Issued by Module Components Div, TAMURA CORPORATION Hall Effect Current Sensors L18P***D15 Series Features: Advantage: Open Loop type Printed circuit board mounting Integrated primary Voltage output Busbar version from 40A to 60A Insulated plastic case according to UL94V0 UL Recognition Excellent accuracy and linearity Wide nominal current range Low temperature drift Wide frequency bandwidth No insertion loss High Immunity To External Interference Optimised response time Current overload capability Specifications TA=25C, VCC=15V, RL=10k L18P003 L18P005 L18P010 L18P015 L18P020 L18P025 L18P030 L18P040 L18P050 L18P060 Symbol D15 D15 D15 D15 D15 D15 D15 D15 D15 D15 Parameters 3A If Primary nominal current 5A 10A 15A 20A 30A 40A 50A 60A If x 3 Ifmax Saturation current 25A Rated output voltage Vo 4V 0.040V (at If) 4V 0.050V (at If) Offset voltage1 Vof 0.040V (at If=0A) 0.050V (at If=0A) Output linearity2(0AIf) L 1% (at If) Power supply voltage VCC 15V 5% Consumption current Icc 15mA Response time3 tr 5s (at di/dt = If / s) Thermal drift of gain4 TcVo 0.1%/ C Thermal drift of offset TcVof 1.5mV/ C Hysteresis error (at If=0AIf0A) VOH Insulation voltage Vd AC3000V for 1minute (sensing current 0.5mA), primary secondary Insulation resistance RIS 500M (at DC500V), primary secondary TA -30C~+80C TS -40C~+85C Ambient operation temperature Ambient storage temperature 25mV 40mV 1 After removal of core hysteresis-- 2 Without offset --3 Time between 10% input current full scale and 90% of sensor output full scale -- Thermal drift of offset 4 Without Electrical Performances Frequency characteristic(L18P050D15) 6 15 10 2 Output voltage (V) Attenuation (dB) 4 Saturation characteristic(L18P050D15) 0 -2 -4 -6 5 0 -5 TA=25C Pulsed -8 -10 -10 0.1 1 10 Frequency characteristic(kHz) @ If=3Arms L18PXXXD15revD, March 2012 100 -15 -200 -150 -100 -50 0 50 Input current (A) Tamura reserve the right to modify its products in order to improve them without prior notice 100 150 200 Issued by Module Components Div, TAMURA CORPORATION Hall Effect Current Sensors L18P***D15 Series Mechanical dimensions The following, table references Terminal Number: 1: -VCC(-15V) 2: GND 3: +VCC(+15V) 4: VOUT 5: Primary input current (+) 6: Primary input current (-) Current XXX 3A 003 5A 005 10A 010 15A 015 20A 020 25A 025 30A 030 The following, table references A 0.6 0.8 1.1 1.4 1.6 1.6 1.6 Current XXX 40A 040 50A 050 60A 060 NOTES 1. Unit is mm 2. Tolerance is 0.5mm 3. Cover is optional parts. Primary :Busbar Electrical connection diagram -VCC +If +VCC -If RL = 10k GND VOUT UL Standard UL 508 , CSA C22.2 No.14 (UL FILE No.E243511) * For use in Pollution Degree 2 Environment. * Maximum Surrounding air temperature rating, 80C. Package & Weight Information nominal current Weight Pcs/box Pcs/carton Pcs/pallet 10A..60A 8g 100 600 12000 3A , 5A 8g 50 1200 28800 L18PXXXD15revD, March 2012 Tamura reserve the right to modify its products in order to improve them without prior notice