/18 3.3. Definition of Viewing Angle and Optimum Viewing Area *Point * shows the point where contrast ratio is measured. : = 0, = - *Driving condition : 1/240 Duty, 1/14 Bias, VOD =22.7V, fF =75Hz 90 45 135 180 10 20 30 40 50 90 ( = 0) 180 225 0 315 270 270 *Area shows typ. CR2 3.4. System Block Diagram Temperature Chamber Rotation Table ( , ) Photometer #1980A WB LCD Optical Fiber Computer Control Unit & Waveform Generator Halogen bulb DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 9/18 4. I/O Terminal 4.1. Pin Assignment CN1 No. Symbol Level Function 1. D0 H/L Display Data 2. D1 H/L Display Data 3. D2 H/L Display Data 4. D3 H/L Display Data 5. DISPOFF H/L H : Display on L : Display off (Pull up Resister) 6. FLM H/L First Line Marker 7. NC - 8. LP HL Data Latch Signal 9. CP HL Clock Signal for Shifting Data 10. VCC - Power Supply for Logic 11. VSS - Power Supply (0V, GND) 12. VEE - Power Supply for LCD Drive 13. VADJ - Voltage Level for LCD Contrast Adjustment 14. FG - Frame Ground No. Symbol Level 1 CFL HOT - Power Supply for CFL (HOT) 2 NC - Non-connection 3 NC - Non-connection 4 CFL GND - Power Supply for CFL (GND) Non-connection CN2 Function 4.2. Example of Power Supply It is recommended to apply a potentiometer for the contrast adjust due to the tolerance of the driving voltage and its temperature dependence. VCC VCC (+Voltage) R1 VADJ VR MODULE R2 VEE VEE (-Voltage) VSS VSS (0V) R1+R2+VR=10~ 20K DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 10/18 4.3. Block Diagram Row Driver LC79430D x 3 or equivalent FLM 240 LCDP 320 x 240 dots 2 LP DISPOFF 320 2 Column Driver LC79401D x 4 or equivalent CP 4 D0~D3 LP M Circuit VCC VSS Bias Circuit To LSI VADJ VEE CFL HOT CFL Backlight CFL GND DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 11/18 5. Test No change on display and in operation under the following test condition. Conditions: No. Unless otherwise specified, tests will be conducted under the following condition. Temperature: 205C Humidity : 655%RH tests will be not conducted under functioning state. Parameter Conditions Notes 1 High Temperature Operating 60C2C, 96hrs (operation state) 2 Low Temperature Operating 0C2C, 96hrs (operation state) 1 3 High Temperature Storage 60C2C, 96hrs 2 4 Low Temperature Storage -20C2C, 96hrs 1,2 5 Damp Proof Test 40C2C,90~95%RH, 96hrs 1,2 6 Vibration Test Total fixed amplitude : 1.5mm 3 Vibration Frequency : 10~55Hz One cycle 60 seconds to 3 directions of X, Y, Z for each 15 minutes 7 Shock Test To be measured after dropping from 60cm high on the concrete surface in packing state. Dropping method corner dropping F E G B D C A 60cm A corner : once Edge dropping B,C,D edge : once Face dropping E,F,G face : once Concrete Surface Note 1 :No dew condensation to be observed. Note 2 :The function test shall be conducted after 4 hours storage at the normal Temperature and humidity after removed from the test chamber. Note 3 :Vibration test will be conducted to the product itself without putting it in a container. DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 12/18 6. Appearance Standards 6.1. Inspection conditions The LCD shall be inspected under 40W white fluorescent light. The distance between the eyes and the sample shall be more than 30cm. All directions for inspecting the sample should be within 45against perpendicular line. 45 6.2. Definition of applicable Zones X X=122.0mm Y=90.0mm Y A Zone B Zone C Zone Bezel Flame C Zone A Zone : Active display area B Zone : Area from outside of "A Zone" to validity viewing area C Zone : Rest parts A Zone + B Zone = Validity viewing area DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 13/18 6.3. Standards No. 1 Parameter Black and Criteria (1) Round Shape White Spots, Foreign Substances Zone Acceptable Number Dimension (mm) A B C D 0.1 * * * 0.1 < D 0.2 3 5 * 0.2 < D 0.25 2 3 * 0.25< D 0.3 0 1 * 0.3 < D 0 0 * D = ( Long + Short ) / 2 * : Disregard (2) Line Shape Zone X (mm) Acceptable Number Y (mm) A B C - 0.03 W * * * 2.0 L 0.05 W 3 3 * 1.0 L 0.1 W 3 3 * - 0.1 < W X : Length Y : Width In the same way (1) * : Disregard Total defects shall not exceed 5. 2 Air Bubbles (between glass & polarizer) Zone Dimension (mm) Acceptable Number A B C D 0.3 * * * 0.3 < D 0.4 3 * * 0.4 < D 0.6 2 3 * 0.6 < D 0 0 * * : Disregard Total defects shall not exceed 3. DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 14/18 No. 3 Parameter The Shape of Dot Criteria (1) Dot Shape (with Dent) 0.15 As per the sketch of left hand. (2) Dot Shape (with Projection) Should not be connected to next dot. (3) Pin Hole X (X+Y) / 2 0.2mm (Less than 0.1mm is no counted.) (4) Deformation (X+Y) / 2 0.2mm Y X Total acceptable number : 1/dot, 5/cell (Defect number of (4) : 1pc.) 4 Polarizer Scratches Not to be conspicuous defects. 5 Polarizer Dirts If the stains are removed easily from LCDP surface, the module is not defective. 6 7 Complex Foreign Black spots, line shaped foreign substances or air bubbles between Substance Defects glass & polarizer should be 5pcs maximum in total. Distance between D 0.2 : 20mm or more Different Foreign 0.2 < D : 40mm or more Substance Defects DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 15/18 7. Code System of Production Lot The production lot of module is specified as follows. Factory Number (Numeral) Factory Code (Alphabet) Production Week (1~5) Production Month (1~9, X, Y, Z) Production Year (Lower 2 digits) 8. Type Number The type number of module is specified on the back of module as follows. DMF-50840 NB-FW-AKE-AS Stamp or Seal Etching or Printing 9. Applying Precautions Please contact us when questions and/or new problems not specified in this specificationsarise. DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 16/18 10. Precautions Relating Product Handling The Following precautions will guide you in handling our product correctly. 