For more information, please visit the product page. date 10/29/2013 page 1 of 6 SERIES: PQD6-D DESCRIPTION: DC-DC CONVERTER FEATURES * * * * * * * * * * up to 6 W isolated output smaller package 4:1 input range (9~36 V, 18~75 V) single/dual regulated output 1,500 Vdc isolation continuous short circuit, over current protection six-sided shielded case temperature range (-40~85C) high efficiency at light load efficiency up to 88% input voltage MODEL output voltage output current output power ripple and noise1 efficiency typ (Vdc) range (Vdc) (Vdc) min (mA) max (mA) max (W) max (mVp-p) typ (%) PQD6-Q24-S3-D 24 9~36 3.3 75 1500 5 75 79 PQD6-Q24-S5-D 24 9~36 5 60 1200 6 75 83 PQD6-Q24-S12-D 24 9~36 12 25 500 6 75 87 PQD6-Q24-S15-D 24 9~36 15 20 400 6 75 88 PQD6-Q24-S24-D 24 9~36 24 12 250 6 75 88 PQD6-Q24-D5-D 24 9~36 5 30 600 6 75 83 PQD6-Q24-D12-D 24 9~36 12 12 250 6 75 87 PQD6-Q24-D15-D 24 9~36 15 10 200 6 75 88 PQD6-Q48-S3-D 48 18~75 3.3 75 1500 5 75 79 PQD6-Q48-S5-D 48 18~75 5 60 1200 6 75 83 PQD6-Q48-S12-D 48 18~75 12 25 500 6 75 87 PQD6-Q48-S15-D 48 18~75 15 20 400 6 75 88 PQD6-Q48-S24-D 48 18~75 24 12 250 6 75 88 PQD6-Q48-D5-D 48 18~75 5 30 600 6 75 83 PQD6-Q48-D12-D 48 18~75 12 12 250 6 75 87 PQD6-Q48-D15-D 48 18~75 15 10 200 6 75 88 Notes: 1. ripple and noise are measured at 20 MHz BW by "parallel cable" method PART NUMBER KEY PQD6 - QXX - XXX -D Base Number Output S = single D = dual Input Voltage cui.com Output Voltage Packaging Style DIP For more information, please visit the product page. CUI Inc SERIES: PQD6-D DESCRIPTION: DC-DC CONVERTER date 10/29/2013 page 2 of 6 INPUT parameter conditions/description operating input voltage 24 V input models 48 V input models start-up voltage 24 V input models 48 V input models surge voltage for maximum of 1 second 24 V input models 48 V input models filter pi filter min typ max units 9 18 24 48 36 75 Vdc Vdc 9 18 Vdc Vdc 50 100 Vdc Vdc 0.15 0.3 W typ max units -0.7 -0.7 no-load power consumption OUTPUT parameter conditions/description min line regulation full load, input voltage from low to high 0.2 0.5 % load regulation 5% to 100% load 0.5 1 % cross regulation dual output main output 50% load, secondary output 10%100% load 5 % 1 2 % 0.5 1.5 voltage accuracy voltage balance 1 dual output, balanced loads switching frequency 300 % KHz transient recovery time 25% load step change 300 500 s transient response deviation 25% load step change 3 5 % temperature coefficient 100% load 0.03 %/C max units Note: 1. For dual output models, unbalanced load can not exceed 5%. If 5% is exceeded, it may not meet all specifications. PROTECTIONS parameter conditions/description short circuit protection continuous, automatic recovery min typ over current protection 120 180 %lo over voltage protection 110 140 %Vo max units SAFETY AND COMPLIANCE parameter conditions/description isolation voltage for 1 minute at 1 mA max. 1,500 min isolation resistance at 500 Vdc 1,000 isolation capacitance input to output, 100 KHz/0.1 V typ Vdc M 1,000 safety approvals CE conducted emissions CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b) radiated emissions CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b) ESD IEC/EN61000-4-2, class B, contact 4kV radiated immunity IEC/EN61000-4-3, class A, 10V/m EFT/burst IEC/EN61000-4-4, class B, 2kV (external circuit required, see Figure 1-a) surge IEC/EN61000-4-5, class B, 2kV (external circuit required, see Figure 1-a) conducted immunity IEC/EN61000-4-6, class A, 3 Vr.m.s voltage dips & interruptions IEC/EN61000-4-29, class B, 0%-70% MTBF as per MIL-HDBK-217F @ 25C RoHS compliant 2011/65/EU 1,000,000 cui.com pF hours For more information, please visit the product page. CUI Inc SERIES: PQD6-D DESCRIPTION: DC-DC