BAV170
DUAL SURFACE MOUNT LOW LEAKAGE DIODE
Features
• Surface Mount Package Ideally Suited for Automated Insertion
• Very Low Leakage Current
• Lead, Halogen and Antimony Free, RoHS Compliant
"Green" Device (Notes 3 and 4)
• Qualified to AEC-Q101 Standards for High Reliability
Mechanical Data
• Case: SOT-23
• Case Material: Molded Plastic. UL Flammability Classification
Rating 94V-0
• Moisture Sensitivity: Level 1 per J-STD-020D
• Terminals: Solderable per MIL-STD-202, Method 208
• Lead Free Plating (Matte Tin Finish annealed over Alloy 42
leadframe).
• Polarity: See Diagram
• Marking Information: See page 2
• Ordering Information: See Page 2
• Weight: 0.008 grams (approximate)
BAV170
Document number: DS30234 Rev. 10 - 2 1 of 3
www.diodes.com May 2008
© Diodes Incorporated
TOP VIEW
SOT-23
Internal Schematic
TOP VIEW
Maximum Ratings @TA = 25°C unless otherwise specified
Characteristic Symbol Value Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
VRRM
VRWM
VR 85 V
RMS Reverse Voltage VR(RMS) 60 V
Forward Continuous Current (Note 1) Single Diode
Double Diode IFM 215
125 mA
Repetitive Peak Forward Current IFRM 500 mA
Non-Repetitive Peak Forward Surge Current @ t = 1.0μs
@ t = 1.0ms
@ t = 1.0s IFSM 4.0
1.0
0.5 A
Thermal Characteristics
Characteristic Symbol Value Unit
Power Dissipation (Note 1) PD 250 mW
Thermal Resistance Junction to Ambient Air (Note 1) RθJA 500 °C/W
Operating and Storage Temperature Range TJ, TSTG -65 to +150 °C
Electrical Characteristics @TA = 25°C unless otherwise specified
Characteristic Symbol Min Typ Max Unit Test Condition
Reverse Breakdown Voltage (Note 2) V(BR)R 85 ⎯ ⎯ V IR = 100μA
Forward Voltage VF ⎯ ⎯
0.90
1.0
1.1
1.25
V
IF = 1.0mA
IF = 10mA
IF = 50mA
IF = 150mA
Leakage Current (Note 2) IR ⎯ ⎯ 5.0
80 nA
nA VR = 75V
VR = 75V, TJ = 150°C
Total Capacitance CT ⎯ 2 ⎯ pF VR = 0, f = 1.0MHz
Reverse Recovery Time trr ⎯ ⎯ 3.0 μs IF = IR = 10mA,
Irr = 0.1 x IR, RL = 100Ω
Notes: 1. Part mounted on FR-4 PC board with recommended pad layout, which can be found on our website at http://www.diodes.com/datasheets/ap02001.pdf.
2. Short duration pulse test used to minimize self-heating effect.
3. No purposefully added lead. Halogen and Antimony Free.
4. Product manufactured with Data Code V9 (week 33, 2008) and newer are built with Green Molding Compound. Product manufactured prior to Date
Code V9 are built with Non-Green Molding Compound and may contain Halogens or Sb2O3 Fire Retardants.
Please click here to visit our online spice models database.