1) Liquid crystal display devices 1. The liquid crystal display device panel used in the liquid crystal display module is made of plate glass. Avoid any strong mechanical shock. Should the glass break handle it with care. 2. The polarizer adhering to the surface of the LCD is made of a soft material. Guard against scratching it. 2) Care of the liquid crystal display module against static electricity discharge. 1. When working with the module, be sure to ground your body and any electrical equipment you may be using. We strongly recommend the use of anti static mats ( made of rubber ), to protect work tables against the hazards of electrical shock. 2. Avoid the use of work clothing made of synthetic fibers. We recommend cotton clothing or other conductivity-treated fibers. 3. Slowly and carefully remove the protective film from the LCD module, since this operation can generate static electricity. 3) When the LCD module alone must be stored for long periods of time: 1. Protect the modules from high temperature and humidity. 2. Keep the modules out of direct sunlight or direct exposure to ultraviolet rays. 3. Protect the modules from excessive external forces. 4) Use the module with a power supply that is equipped with an overcurrent protector circuit, since the module is not provided with this protective feature. 5) Do not ingest the LCD fluid itself should it leak out of a damaged LCD module. Should hands or clothing come in contact with LCD fluid, wash immediately with soap. 6) Conductivity is not guaranteed for models that use metal holders where solder connections between the metal holder and the PCB are not used. Please contact us to discuss appropriate ways to assure conductivity. 7) For models which use CFL: 1. High voltage of 1000V or greater is applied to the CFL cable connector area. Care should be taken not to touch connection areas to avoid burns. 2. Protect CFL cables from rubbing against the unit and thus causing the wire jacket to become worn. 3.The use of CFLs for extended periods of time at low temperatures will significantly shorten their service life. 8) For models which use touch panels: 1.Do not stack up modules since they can be damaged by components on neighboring modules. 2.Do not place heavy objects on top of the product. This could cause glass breakage. 9) For models which use COG,TAB,or COF: 1.The mechanical strength of the product is low since the IC chip faces out unprotected from the rear. Be sure to protect the rear of the IC chip from external forces. 2.Given the fact that the rear of the IC chip is left exposed, in order to protect the unit from electrical damage, avoid installation configurations in which the rear of the IC chip runs the risk of making any electrical contact. 10) Models which use flexible cable, heat seal, or TAB: 1.In order to maintain reliability, do not touch or hold by the connector area. DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 17/18 2.Avoid any bending, pulling, or other excessive force, which can result in broken connections. 11. Warranty This product has been manufactured to your company's specifications as a part for use in your company's general electronic products. It is guaranteed to perform according to delivery specifications. For any other use apart from general electronic equipment, we cannot take responsibility if the product is used in medical devices, nuclear power control equipment, aerospace equipment, fire and security systems, or any other applications in which there is a direct risk to human life and where extremely high levels of reliability are required. If the product is to be used in any of the above applications, we will need to enter into a separate product liability agreement. 1. We cannot accept responsibility for any defect, which may arise from additional manufacturing of the product (including disassembly and reassembly), after product delivery. 2. We cannot accept responsibility for any defect, which may arise after the application of strong external force to the product. 3. We cannot accept responsibility for any defect, which may arise due to the application of static electricity after the product has passed your company's acceptance inspection procedures. 4. When the product is in CFL models, CFL service life and brightness will vary according to the performance of the inverter used, leaks, etc. We cannot accept responsibility for product performance, reliability, or defect, which may arise. 5. We cannot accept responsibility for intellectual property of a third party, which may arise through the application of our product to your assembly with exception to those issues relating directly to the structure or method of manufacturing of our product. 6. Optrex will not be held responsible for any quality guarantee issue for defect products judged as Optrex-origin longer than 2 (two) years from Optrex production or 1(one) year from Optrex, Optrex America, Optrex Europe, Display LC delivery which ever comes later. DMF-50840NB-FW-AKE-AS (AS) No. 2001-0159 OPTREX CORPORATION Page 18/18