CONVERTER date 10/29/2013 page 3 of 6 ENVIRONMENTAL parameter conditions/description min max units operating temperature see derating curve -40 85 C -55 125 C 5 95 % 105 C storage temperature storage humidity non-condensing case temperature at full load, Ta=71C vibration 10~55 Hz for 30 min. along X, Y, and Z axis typ 10 G SOLDERABILITY parameter conditions/description max units hand soldering 1.5 mm from case for 10 seconds min typ 300 C wave soldering see wave soldering profile 260 C max units MECHANICAL parameter conditions/description min dimensions 25.40 x 25.40 x 11.70 (1.00 x 1.00 x 0.461 inch) case material aluminum alloy typ mm weight 14 g MECHANICAL DRAWING units: mm[inch] tolerance: 0.25[0.010] pin diameter tolerance: 0.10[0.004] pin height tolerance: 0.50[0.020] 11.70 [0.461] 4.10 [0.161] 1.50 [0.059] 5 4 3 Grid Size: 2.54mm x 2.54mm 1.00 [0.039] Front View 1 2 25.40 [1.000] 20.32 [0.800] PCB Layout Top View 5 PIN CONNECTIONS 2 25.40 [1.000] 4 20.32 [0.800] 3 1 5.08 [0.200] Bottom View cui.com PIN Single Output Dual Output 1 GND GND 2 Vin Vin 3 +Vo +Vo 4 NO PIN 0V 5 0V -Vo For more information, please visit the product page. CUI Inc SERIES: PQD6-D DESCRIPTION: DC-DC CONVERTER date 10/29/2013 page 4 of 6 DERATING CURVES Wave Soldering Profile Temperature Derating Curve Peak Temp. 260C Max. Wave Soldering Time 4 Sec. Max. 250 100 Load (%) Temperature (C) 200 10 Sec. Max. 150 100 80 60 Safe operating area 40 20 50 -40 0 -20 Time (sec.) 0 20 40 EMC RECOMMENDED CIRCUIT FUSE LDM1 LDM2 CY2 V in +Vo Vin + Figure 1 TVS MOV EUT C1 C0 GND (b) LOAD -Vo (0V) GND (a) CY1 Table 1 Recommended external circuit components Vin (Vdc) FUSE MOV 24 48 choose according to practical input current 10D560K 10D101K LDM1 56H 56H TVS SMCJ48A SMCJ90A C0 120F/50V 120F/100V C1 225K/50V 225K/100V LDM2 4.7H 4.7H CY1 102K/2000V 102K/2000V CY2 102K/2000V 102K/2000V TEST CONFIGURATION Figure 2 Table 2 Oscilloscope External components Lin Cin Current Probe 60 71 Ambient Temperature (C) DC DC Load Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance. cui.com Lin 4.7H Cin 220F, ESR < 1.0 at 100 KHz 85 100 For more information, please visit the product page. CUI Inc SERIES: PQD6-D DESCRIPTION: DC-DC CONVERTER date 10/29/2013 page 5 of 6 APPLICATION NOTES 1. Recommended circuit This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be tested under load (see Figure 3). If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR (see Table 3). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must be less than the maximum capacitive load (see Table 4). Figure 3 Dual Output Single Output Cin DC DC Cin DC Cin (F) Table 4 Cout (F) Single Vout (Vdc) Max. Capacitive Load (F) Dual Vout (Vdc) Max. Capacitive Load1 (F) 24 100 10 3.3 1800 -- -- 48 10~47 10 5 1000 5 470 12 100 12 100 15 100 15 100 24 47 -- -- Note: Note: 0V -Vo Table 3 Vin (Vdc) DC GND 0V GND +Vo Vin +Vo Vin 1. For each output. 1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may not meet all specifications listed. 2. Maximum capacitive load is tested at input voltage range and full load. 3. All specifications are measured at Ta=25C, humidity<75%, nominal input voltage and rated output load unless otherwise specified. cui.com For more information, please visit the product page. CUI Inc SERIES: PQD6-D DESCRIPTION: DC-DC CONVERTER date 10/29/2013 page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 06/17/2013 1.01 added CE safety approval 10/29/2013 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: CUI Inc.: PQD6-Q48-S5-D PQD6-Q48-S3-D PQD6-Q24-S3-D PQD6-Q24-S5-D PQD6-Q24-D12-D PQD6-Q48-D15-D PQD6-Q24-D15-D PQD6-Q48-S12-D PQD6-Q48-D12-D PQD6-Q24-D5-D PQD6-Q24-S15-D PQD6-Q24-S24-D PQD6-Q48-S15-D PQD6-Q48-S24-D PQD6-Q48-D5-D PQD6-Q24-S12-D