Technical Data Plastic bodied limit switch Series TI2 Description TI2-SU1Z HW RO13,5 Article number 6088171016 Operating symbol Fixed positioning with e.g. fixing screw M5 according to the standard DINENISO4762. Operating diagram On Off Tolerance: Operating point 0,25 mm; Actuating force 10 % Electrical Data Rated insulation voltage Conv. thermal current Rated operational voltage Utilization category Direct opening action Short-circuit protective device Protection class Ui Ithe Ue p 250 V AC 10 A AC / 2,5 A DC 240 V AC; 250 V DC AC-15, Ue/Ie 240 V / 3 A; DC-13, Ue/Ie 250 V / 0,27 A acc. to IEC/EN 60947-5-1, Annex K Fuse 6 A gG II, totally insulated BERNSTEIN AG . Hans-Bernstein-Strae 1 . 32457 Porta Westfalica . www.bernstein.eu Technical modifications and errors excepted. The technical datasheet corresponds to the technical state as of 2017-02-23 and will not be removed in case of changes. Page 1 of 2 6088171016 / 2084-17 Technical Data Mechanical data Enclosure Cover Actuator Ambient air temperature Contact type Mechanical life Switching frequency Assembly Connection Thermoplastic, glass fibre reinforced (UL 94-V0) Thermoplastic, glass fibre reinforced (UL 94-V0) Roller (thermoplastic) -30 C ... +80 C 1 NC, 1 NO (Zb) 3 x 106 operating cycles 100 / min. 2 x M4 or 2 x M5 fixed position for safety applications 4 screw connections (M3,5) Conductor cross-sections Solid: 0,5 ... 1,5 mm or Litz wire with ferrules: 0,5 ... 1,5 mm Cable entrance Weight Installation position Protection type 1 x M16 x 1,5 0,05 kg operator definable IP65 acc. to EN 60529; DIN VDE 0470 T1 Actuation The actuating device is preferably started from 2 sides. By loosening the 4 screws the actuation assembly can be rotated in 90 degree increments such that 4 actuation directions are possible. The actuation assembly is to be again fastened to the housing using the 4 screws. ID for safety engineering B10d 6 x 106 cycles Standards VDE 0660 T100, DIN EN 60947-1, IEC 60947-1 VDE 0660 T200, DIN EN 60947-5-1, IEC 60947-5-1 DIN EN ISO 13849-1 EU Conformity acc. to directive 2014/35/EU Approvals CCSAUS, A300, Q300 (same polarity) UL CCC Notes The degree of protection (IP code) specified applies solely to a property closed cover and the use of an equivalent cable gland with adequate cable. BERNSTEIN AG . Hans-Bernstein-Strae 1 . 32457 Porta Westfalica . www.bernstein.eu Technical modifications and errors excepted. The technical datasheet corresponds to the technical state as of 2017-02-23 and will not be removed in case of changes. Page 2 of 2 6088171016 / 2084-17